MNX SERIES High Voltage Power Supply
... The MNX Series is designed to power grounded cathode X-ray tubes from a variety of well known manufacturers. It features a 0 to 50kV high voltage output, and up to 2mA of emission current limited to 50 Watts, operating from a +24Vdc input. The MNX utilizes a closed loop filamentry beam control circu ...
... The MNX Series is designed to power grounded cathode X-ray tubes from a variety of well known manufacturers. It features a 0 to 50kV high voltage output, and up to 2mA of emission current limited to 50 Watts, operating from a +24Vdc input. The MNX utilizes a closed loop filamentry beam control circu ...
Comparison of the AC UPS and the DC UPS solutions for critical loads
... Soon it was found that alternating current, ac, had some important advantages – ease of changing the voltage level by means of transformers, less wear and tear of switches (caused by arcing) and so on. Electric light bulbs worked fine on ac and so did electrical machines, at least as long you had no ...
... Soon it was found that alternating current, ac, had some important advantages – ease of changing the voltage level by means of transformers, less wear and tear of switches (caused by arcing) and so on. Electric light bulbs worked fine on ac and so did electrical machines, at least as long you had no ...
Chapter 4
... d. Note that the flow of electricity throughout the complete, closed circuit is driven by the difference in potential between source and sink located at the power station. 2. Describe short circuits and the role of fuses in protecting devices from excess current flow. 3. Discuss how grounds are used ...
... d. Note that the flow of electricity throughout the complete, closed circuit is driven by the difference in potential between source and sink located at the power station. 2. Describe short circuits and the role of fuses in protecting devices from excess current flow. 3. Discuss how grounds are used ...
Triple II Demand Instruments
... occasionally experienced in the field. The MOV's are designed to clamp applied power voltages above 170V ac RMS (270 V ac RMS for 230V instruments). To avoid damaging the MOV protectors, maintain continuously applied power voltages within the ratings of the instrument. 2.3 Interconnect and Power Sup ...
... occasionally experienced in the field. The MOV's are designed to clamp applied power voltages above 170V ac RMS (270 V ac RMS for 230V instruments). To avoid damaging the MOV protectors, maintain continuously applied power voltages within the ratings of the instrument. 2.3 Interconnect and Power Sup ...
CD20_Technical-Information_en-US_RevA
... power leads to meet the conducted emission requirements for the industrial environment. This filtering blocks conducted-type emissions from exiting onto the power lines and provides a barrier for EMI on the power lines. Be sure to adequately size the system. The type of filter is based on the voltag ...
... power leads to meet the conducted emission requirements for the industrial environment. This filtering blocks conducted-type emissions from exiting onto the power lines and provides a barrier for EMI on the power lines. Be sure to adequately size the system. The type of filter is based on the voltag ...
High Voltage Power
... of medical, industrial, military, research and semiconductor applications worldwide. Pulsed Lasers - ALE series high voltage capacitor charging and DC supplies can be used in almost all types of pulsed laser. For excimer lasers requiring very high pulse to pulse stability, our patented parallel reso ...
... of medical, industrial, military, research and semiconductor applications worldwide. Pulsed Lasers - ALE series high voltage capacitor charging and DC supplies can be used in almost all types of pulsed laser. For excimer lasers requiring very high pulse to pulse stability, our patented parallel reso ...
XAPP946 - 适用于 Virtex-4 RocketIO MGT 的开关电源
... generators, and amplifiers, noise on the power supply can couple into critical parts of the circuit and degrade jitter tolerance or output jitter. The most absolute method of avoiding this issue is to use relatively quiet power supplies such as linear regulators. Easy to implement and low in cost, l ...
... generators, and amplifiers, noise on the power supply can couple into critical parts of the circuit and degrade jitter tolerance or output jitter. The most absolute method of avoiding this issue is to use relatively quiet power supplies such as linear regulators. Easy to implement and low in cost, l ...
a Engineer To Engineer Note EE-169
... This will ensure that the power supply design will provide sufficient voltage at a relatively high efficiency (typically greater than 90%) to each of the two voltage domains (VDD and VDD_IO) during sustained periods of maximum activity. This is due to the fact that the power required during a sustai ...
... This will ensure that the power supply design will provide sufficient voltage at a relatively high efficiency (typically greater than 90%) to each of the two voltage domains (VDD and VDD_IO) during sustained periods of maximum activity. This is due to the fact that the power required during a sustai ...
Load power supply module PM 70 W 120/230VAC (6EP1332
... task in accordance with the relevant documentation, in particular its warning notices and safety instructions. Qualified personnel are those who, based on their training and experience, are capable of identifying risks and avoiding potential hazards when working with these products/systems. ...
... task in accordance with the relevant documentation, in particular its warning notices and safety instructions. Qualified personnel are those who, based on their training and experience, are capable of identifying risks and avoiding potential hazards when working with these products/systems. ...
H3DEZ 22.5 mm Timer
... The H3DEZ Series is provided with a transformerless power supply system. An electric shock may be received if the output type selector switch is touched while power is being supplied. Use the bar terminal for wiring the H3DEZ. Using a stranded-wire terminal may cause a short-circuit due to a stray w ...
... The H3DEZ Series is provided with a transformerless power supply system. An electric shock may be received if the output type selector switch is touched while power is being supplied. Use the bar terminal for wiring the H3DEZ. Using a stranded-wire terminal may cause a short-circuit due to a stray w ...
Simplifying the transition to digital power for
... For a simple, inexpensive power supply where efficiency doesn’t matter and there is no need for advanced features, analog-based systems cannot be beat. However, for applications where efficiency, responsiveness, accuracy, and other additional system functions such as input power monitoring are impor ...
... For a simple, inexpensive power supply where efficiency doesn’t matter and there is no need for advanced features, analog-based systems cannot be beat. However, for applications where efficiency, responsiveness, accuracy, and other additional system functions such as input power monitoring are impor ...
Installation and Operations Manual PoweRack 230e Power Unit
... The rectifier/Charger used in the PoweRack230e is a constant voltage/current limited device, which allows it to be safely used for battery charging as well as providing power to the load. What this means is, that if the load being drawn from the unit is minimal, then the output voltage will be const ...
... The rectifier/Charger used in the PoweRack230e is a constant voltage/current limited device, which allows it to be safely used for battery charging as well as providing power to the load. What this means is, that if the load being drawn from the unit is minimal, then the output voltage will be const ...
power quality guidebook
... performance, improve efficiencies, preserve data and increase equipment longevity. Our comprehensive line of products stretch from entrances to load points to communications networks throughout facilities, making our total power quality solutions indispensable to today’s industries. Total power qual ...
... performance, improve efficiencies, preserve data and increase equipment longevity. Our comprehensive line of products stretch from entrances to load points to communications networks throughout facilities, making our total power quality solutions indispensable to today’s industries. Total power qual ...
Development of a microcontroller-based, photovoltaic maximum
... a microcontroller, but the design described above has the advantage that it permits easy modification, if additional renewable energy sources (e.g., more PV arrays or wind generators) are used. Also, in case that the system is used in a solar-powered vehicle, the microcontroller MPPT algorithm can b ...
... a microcontroller, but the design described above has the advantage that it permits easy modification, if additional renewable energy sources (e.g., more PV arrays or wind generators) are used. Also, in case that the system is used in a solar-powered vehicle, the microcontroller MPPT algorithm can b ...
AN-916 A Multifunction Power Meter Reference Design Based on
... different operating conditions. To produce an efficient metering system with low power consumption and extended battery life, it is important to carefully choose the power supply that is connected to the external circuitry. Following are the three main power supplies to choose from when connecting e ...
... different operating conditions. To produce an efficient metering system with low power consumption and extended battery life, it is important to carefully choose the power supply that is connected to the external circuitry. Following are the three main power supplies to choose from when connecting e ...
RM450 Rack Kit - Aim-TTi
... being used towards the higher end of their current range (Note 1), this will not be sufficient. Generally, to ensure adequate air-flow for PL supplies, an additional ventilated 1U spacer should be placed both above and below the RM450A. Where the RM450A is being placed at the bottom of a rack, venti ...
... being used towards the higher end of their current range (Note 1), this will not be sufficient. Generally, to ensure adequate air-flow for PL supplies, an additional ventilated 1U spacer should be placed both above and below the RM450A. Where the RM450A is being placed at the bottom of a rack, venti ...
MAX9989/MAX9990 +14dBm to +20dBm LO Buffers with ±1dB Variation General Description
... from the average of 30 units from a typical lot, and are tested under the conditions specified for the typical specifications. Note 2: DC current limits at -40°C are guaranteed by design and characterization. ...
... from the average of 30 units from a typical lot, and are tested under the conditions specified for the typical specifications. Note 2: DC current limits at -40°C are guaranteed by design and characterization. ...
VSC8476
... function, 16:1 mux/demux and high speed I/O. The VSC8476 also offers an additional data output with programmable preemphasis to enable longer links for copper. With these functions the VSC8476 implements the IEEE 802.3ae and T11 10GFC XGMII Extender Sub-layer (XGXS), Physical Coding Sub layer (PCS), ...
... function, 16:1 mux/demux and high speed I/O. The VSC8476 also offers an additional data output with programmable preemphasis to enable longer links for copper. With these functions the VSC8476 implements the IEEE 802.3ae and T11 10GFC XGMII Extender Sub-layer (XGXS), Physical Coding Sub layer (PCS), ...
Anatomy of Switching Power Supplies
... check whether your power supply is a good one or not is by checking if its transient filtering stage has all recommended components or not. Its main component is called MOV (Metal Oxide Varistor) or varistor, labeled RV1 on our schematics, which is responsible for cutting voltage spikes (transients ...
... check whether your power supply is a good one or not is by checking if its transient filtering stage has all recommended components or not. Its main component is called MOV (Metal Oxide Varistor) or varistor, labeled RV1 on our schematics, which is responsible for cutting voltage spikes (transients ...
Conquering the Multi Kilowatt Source/Sink Test
... sourced from the DUT. This way the electronic load always remains in CC mode, drawing a ixed level of current and power. The electronic load no longer has to contend with any mode cross-over issues. The DC source always remains in CV mode and is always sourcing current. Because of this, the blocking ...
... sourced from the DUT. This way the electronic load always remains in CC mode, drawing a ixed level of current and power. The electronic load no longer has to contend with any mode cross-over issues. The DC source always remains in CV mode and is always sourcing current. Because of this, the blocking ...
DS1812 5V EconoReset with Active High Push-Pull Output FEATURES
... The DS1812 EconoReset uses a precision temperature reference and comparator circuit to monitor the status of the power supply (VCC). When an out-of-tolerance condition is detected, an internal power-fail signal is generated which forces reset to the active state. When VCC returns to an in-tolerance ...
... The DS1812 EconoReset uses a precision temperature reference and comparator circuit to monitor the status of the power supply (VCC). When an out-of-tolerance condition is detected, an internal power-fail signal is generated which forces reset to the active state. When VCC returns to an in-tolerance ...
PFC FrontEndTM Power Factor Corrected AC-DC FrontEnd
... comes up properly. After that, control of this function is handed over to the input lines E/D 1-4. Please note that any external load, whether a Vicor module or other, must be disabled during the startup phase. Individual outputs may be connected to more than one module to form output arrays. Each c ...
... comes up properly. After that, control of this function is handed over to the input lines E/D 1-4. Please note that any external load, whether a Vicor module or other, must be disabled during the startup phase. Individual outputs may be connected to more than one module to form output arrays. Each c ...
The Seven Types Of Power Problems
... of an oscillatory transient occurs. For example, upon turning off a spinning motor, it acts briefly as a generator as it powers down, thereby producing electricity and sending it through the electrical distribution. A long electrical distribution system can act like an oscillator when power is switc ...
... of an oscillatory transient occurs. For example, upon turning off a spinning motor, it acts briefly as a generator as it powers down, thereby producing electricity and sending it through the electrical distribution. A long electrical distribution system can act like an oscillator when power is switc ...
PRATHAM: A Power Delivery-Aware and Thermal-Aware Mapping Framework for Parallel
... Power-performance model: The impact of PDN IR-drops and chip thermal profile on performance and power dissipation is captured by the power-performance model. In each iteration of execution, updated values of core-temperatures (t’s) and supply voltages (V’s) are first utilized to update the core-freq ...
... Power-performance model: The impact of PDN IR-drops and chip thermal profile on performance and power dissipation is captured by the power-performance model. In each iteration of execution, updated values of core-temperatures (t’s) and supply voltages (V’s) are first utilized to update the core-freq ...
OX2324872492
... Therefore, an ultra-low power comparator was designed which is not only supportive to ultra-low power operation but also has higher resolution. So we have first designed the schematic of two stage opamp based open loop comparator on TANNER V7 EDA TOOL .After that we simulated the design and analysed ...
... Therefore, an ultra-low power comparator was designed which is not only supportive to ultra-low power operation but also has higher resolution. So we have first designed the schematic of two stage opamp based open loop comparator on TANNER V7 EDA TOOL .After that we simulated the design and analysed ...
Power supply
A power supply is an electronic device that supplies electric energy to an electrical load. The primary function of a power supply is to convert one form of electrical energy to another and, as a result, power supplies are sometimes referred to as electric power converters. Some power supplies are discrete, stand-alone devices, whereas others are built into larger devices along with their loads. Examples of the latter include power supplies found in desktop computers and consumer electronics devices.Every power supply must obtain the energy it supplies to its load, as well as any energy it consumes while performing that task, from an energy source. Depending on its design, a power supply may obtain energy from various types of energy sources, including electrical energy transmission systems, energy storage devices such as a batteries and fuel cells, electromechanical systems such as generators and alternators, solar power converters, or another power supply.All power supplies have a power input, which receives energy from the energy source, and a power output that delivers energy to the load. In most power supplies the power input and output consist of electrical connectors or hardwired circuit connections, though some power supplies employ wireless energy transfer in lieu of galvanic connections for the power input or output. Some power supplies have other types of inputs and outputs as well, for functions such as external monitoring and control.