• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Pulse Oximetry - Cornell ECE
Pulse Oximetry - Cornell ECE

... and Implantable Body Sensor Networks (2009).  Basu, Arindam, Ryan Robucci, and Paul Hasler. "A Low-Power, Compact, Adaptive Logarithmic Transimpedance Amplifier Operating over Seven Decades of Current." IEEE Transactions on Circuits and Systems 54.10 (2007).  Lopez-Martin, Antonio J., and Alfonso ...
Inlet Air Temperature (IAT) Sensors
Inlet Air Temperature (IAT) Sensors

... the voltage of the sensor. The ECU assesses the voltage value because it is in direct relation to the inlet air temperature. That means low temperature high voltage, high temperature low voltage. ...
Experiment FT2
Experiment FT2

... production of mutually induced e.m.f in the secondary coil. A mutual inductance M may be defined to quantify the ability of one coil to produce an e.m.f in a nearby coil by induction when the current in the first coil changes. This action is reciprocal, i.e., the second coil can also induce an e.m.f ...
1EDI EiceDRIVER™ Compact 300 mil
1EDI EiceDRIVER™ Compact 300 mil

... 1EDI EiceDRIVER™ Compact 300 mil 1200 V galvanically isolated single-channel wide body gate driver IC family Complementing our successful 1EDI EiceDRIVER™ Compact family, we now offer our compact drivers in a wide body package for increased creepage distance, improved thermal behavior, and optimized ...
DOC
DOC

...  Again show your instructor and make plots in your notebook of the time and frequency domain data. ...
Evaluates:  MAX4450 MAX4450 Evaluation Kit General Description Features
Evaluates: MAX4450 MAX4450 Evaluation Kit General Description Features

... The MAX4450 EV kit circuit’s output bandwidth is 5.25MHz at -3dB point and has an insertion loss greater than 20dB at 13.5MHz and greater than 40dB at 27MHz. Figure 5 illustrates the Signal Gain vs. Input Signal Frequency of the EV kit’s filtering circuit. The group delay variation across the bandwi ...
A) Resistance, Voltage and Current Measurement
A) Resistance, Voltage and Current Measurement

... An oscilloscope is easily the most useful instrument available for testing circuits because it allows you to see the signals at different points in the circuit. The best way of investigating an electronic system is to monitor signals at the input and output of each system block, checking that each b ...
moplt124
moplt124

... as the length of the bunches that we want to inject as well as how many turns we want to keep in the ring before extraction can be changed. The voltage monitor of the high voltage switch of one of the chopper plates is used to trigger the acquisition of the beam profiles in the oscilloscope. The dc ...
1 LABORATORY AUTOMATION: DECAY OF A CAPACITOR
1 LABORATORY AUTOMATION: DECAY OF A CAPACITOR

... The apparatus is interfaced to a National Instruments Lab PC+ DAQ (digital acquisitions) board which is installed in slot 3 of the PC bus. Windows95 assigned a DMA (direct memory access) channel 1, an IRQ (interrupt request) channel 5, and a base I/O address of hex 140 to the device. You will not us ...
Ground Current Measurement
Ground Current Measurement

... Instrumentation amplifiers are not, of course, free from noise. The AD620 has a little over 1 µV r.m.s. input referred noise when used with a gain of 1,000. This means that the oscilloscope trace will not be a fine line but a fuzzy line several mV wide (referred to the oscilloscope input). Neverthel ...
2: Audio Basics
2: Audio Basics

... enough if the signal always used the full range. But signal varies in loudness.  If full range is used for loud parts, quiet parts will suffer from bad quantization noise (only a few levels used).  If full range is used for quiet parts, loud parts will clip, ...
SFX-424G Synchronous Clock Generators Applications
SFX-424G Synchronous Clock Generators Applications

... The SFX-424G is a high precision frequency translator that translates up to four inputs from 8 kHz to 100MHz, to output frequencies between 8 MHz and 800 MHz. The SFX-424G supports all major FEC rates such as 15/14, 255/237 etc. SFX-424G is well suited for use in line cards, service termination ca ...
Capacitors
Capacitors

... the capacitor to charge and discharge to these values. But if the time constant is several times ...
User Manual Rev. 01a
User Manual Rev. 01a

... Because there is always some capacitance between scope input and ground probe needs to be calibrated to achieve better measurement results for high frequency signals. This can be done with the help of the built-in test signal. To do this please follow the steps below. ...
Problems to resolve:
Problems to resolve:

... The AD831 has an output amplifier built in that we are not using. I asked tech support if we could somehow shut the amp off in order to save current, but he said that it was not possible. He also said that a resistor should be placed in between the VFB and Out pins in order to provide feedback (so t ...
Electret Microphone/Oscilloscope Demo
Electret Microphone/Oscilloscope Demo

... 1. Hold a tuning fork to the microphone, and observe the sinusoidal output. Then make a vocal sound. The waveform from a human voice will not be sinusoidal, and will change with the quality of the sound (e.g., if the vowel is open mouthed, the waveform will be jagged, if the lips are closed, the wav ...
Capacitor Self
Capacitor Self

A High Linearity Darlington Intermediate Frequency (IF
A High Linearity Darlington Intermediate Frequency (IF

RTCA SC-135 and EUROCAE WG-14
RTCA SC-135 and EUROCAE WG-14

... structure). In addition, the hi-pot test is applicable for electrical devices that are electrically isolated from case and local airframe grounds. In these cases, the interface signal and return wiring must be routed together (e.g. twisted pair) in the intended installation such that an insignifican ...
High-speed Sample and Hold using Low Temperature
High-speed Sample and Hold using Low Temperature

... Figure 2 shows a timing diagram for the measurement. The pump pulse closes the MSM switch, sampling the input signal onto the hold capacitor. The probe pulse then samples the voltage across the hold capacitor via the electro-optic crystal. A reset pulse placed during the zero period of the input sig ...
Episode 123 - Teaching Advanced Physics
Episode 123 - Teaching Advanced Physics

... the earthed lead of the CRO (often black) is connected to the earthed terminal of the supply (often yellow), or you will short out the signal generator through the CRO. Set the frequency of the signal generator to about 500 Hz and its amplitude to about 3 V. Adjust the oscilloscope until you have a ...
BDTIC BB439...
BDTIC BB439...

... the device, Infineon Technologies hereby disclaims any and all warranties and liabilities of any kind, including without limitation, warranties of non-infringement of intellectual property rights of any third party. ...
Alternating Current Applet Activity
Alternating Current Applet Activity

... The root-mean-square (rms) value of an alternating current (or voltage) is that value of the direct current (or voltage) that dissipates power in a resistor at the same rate. In this activity you will determine the rms voltage of an ac resistor circuit and use it to show that its equivalent dc value ...
SNA-286 DC-6.0  GHz,  Cascadable GaAs  MMIC  Amplifier Product Description
SNA-286 DC-6.0 GHz, Cascadable GaAs MMIC Amplifier Product Description

... 1 uF ...
A short user manual by OH6MLD
A short user manual by OH6MLD

... both RX and TX VCO’s must be retuned. Tuning is done by adjusting the VCO/PLL trimmer capacitor, seen from the front, under the cover in lower part of the radio. Both trimmers are marked with appropriated labels, while having also the test point marked. Tuning must be done in the lower end of the ba ...
< 1 ... 89 90 91 92 93 94 95 96 97 ... 106 >

Tektronix analog oscilloscopes



Tektronix vintage analog oscilloscopes technologies and evolution.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report