• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Experiment 2b: TVS, Simulation using Scope
Experiment 2b: TVS, Simulation using Scope

... g. Try making a voltage divider of this ratio: 10:1 using the two capacitor values from the previous experiment in parallel with a set of two resistors you selected in the DC experiments. This voltage divider would be similar to the voltage divider made by anyone who uses a 10X probe with an oscillo ...
DATA  SHEET TDA8010M; TDA8010AM Low power mixers/oscillators for satellite tuners
DATA SHEET TDA8010M; TDA8010AM Low power mixers/oscillators for satellite tuners

... The TDA8010M; TDA8010AM are integrated circuits that perform the mixer/oscillator function in satellite tuners. The devices include a gain controlled IF amplifier that can directly drive two single-ended SAW filters or a differential SAW filter using a three function switchable output. They contain ...
ADA4412-3 数据手册DataSheet 下载
ADA4412-3 数据手册DataSheet 下载

... For single-supply applications (VS− = GND), the input voltage range extends from 100 mV below ground to within 2.0 V of the most positive supply. Each filter input includes level-shifting circuitry. The level-shifting circuitry adds a dc component to ground-referenced input signals so that they can ...
HMC733LC4B, WIDEBAND MMIC VCO w
HMC733LC4B, WIDEBAND MMIC VCO w

ADL5391 DC to 2.0 GHz Multiplier Data Sheet (Rev. 0)
ADL5391 DC to 2.0 GHz Multiplier Data Sheet (Rev. 0)

... The ADL5391 draws on three decades of experience in advanced analog multiplier products. It provides the same general mathematical function that has been field proven to provide an exceptional degree of versatility in function synthesis. VW = α × (VX × VY)/ 1 V + VZ The most significant advance in t ...
AD8074
AD8074

... The AD8074 (G = +1) and AD8075 (G = +2) are triple-channel, high-speed buffers with TTL-compatible output enable control. Optimized for buffering RGB (red, green, blue) video sources, the devices have high peak slew rates, maintaining their bandwidth for large signals. Additionally, the buffers are ...
Offset Error
Offset Error

... CONVERSION TIME - is the time required for a complete measurement by an analog-to-digital converter. Since the Conversion Time does not include acquisition time, multiplexer set up time, or other elements of a complete conversion cycle, the conversion time may be less than the Throughput Time. Numbe ...
types of defibrillators
types of defibrillators

... Testing Defibrillators A dummy load is connected across the defibrillator electrodes Discharge is observed 50 ohm resistance is taken as human resistance connected in series with a low value resistor. Neon light is connected with low value resistor and lights when defibrillator is discharged ...
Arduino Section I
Arduino Section I

... One of the most useful tools in an engineer or Maker’s toolkit. The three most important thing to remember: ...
Optical Communications Laboratory
Optical Communications Laboratory

... Look at the falling edge on the 50ns time scale with the function generator waveform superimposed, and attach a 47ρF capacitor across R2. Observe what happens. This is known as a speed-up capacitor, and decreases the storage time by storing charge to neutralize the base charge "just after turn-off". ...
LABORATORY 1 WRITEUP - PHYSICS 517/617 Prof. L. S. Durkin
LABORATORY 1 WRITEUP - PHYSICS 517/617 Prof. L. S. Durkin

... The capacitance measurements of Table 8 do not seem very consistent. There seems to be greater than a 10 % difference in the answer when I change my C1 value. Even more shocking is the difference with the manual for the scope which claims and internal capacitance of 35 pF. To check the internal capa ...
Adaptive signal sampling for high throughput, broadband
Adaptive signal sampling for high throughput, broadband

... has nothing to do with electrical characterization of a material in time domain. If a system is time invariant and linear with respect or current/voltage characteristics, time and frequency domain can be converted into each other using several kind of transformation where the most popular one, the F ...
Biofeedback Tension Monitor
Biofeedback Tension Monitor

Representations of any two different signals
Representations of any two different signals

... Weighted Summer with Coefficients of Both Signs ...
AD8004
AD8004

... The AD8004 is a member of a new family of high speed currentfeedback (CF) amplifiers offering new levels of bandwidth, distortion, and signal-swing capability vs. power. Its wide dynamic range capabilities are due to both a complementary high speed bipolar process and a new design architecture. The ...
ece2201_lab6_modified
ece2201_lab6_modified

... L18. Adjust the function generator to produce a 0.5V peak (1V peak-to-peak) sine wave at 1kHz. This should produce a 10mV peak-to-peak sine wave at Vin. Display vS and vOUT1 on oscilloscope channel 1 and 2. Use DC coupling, set both channels to 2V/div, and adjust the vertical position so that 0V (gr ...
a Complete 700 ns Sample-and-Hold Amplifier AD781*
a Complete 700 ns Sample-and-Hold Amplifier AD781*

... circuitry with low power CMOS to provide an accurate, high speed, low power SHA. The AD781 is specified for three temperature ranges. The J grade device is specified for operation from 0°C to +70°C, the A grade from –40°C to +85°C and the S grade from –55°C to +125°C. The J and A grades are availabl ...
AD831 数据手册DataSheet 下载
AD831 数据手册DataSheet 下载

... DC Coupled Using Dual Supplies All Ports May Be DC Coupled No Lower Frequency Limit—Operation to DC User-Programmable Power Consumption ...
IS2515571559
IS2515571559

... such as wireless LAN transceivers, in the read channels of magnetic storage devices using digital data detection, and many others . In the past, highspeed A/D converters required for these applications in the sampling rate range above 5 Msample/sec (MS/s) with 8 to 12 bit of resolutions have consume ...
C. Wavelength
C. Wavelength

AUDIO_TERMS
AUDIO_TERMS

... Digital audio can be copied from one digital device to another without any loss of information, unlike analog recording, where information is lost and noise introduced with every copy. Even the best analog systems lose about 3dB of signal-to-noise ratio when a copy is recorded. After several generat ...
BFP540FESD
BFP540FESD

... ma = |S21e / S12e| (k-(k²-1) ), Gms = |S21e / S12e| 2IP3 value depends on termination of all intermodulation frequency components. ...
Dual 2GHz Balanced Mixer with Low Side LO Buffer, ADL5356
Dual 2GHz Balanced Mixer with Low Side LO Buffer, ADL5356

... mixer cores along with integrated RF and LO balancing circuitry to enable single-ended operation. The ADL5356 incorporates two RF baluns allowing for optimal main and diversity mixer performance over a 1700 to 2200 MHz RF input frequency range using low-side LO injection. (For a high side injection ...
AD8074/AD8075 500 MHz, G = +1 and +2 Triple
AD8074/AD8075 500 MHz, G = +1 and +2 Triple

... The AD8074 (G = +1) and AD8075 (G = +2) are triple-channel, high-speed buffers with TTL-compatible output enable control. Optimized for buffering RGB (red, green, blue) video sources, the devices have high peak slew rates, maintaining their bandwidth for large signals. Additionally, the buffers are ...
Lecture Notes - Signals and Spectra File
Lecture Notes - Signals and Spectra File

... • The waveform is a continuous function of time • The waveform has a finite peak value • The waveform has only real values. That is, at any time, it cannot have a complex value a+jb, where b is nonzero. Eeng360 ...