• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Trouble - MacMate
Trouble - MacMate

... Often not obvious disconnected or break. Often connection to a device where the open or break occurs. May be from improper stripping - nick or twisted too tightly under a wire nut (Marrette®). ...
1 Introduction to the course and background of
1 Introduction to the course and background of

... Control theory and control engineering study control systems, their performance, robustness, and stability. In this course, we focus on commonly-known controllers such as proportional-integralderivative (PID) control. It is worth knowing that multiple approaches for classical controller synthesis ex ...
ELTC 101 - Muskegon Community College
ELTC 101 - Muskegon Community College

... Identify inductors in series and parallel and understand how to calculate total inductance when inductors are in combination List and explain the fixed and variable types of inductors Describe the basic operation of a transformer Explain the differences between a loaded and unloaded transformer List ...
Chapter 31
Chapter 31

... You should know how to compute the current given the generator emf. If = m sin ωdt, then i = I sin(ωdt - φ), where I = m/Z and tan φ = (XL - XC)/R. Think of φ as a phase difference. That is, if = m sin(ωdt + α), then i = I sin(ωdt + α - φ). Given the current, you should know how to compute the poten ...
Sikorsky Aircraft - ECE Senior Design
Sikorsky Aircraft - ECE Senior Design

FAC-010-2 1 System Operating Limits Methodology for the Planning
FAC-010-2 1 System Operating Limits Methodology for the Planning

IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE)
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE)

... Transient stability issues which are also known as the first swing stability are among the important practical concerns in Nigeria power system operation and planning studies. Transient stability assessment which entails the investigation of large disturbances is part of an essential requirements fo ...
Thevenin Theorem
Thevenin Theorem

Modeling of Distributed Generators in 13 Nodes IEEE Test Feeder
Modeling of Distributed Generators in 13 Nodes IEEE Test Feeder

... The distributed generation is based on the production of electricity located near the demanding load and frequently installed in the same building. It considers a wide variety of technologies depending on the availability. Sometimes, this distribution is named “disruptive” due to its propensity to a ...
Motor and Pump Protection
Motor and Pump Protection

... Programming the Model 777 is an easy four step process: 1) Rotate the MODE SELECT switch to the parameter to be programmed; 2) Depress and hold the RESET/PROGRAM button; 3) Rotate the DISPLAY/PROGRAM dial to the desired setting as shown in the LED display; and 4) Release the RESET/PROGRAM button. An ...
DTC C1236 Low System Supply Voltage
DTC C1236 Low System Supply Voltage

... DTC C1236 monitors the voltage level available to the EBTCM controller. If the voltage drops below 11.4 volts, full performance of the ABS system is not guaranteed. During ABS operation, there are several current requirements that will cause battery voltage at the EBTCM to drop. As a result, voltage ...
a-isometer® ir420 - Bender Benelux BV
a-isometer® ir420 - Bender Benelux BV

Computer Components - 4040
Computer Components - 4040

Simulating Electromagnetic Interactions in High Power Density
Simulating Electromagnetic Interactions in High Power Density

... discretization is required, resulting in a high number of elements to be calculated. Although the FEM can be applied in 2D and 3D, the number of elements rises disproportional in 3D setups, easily exceeding the calculation capability of nowadays computers. The first possibility to reduce simulation ...
semiconductor circuit templates
semiconductor circuit templates

... Click within the blue frame to access the control panel. Only use the control panel (at the bottom of screen) to review what you have seen. When using your mouse, make sure you click only when it is within the blue frame that surrounds each slide. ...
TD class note 3
TD class note 3

Lecture note from 21-26 Lecture 21 Problem Solving 1) A single
Lecture note from 21-26 Lecture 21 Problem Solving 1) A single

EE2003 Circuit Theory
EE2003 Circuit Theory

... 13.1 What is a transformer? (1) • It is an electrical device designed on the basis of the concept of magnetic coupling • It uses magnetically coupled coils to transfer energy from one circuit to another • It is the key circuit elements for stepping up or stepping down ac voltages or currents, imped ...
SCHEMATIC OF GRAYMARK 808 POWERED BREADBOARD
SCHEMATIC OF GRAYMARK 808 POWERED BREADBOARD

... indicate a low resistance and the other should indicate a very high resistance. Measure the base-collector diode in the same way, reversing the leads for the second measurement. Again one polarity should indicate high, and the other low resistance. Both diodes connections in a transistor must be tes ...
Circuit Breakers
Circuit Breakers

- UTas ePrints
- UTas ePrints

... that wind turbines, similar to conventional power plants, must be able to stay connected to the grid during fault. This operational behaviour is known as fault ride-through (FRT) capability [1]. Nowadays, doubly-fed induction generator (DFIG) based wind turbines are widely used because of many salie ...
Unplanned Outages: Four Keys to Assessing Risk and
Unplanned Outages: Four Keys to Assessing Risk and

... Assessing the condition of high voltage circuit breakers involves weighing the number of operations, the magnitude of faults to which it was exposed, and its estimated life. With this information, it can be determined which breakers are currently most prone to failure. A breaker‟s priority also fact ...
Technical Series, Edition 1
Technical Series, Edition 1

... Group 2 Rooms and areas categorized as Group 2 are used for diagnosis and patient therapy where the type of medical treatment may be directly or indirectly dangerous for the patient. In parts of Group 2 and Group 1 areas there are IT isolating transformers which ensure an additional safety standard. ...
STP 3 & 4 7.8  COL License Information
STP 3 & 4 7.8 COL License Information

... voltages between system units. For ABWR safety systems, the problem has been reduced by using fiber optic cables as the transmission medium for most critical signals. While the cables may contain metallic supporting members or protective shields, these are not electrically connected to any equipment ...
AMP215_Switchgear_final_130813 - International Atomic Energy
AMP215_Switchgear_final_130813 - International Atomic Energy

... years like required in KTA 3705 [3]). Frequency and scope of activities should be based on the manufactures recommendations. Functional tests should be performed periodically (and at least after each maintenance measure) on breakers and protection relays. Frequency and scope of tests should be based ...
< 1 ... 130 131 132 133 134 135 136 137 138 ... 256 >

Fault tolerance



Fault tolerance is the property that enables a system to continue operating properly in the event of the failure of (or one or more faults within) some of its components. If its operating quality decreases at all, the decrease is proportional to the severity of the failure, as compared to a naively designed system in which even a small failure can cause total breakdown. Fault tolerance is particularly sought after in high-availability or life-critical systems.A fault-tolerant design enables a system to continue its intended operation, possibly at a reduced level, rather than failing completely, when some part of the system fails. The term is most commonly used to describe computer systems designed to continue more or less fully operational with, perhaps, a reduction in throughput or an increase in response time in the event of some partial failure. That is, the system as a whole is not stopped due to problems either in the hardware or the software. An example in another field is a motor vehicle designed so it will continue to be drivable if one of the tires is punctured. A structure is able to retain its integrity in the presence of damage due to causes such as fatigue, corrosion, manufacturing flaws, or impact.Within the scope of an individual system, fault tolerance can be achieved by anticipating exceptional conditions and building the system to cope with them, and, in general, aiming for self-stabilization so that the system converges towards an error-free state. However, if the consequences of a system failure are catastrophic, or the cost of making it sufficiently reliable is very high, a better solution may be to use some form of duplication. In any case, if the consequence of a system failure is so catastrophic, the system must be able to use reversion to fall back to a safe mode. This is similar to roll-back recovery but can be a human action if humans are present in the loop.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report