• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Neptune Branch Unit - APL
Neptune Branch Unit - APL

... 1. Shore station voltage is positive to isolate all loads (is +voltage really necessary?) 2. S4 is closed 3. Circuit could be energized from either end 4. Voltage across Z1 or Z2 is the power supply for the controller 5. S5 or S6 will close S1 or S2 6. Voltage across Z3 opens S4 after a delay 7. S1 ...
ECE 310 - Departments | Engineering at Illinois
ECE 310 - Departments | Engineering at Illinois

... In radial power systems the amount of fault current is limited by the fault distance from the power source: faults further done the feeder have less fault current since the current is limited by feeder impedance Radial power system protection systems usually use inverse-time overcurrent relays. Coor ...
Rechargeable Battery System (REBATEM)
Rechargeable Battery System (REBATEM)

... Major: Electrical Engineering ...
Design Project - Purdue Engineering
Design Project - Purdue Engineering

... errors should have a failure rate that is limited to 10-7. A high criticality failure is defined as one that has the potential to harm users. These kinds of errors should have a failure rate of no more than 10-9. The different pieces of our robotic arm have been assembled together using nuts and bol ...
Reliability and Safety Analysis
Reliability and Safety Analysis

INTRODUCTION
INTRODUCTION

... system is a balanced 3-phase AC. There are undesirable incidents that may disrupt normal conditions, as when the insulation of the system fails at any point. Then we say a fault occurs. ...
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE)
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE)

... order to determine Circuit Breaker (CB) capacity and protective relay performance. So, it is widely used both at the planning stage to select the right equipment and set up the protection system, and, later, at the operational stage to examine reinforcement schemes and switching arrangements, to upd ...
ppt
ppt

Intrduction - UniMAP Portal
Intrduction - UniMAP Portal

... signals to direct the entire computer system to carry out stored program instructions. • It does not execute program instructions; rather, it directs other parts of the system to do so. • Must communicate with both the arithmetic/logic unit and memory. ...
Chapter 1
Chapter 1

... Why study computer organization and architecture? – Design better programs, including system software such as compilers, operating systems, and device drivers. – Optimize program behavior. – Evaluate (benchmark) computer system performance. ...
CIRED 2003 Barcelona
CIRED 2003 Barcelona

in word formant
in word formant

... achieve these objectives, the number of facilitators who can lead CanSat projects in different regions around the world needs to be increased. This program is designed to provide future CanSat project leaders with a quality space engineering education course based on the Japanese CanSat program. To ...
Symbolic Error Metric Determination for Approximate Computing
Symbolic Error Metric Determination for Approximate Computing

... Approximate computing refers to techniques that relax the requirement of exact equivalence between the specification and the implementation [8]. There exist several applications, such as media processing (audio, video, graphics, and image), recognition, and data mining, that tolerate acceptable thou ...
Low Voltage Power Circuit Breaker
Low Voltage Power Circuit Breaker

... is to provide protection to circuit components and equipment. A short-time delay (STD) setting on a circuit breaker can negate the function of protecting the circuit components. A low voltage power circuit breaker with a short-time delay and without instantaneous trip, permits a fault to flow for th ...
AlarmSense PLUS Panel Data Sheet
AlarmSense PLUS Panel Data Sheet

... end user of a fire alarm panel. The colour coded buttons and the 3 step silence functionality gives non-technical people the confidence to correctly manage their fire alarm system. All inputs and outputs are fully programmable and there are options to have delays and coincidence attributes to the ou ...
Electrical and Electronics Engineering Department
Electrical and Electronics Engineering Department

... Group B: (40 Marks: MCQ) This Section will cover fundamentals from B. Tech Syllabus in Electrical and Electronics Engineering. Group C: (30 Marks: Descriptive) Candidate is required to answer one of the groups. However, his/her selection may not be limited to that specialization only. ...
Series and parallel circuits
Series and parallel circuits

... Lighting circuits are usually connected in either series or parallel. The circuit below shows a basic circuit using two lamps and a single cell connected in series. ...
PDF Version(81KB)
PDF Version(81KB)

... Smaller, simpler design for inverter systems in air conditioners and industrial applications TOKYO, May 7, 2015 – Mitsubishi Electric Corporation (TOKYO: 6503) announced today the launch of DIPIPM+, new models in its DIPIPMTM series of inverter applications featuring loading converter and brake circ ...
.Power`World - A Software Approach to Transmission Line Fault
.Power`World - A Software Approach to Transmission Line Fault

... he steady state operating mode of a power system is balanced 3-phase ac. However due to sudden external or internal changes in the system, this condition is disrupted. When the insulation of the system fails at one or more points or a conducting object comes in contact with a live point, a short cir ...
PS-CCU Power Supply
PS-CCU Power Supply

... The PS-CCU is a universal power supply designed for use with DDS 5900 Digital Discussion Systems and DCS 6000 Digital Conference Systems. It can be used in any country simply by connecting the regional IEC cable. ...
A Method to Enhance Ground
A Method to Enhance Ground

Technical Research Paper “Microcontroller based Fault Detector”
Technical Research Paper “Microcontroller based Fault Detector”

...  The relay is then connected to the load. In our device we have used a lamp load to show the operation of relay.  Now, the AC supply is used to get a 3 phase looped supply by a switch named R Y B in the project. It is used to get a three phase supply done by looping the three terminals of the swit ...
Arc Fault Circuit Interrupter Explained
Arc Fault Circuit Interrupter Explained

... result in almost four times the power and heat in loads. With such overheating, some loads can reach self-ignition temperature in less than 10 minutes. Power fault circuit interrupters (PFCIs) are designed to prevent fires caused by excess voltage across loads. Voltage-trip circuit breakers detect e ...
Datasheet - Hans Stutvoet MSc
Datasheet - Hans Stutvoet MSc

... After this training course power engineers will know the principle of operation of an automatic voltage regulator (AVR), an excitation system and a power management system (PMS). In this unique course we will pay attention to applications from simple gensets, to larger generators and to complex syst ...
Digital Rotor Telemetry Short Form Catalog
Digital Rotor Telemetry Short Form Catalog

... Excellent rotor-to-pickup-coil movement tolerance High data integrity and noise immunity ...
< 1 ... 238 239 240 241 242 243 244 245 246 ... 256 >

Fault tolerance



Fault tolerance is the property that enables a system to continue operating properly in the event of the failure of (or one or more faults within) some of its components. If its operating quality decreases at all, the decrease is proportional to the severity of the failure, as compared to a naively designed system in which even a small failure can cause total breakdown. Fault tolerance is particularly sought after in high-availability or life-critical systems.A fault-tolerant design enables a system to continue its intended operation, possibly at a reduced level, rather than failing completely, when some part of the system fails. The term is most commonly used to describe computer systems designed to continue more or less fully operational with, perhaps, a reduction in throughput or an increase in response time in the event of some partial failure. That is, the system as a whole is not stopped due to problems either in the hardware or the software. An example in another field is a motor vehicle designed so it will continue to be drivable if one of the tires is punctured. A structure is able to retain its integrity in the presence of damage due to causes such as fatigue, corrosion, manufacturing flaws, or impact.Within the scope of an individual system, fault tolerance can be achieved by anticipating exceptional conditions and building the system to cope with them, and, in general, aiming for self-stabilization so that the system converges towards an error-free state. However, if the consequences of a system failure are catastrophic, or the cost of making it sufficiently reliable is very high, a better solution may be to use some form of duplication. In any case, if the consequence of a system failure is so catastrophic, the system must be able to use reversion to fall back to a safe mode. This is similar to roll-back recovery but can be a human action if humans are present in the loop.