• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
994-0089 D400 Substation Data Manager User`s Manual.book
994-0089 D400 Substation Data Manager User`s Manual.book

Intel® Core™2 Extreme Processor QX9000Δ Series, Intel® Core™2
Intel® Core™2 Extreme Processor QX9000Δ Series, Intel® Core™2

Datasheet: Intel® Pentium® 4 Processor 6x1 Sequence Datasheet
Datasheet: Intel® Pentium® 4 Processor 6x1 Sequence Datasheet

... The Intel® Pentium® 4 Processor 6x1 sequence may contain design defects or errors known as errata which may cause the product to deviate from published specifications. Contact your local Intel sales office or your distributor to obtain the latest specifications and before placing your product order. ...
Quad-Core Intel® Xeon® Processor 5400 Series
Quad-Core Intel® Xeon® Processor 5400 Series

Quad-Core Intel® Xeon® Processor 5400 Series Datasheet
Quad-Core Intel® Xeon® Processor 5400 Series Datasheet

Intel Processor A100 and A110 on 90 nm Process with 512
Intel Processor A100 and A110 on 90 nm Process with 512

... Intel processor numbers are not a measure of performance. Processor numbers differentiate features within each processor family, not across different processor families. See http://www.intel.com/products/processor_number for details. Over time processor numbers will increment based on changes in clo ...
Dual-Core Intel® Xeon® Processor 5100 Series Datasheet
Dual-Core Intel® Xeon® Processor 5100 Series Datasheet

Dual-Core Intel® Xeon® Processor 5200 Series
Dual-Core Intel® Xeon® Processor 5200 Series

DMMS 300+/350/425 - Electro Industries
DMMS 300+/350/425 - Electro Industries

... 3.1: Important Considerations When Installing Meters Please read the following sections carefully for important safety information regarding installation and hookup of the meter. This meter is rated as “permanently installed equipment” and must be installed in non-accessible areas only, e.g. control ...
USER`S GUIDE InfraStruXure Manager
USER`S GUIDE InfraStruXure Manager

TruDim® Dimmable CFL Specification
TruDim® Dimmable CFL Specification

Technology Comparison for Large Last-Level Caches
Technology Comparison for Large Last-Level Caches

PA-800 Series Hardware Reference
PA-800 Series Hardware Reference

Power Management Selection Guide 2015 01_00
Power Management Selection Guide 2015 01_00

HOBO® Plug Load Logger (UX120-018) Manual
HOBO® Plug Load Logger (UX120-018) Manual

Xilinx UG394 Spartan-6 FPGA Power Management User Guide
Xilinx UG394 Spartan-6 FPGA Power Management User Guide

FTB 312-3 - Flash Technology
FTB 312-3 - Flash Technology

... precaution, exercise extreme caution at all times when you expose circuits and components, and when you operate, maintain, or service this equipment. ...
Fixed Resistors - Passive Components 1773442-9
Fixed Resistors - Passive Components 1773442-9

... technology in Thin Film (Metal Film), Wirewound and Thick Film technologies. Products are available in both surface mount and leaded styles ranging from small 0402 size chip resistors to 14 watt leaded devices, thereby combining precision technologies and ...
Planning of Electric Power Distribution
Planning of Electric Power Distribution

... spaces and appropriately designed facilities in association with or in structures Regarding the planning concept for power supply, it is not only imperative to observe standards and regulations, it is also important to discuss and clarify economic and technical interrelations. To this end electric e ...
P84905
P84905

... The POWERPATH NAC Extender Power Supply is available in two models: the PS-8 and the PS-6. The PS-8 differs from the PS-6 in the NAC output current and in the enclosure size and the PS-8 enclosure can mount up to two addressable control modules. All other features, indicators and capacities are the ...
Powerware BladeUPS for Data Centers, 12kW single system
Powerware BladeUPS for Data Centers, 12kW single system

How to become a KNX certified training centre
How to become a KNX certified training centre

P84905-002A
P84905-002A

... charging up to 33 Amp/Hour (Ahr) of battery backup. The PS-8-LP’s NAC outputs can also be used as UL-1481 Compliant power supply outputs. When configured this way, the maximum continuous current rating is 3 Amps per power supply output and 4 Amps maximum total current for all continuous duty power s ...
CONVENTIONAL FIRE PANELS
CONVENTIONAL FIRE PANELS

submittals for release stand-alone clc systems
submittals for release stand-alone clc systems

... help you complete these forms if you have ANY questions. CANCELLATION POLICY: If a Start-Up Request Form has been submitted and confirmed, and appropriate travel arrangements have been made (ie. flight, train, car rental, hotel, etc.) requestee will be held responsible for all associated cancellatio ...
1 2 3 4 5 ... 159 >

Standby power

Standby power, also called vampire power, vampire draw, phantom load, or leaking electricity (""phantom load"" and ""leaking electricity"" are defined technical terms with other meanings, adopted for this different purpose), refers to the electric power consumed by electronic and electrical appliances while they are switched off (but are designed to draw some power) or in a standby mode. This only occurs because some devices claimed to be ""switched off"" on the electronic interface, but are in a different state from switching off at the plug, or disconnecting from the power point, which can solve the problem of standby power completely. In fact, switching off at the power point is effective enough, there is no need to disconnect all devices from the power point. Some such devices offer remote controls and digital clock features to the user, while other devices, such as power adapters for disconnected electronic devices, consume power without offering any features (sometimes called no-load power). All of the above examples, such as the remote control, digital clock functions and—in the case of adapters, no-load power—are switched off just by switching off at the power point. However, for some devices with built-in internal battery, such as a phone, the standby functions can be stopped by removing the battery instead.In the past, standby power was largely a non-issue for users, electricity providers, manufacturers, and government regulators. In the first decade of the twenty-first century, awareness of the issue grew and it became an important consideration for all parties. Up to the middle of the decade, standby power was often several watts or even tens of watts per appliance. By 2010, regulations were in place in most developed countries restricting standby power of devices sold to one watt (and half that from 2013).
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report