Ethernet Power Supply Controller
... The intent was to provide as much commonality as possible with the Bitbus controller The performance was to be equal or better then the Bitbus chassis Should not cost more then Bitbus controller ...
... The intent was to provide as much commonality as possible with the Bitbus controller The performance was to be equal or better then the Bitbus chassis Should not cost more then Bitbus controller ...
STK392-110
... • Series of pin compatible power amplifiers ranging from 20 W × 2 channels to 120 W × 2 channels (10%/1 kHz) devices. The same printed circuit board can be used depending on the output power grade. • The pin arrangement is compatible with that of the 3channel STK402-200 series. This means that 3-cha ...
... • Series of pin compatible power amplifiers ranging from 20 W × 2 channels to 120 W × 2 channels (10%/1 kHz) devices. The same printed circuit board can be used depending on the output power grade. • The pin arrangement is compatible with that of the 3channel STK402-200 series. This means that 3-cha ...
LTC2927 - Single Power Supply Tracking
... output of the slave supply. The slave output voltage varies with the master signal, enabling the slave supply to be controlled as a function of the master signal with terms set by RTA and RTB. By selecting appropriate values of RTA and RTB, it is possible to generate any of the profiles in Figures 1 ...
... output of the slave supply. The slave output voltage varies with the master signal, enabling the slave supply to be controlled as a function of the master signal with terms set by RTA and RTB. By selecting appropriate values of RTA and RTB, it is possible to generate any of the profiles in Figures 1 ...
HCAL_cable_issues
... Getting a concept conclusive for all crafts: Need to get basics from all Need in the early stage basic inclusions in the design - Concept for EUDET: Is cable count adequate for scaling to ILD? - Power/GND: Bar-like (thick wires) gets better EMI, less space - Signal: The star-like concept is not the ...
... Getting a concept conclusive for all crafts: Need to get basics from all Need in the early stage basic inclusions in the design - Concept for EUDET: Is cable count adequate for scaling to ILD? - Power/GND: Bar-like (thick wires) gets better EMI, less space - Signal: The star-like concept is not the ...
Quickstart MTC 6 Series ! !
... • Sometimes the position from which the ground signal is to come is specified by the vehicle manufacturer. • Position and connect the MTC 6 as close to the battery as possible. • Do not attach the MTC 6 directly to a connector for a high-powered consumer (e.g. an inverter for fork lift ...
... • Sometimes the position from which the ground signal is to come is specified by the vehicle manufacturer. • Position and connect the MTC 6 as close to the battery as possible. • Do not attach the MTC 6 directly to a connector for a high-powered consumer (e.g. an inverter for fork lift ...
HARDWARE MANUAL
... burst, Electrostatic discharge, High-energy surge, Voltage drops and interruptions, Conducted RF and Power frequency magnetic field) ...
... burst, Electrostatic discharge, High-energy surge, Voltage drops and interruptions, Conducted RF and Power frequency magnetic field) ...
2-GBPS Differential Repeater EVM
... Applying loads outside of the specified output range may result in unintended operation and/or possible permanent damage to the EVM. Please consult the EVM User’s Guide prior to connecting any load to the EVM output. If there is uncertainty as to the load specification, please contact a TI field rep ...
... Applying loads outside of the specified output range may result in unintended operation and/or possible permanent damage to the EVM. Please consult the EVM User’s Guide prior to connecting any load to the EVM output. If there is uncertainty as to the load specification, please contact a TI field rep ...
CNX-P1900 - Carnetix
... advantage to using Sleep Mode is that the Mac will shutdown and resume very quickly (~5 seconds) when controlled by the P1900 SSC (Startup/Shutdown Controller). This is very advantageous in an automotive application. However, using Sleep Mode also means that the P1900 must continue to provide power ...
... advantage to using Sleep Mode is that the Mac will shutdown and resume very quickly (~5 seconds) when controlled by the P1900 SSC (Startup/Shutdown Controller). This is very advantageous in an automotive application. However, using Sleep Mode also means that the P1900 must continue to provide power ...
APC Symmetra RM Installation Manual English
... arrhythmia detectors and alarms, pacemakers, hemodialysis systems, peritoneal dialysis systems, neonatal ventilator incubators, ventilators for both adults and infants, anesthesia ventilators, infusion pumps, and any other device designated as “critical” by the U.S.F.D.A. Hospital grade wiring devic ...
... arrhythmia detectors and alarms, pacemakers, hemodialysis systems, peritoneal dialysis systems, neonatal ventilator incubators, ventilators for both adults and infants, anesthesia ventilators, infusion pumps, and any other device designated as “critical” by the U.S.F.D.A. Hospital grade wiring devic ...
PoE Powered Device for 24 VAC Building Power Applications
... Referring to Figure 1, the 24 VAC auxiliary input circuit is shown to include the following items: • Input fuse F1 for local current fault protection. • MOV VR1 and back-to-back transorbs D1/D3 for input transient protection. • Common-mode choke L1 and filter capacitor C1 for EMI filtering. • Bridge ...
... Referring to Figure 1, the 24 VAC auxiliary input circuit is shown to include the following items: • Input fuse F1 for local current fault protection. • MOV VR1 and back-to-back transorbs D1/D3 for input transient protection. • Common-mode choke L1 and filter capacitor C1 for EMI filtering. • Bridge ...
NX Series Analog Output Units Datasheet
... * OMRON CJ1W-NC@81/@82 Position Control Units cannot be connected to the EtherCAT Slave Terminal even though they support EtherCAT. Sysmac® is a trademark or registered trademark of OMRON Corporation in Japan and other countries for OMRON factory automation products. EtherCAT® is a registered tradem ...
... * OMRON CJ1W-NC@81/@82 Position Control Units cannot be connected to the EtherCAT Slave Terminal even though they support EtherCAT. Sysmac® is a trademark or registered trademark of OMRON Corporation in Japan and other countries for OMRON factory automation products. EtherCAT® is a registered tradem ...
Getting started with STM32F4xxxx MCU hardware development
... Depending on the selected package, there are specific pins that should be connected either to VSS or VDD to activate or deactivate the voltage regulator. Refer to section “Voltage regulator “ in datasheet for details. ...
... Depending on the selected package, there are specific pins that should be connected either to VSS or VDD to activate or deactivate the voltage regulator. Refer to section “Voltage regulator “ in datasheet for details. ...
ZL40200 - Microsemi
... 3.4 Power Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 3.4.1 Sensitivity to power supply noise . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...
... 3.4 Power Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 3.4.1 Sensitivity to power supply noise . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...
83-507-013 - TDK-Lambda Americas Inc.
... in connection with the furnishing, performance or use of this material. No part of this document may be photocopied, reproduced or translated into another language without the prior written consent of TDKLambda Americas Inc. ...
... in connection with the furnishing, performance or use of this material. No part of this document may be photocopied, reproduced or translated into another language without the prior written consent of TDKLambda Americas Inc. ...
PDF
... Electrostatic discharge (ESD) damages equipment and impairs electrical circuitry. ESD occurs when printed circuit boards are improperly handled and results in complete or intermittent failures. The I/O controller, network processing engine, cable modem cards, and port adapters consist of a printed c ...
... Electrostatic discharge (ESD) damages equipment and impairs electrical circuitry. ESD occurs when printed circuit boards are improperly handled and results in complete or intermittent failures. The I/O controller, network processing engine, cable modem cards, and port adapters consist of a printed c ...
Booster Power Supply Manual
... Installation in accordance with this manual, applicable codes, and the instructions of the Authority Having Jurisdiction is mandatory. General Signal Building Systems Corporation shall not under any circumstances be liable for any incidental or consequential damages arising from loss of property or ...
... Installation in accordance with this manual, applicable codes, and the instructions of the Authority Having Jurisdiction is mandatory. General Signal Building Systems Corporation shall not under any circumstances be liable for any incidental or consequential damages arising from loss of property or ...
Control Components
... As shown below, two S8VT-F (same capacity model) can be paralleled to boost the output power (current). Set the output voltages of the Power Supplies to the same value. Also, make sure that the thickness and the length of all wires connected to the load are the same to ensure that the wires will hav ...
... As shown below, two S8VT-F (same capacity model) can be paralleled to boost the output power (current). Set the output voltages of the Power Supplies to the same value. Also, make sure that the thickness and the length of all wires connected to the load are the same to ensure that the wires will hav ...
GENESYS - TDK
... These products are high-power equipment with input power > 1kW for professional use and installation, Class A as defined by EN 55022: 1998+A1:2000+A2:2003 and EN 61000-3.3:1995+A2:2005. Futther, all products covered by this declaration are manufactured in accordance with ISO9001:2001 which ensure co ...
... These products are high-power equipment with input power > 1kW for professional use and installation, Class A as defined by EN 55022: 1998+A1:2000+A2:2003 and EN 61000-3.3:1995+A2:2005. Futther, all products covered by this declaration are manufactured in accordance with ISO9001:2001 which ensure co ...
ElectricalContractors+Final
... type of current reflected into the mains supply. A 12 pulse produces less “harmonic” or non linear current into the mains supply. ...
... type of current reflected into the mains supply. A 12 pulse produces less “harmonic” or non linear current into the mains supply. ...
SKY77762 数据资料DataSheet下载
... The Gallium Arsenide (GaAs) Microwave Monolithic Integrated Circuit (MMIC) contains all amplifier active circuitry, including input and interstage matching circuits. The silicon CMOS support die, providing precision biasing for the MMIC affords a true CMOS-compatible control interface. Output match ...
... The Gallium Arsenide (GaAs) Microwave Monolithic Integrated Circuit (MMIC) contains all amplifier active circuitry, including input and interstage matching circuits. The silicon CMOS support die, providing precision biasing for the MMIC affords a true CMOS-compatible control interface. Output match ...
Uninterruptible Power Supply - Mitsubishi Electric Power Products, Inc.
... The 9800A Series UPS features units with integrated output isolation transformers which can be used to generate a 480Y/271 and 600Y/346 volt 4 wire output. This can be done with Single- or Multi-module applications. ...
... The 9800A Series UPS features units with integrated output isolation transformers which can be used to generate a 480Y/271 and 600Y/346 volt 4 wire output. This can be done with Single- or Multi-module applications. ...
ECOMPACT® 23E/60E
... During operation control and power connections lead dangerous voltages. Never loosen connections if they are live. After disconnecting the device wait at least 3 minutes before touching the contacts. Capacitors can still have dangerous voltages present up to 3 minutes after switching off the supply ...
... During operation control and power connections lead dangerous voltages. Never loosen connections if they are live. After disconnecting the device wait at least 3 minutes before touching the contacts. Capacitors can still have dangerous voltages present up to 3 minutes after switching off the supply ...
IEMD Programming Manual - TDK
... eight control wires and eight ground wires. If the system runs from a personal computer, there are numerous vendors of IEEE controller cards and software. The IEEE-488 standard has gone through several upgrades. The IEEE-488.1 focused on the handshaking of the eight control lines. The IEEE-488.2 add ...
... eight control wires and eight ground wires. If the system runs from a personal computer, there are numerous vendors of IEEE controller cards and software. The IEEE-488 standard has gone through several upgrades. The IEEE-488.1 focused on the handshaking of the eight control lines. The IEEE-488.2 add ...
Power Supply - FormFactors.org
... MERCHANTABILITY, OR INFRINGEMENT OF ANY PATENT, COPYRIGHT OR OTHER INTELLECTUAL PROPERTY RIGHT. Intel products are not intended for use in medical, life saving, or life sustaining applications. Intel may make changes to specifications and product descriptions at any time, without notice. Designers m ...
... MERCHANTABILITY, OR INFRINGEMENT OF ANY PATENT, COPYRIGHT OR OTHER INTELLECTUAL PROPERTY RIGHT. Intel products are not intended for use in medical, life saving, or life sustaining applications. Intel may make changes to specifications and product descriptions at any time, without notice. Designers m ...
Power supply
A power supply is an electronic device that supplies electric energy to an electrical load. The primary function of a power supply is to convert one form of electrical energy to another and, as a result, power supplies are sometimes referred to as electric power converters. Some power supplies are discrete, stand-alone devices, whereas others are built into larger devices along with their loads. Examples of the latter include power supplies found in desktop computers and consumer electronics devices.Every power supply must obtain the energy it supplies to its load, as well as any energy it consumes while performing that task, from an energy source. Depending on its design, a power supply may obtain energy from various types of energy sources, including electrical energy transmission systems, energy storage devices such as a batteries and fuel cells, electromechanical systems such as generators and alternators, solar power converters, or another power supply.All power supplies have a power input, which receives energy from the energy source, and a power output that delivers energy to the load. In most power supplies the power input and output consist of electrical connectors or hardwired circuit connections, though some power supplies employ wireless energy transfer in lieu of galvanic connections for the power input or output. Some power supplies have other types of inputs and outputs as well, for functions such as external monitoring and control.