REF01,02,03 - Analog Devices
... With an external buffer and a simple resistor network, the TEMP terminal can be used for temperature sensing and approximation. A TRIM terminal is also provided on the device for fine adjustment of the output voltage. The small footprint, wide supply range, and application versatility make the REF01 ...
... With an external buffer and a simple resistor network, the TEMP terminal can be used for temperature sensing and approximation. A TRIM terminal is also provided on the device for fine adjustment of the output voltage. The small footprint, wide supply range, and application versatility make the REF01 ...
TPS62750 数据资料 dataSheet 下载
... synchronous step down dc-dc converter optimized for USB powered portable applications. It can provide up to 1300mA average input current and is ideal for applications connected to a USB host. With an input voltage range of 2.9 V to 6.0V, the device supports batteries with extended voltage range and ...
... synchronous step down dc-dc converter optimized for USB powered portable applications. It can provide up to 1300mA average input current and is ideal for applications connected to a USB host. With an input voltage range of 2.9 V to 6.0V, the device supports batteries with extended voltage range and ...
9- Control Strategy for Three-Phase PWM Boost Rectifier Operating
... performance of the rectifier under harmonic conditions of the networks, the method has several advantages: simple, it uses constant switching frequency, and excellent step response. Alsothis method has some disadvantages: the unbalanced condition at the input voltages is not discussed, only balanced ...
... performance of the rectifier under harmonic conditions of the networks, the method has several advantages: simple, it uses constant switching frequency, and excellent step response. Alsothis method has some disadvantages: the unbalanced condition at the input voltages is not discussed, only balanced ...
BJT Small-Signal Analysis Steps
... For example, if the emitter terminal is connected to ground, and one terminal of a resistor is connected to ground, then that resistor terminal is connected to the emitter! * As a result, you often find that resistors in different parts of the circuit are actually connected in parallel, and thus can ...
... For example, if the emitter terminal is connected to ground, and one terminal of a resistor is connected to ground, then that resistor terminal is connected to the emitter! * As a result, you often find that resistors in different parts of the circuit are actually connected in parallel, and thus can ...
Final Report - University of Portland
... An electronic ballast is an apparatus that controls the current flow into a circuit. In this case, the circuit is a fluorescent lamp. There are various types of ballasts, but the electronic ballast increases the input frequency (typically 60 Hz in the United States) to a much higher frequency in the ...
... An electronic ballast is an apparatus that controls the current flow into a circuit. In this case, the circuit is a fluorescent lamp. There are various types of ballasts, but the electronic ballast increases the input frequency (typically 60 Hz in the United States) to a much higher frequency in the ...
LMV321/358/324 Single/Dual/Quad Gen Purpose, Low V, R-to
... The LMV358-N and LMV324-N are low-voltage (2.7 V to 5.5 V) versions of the dual and quad commodity op amps LM358 and LM324 (5 V to 30 V). The LMV321N is the single channel version. The LMV321-N, LMV358-N, and LMV324-N are the most costeffective solutions for applications where low-voltage operation, ...
... The LMV358-N and LMV324-N are low-voltage (2.7 V to 5.5 V) versions of the dual and quad commodity op amps LM358 and LM324 (5 V to 30 V). The LMV321N is the single channel version. The LMV321-N, LMV358-N, and LMV324-N are the most costeffective solutions for applications where low-voltage operation, ...
MAX110/MAX111 Low-Cost, 2-Channel, ±14-Bit Serial ADCs General Description ____________________________Features
... Note 1: These specifications apply after auto-null and gain calibration. Performance at power-supply tolerance limits is guaranteed by power-supply rejection tests. Tests are performed at VDD = 5V and VSS = -5V (MAX110). Note 2: 32,768 LSBs cover an input voltage range of ±VREF (15 bits). An additio ...
... Note 1: These specifications apply after auto-null and gain calibration. Performance at power-supply tolerance limits is guaranteed by power-supply rejection tests. Tests are performed at VDD = 5V and VSS = -5V (MAX110). Note 2: 32,768 LSBs cover an input voltage range of ±VREF (15 bits). An additio ...
Steps for Small Sign..
... Many things will be connected to ground! Once the DC voltage sources are turned off, you will find that the terminals of many devices are connected to ground. * Remember, all terminals connected to ground are also connected to each other! For example, if the emitter terminal is connected to ground, ...
... Many things will be connected to ground! Once the DC voltage sources are turned off, you will find that the terminals of many devices are connected to ground. * Remember, all terminals connected to ground are also connected to each other! For example, if the emitter terminal is connected to ground, ...
$doc.title
... Instruments has added an estimate of not only the typical values, but also the spread around these values. These are in the form of distribution bars that show the 95% (upper) points and the 5% (lower) points from the characterization of the initial wafer lots of this new device type (see Figure 5). ...
... Instruments has added an estimate of not only the typical values, but also the spread around these values. These are in the form of distribution bars that show the 95% (upper) points and the 5% (lower) points from the characterization of the initial wafer lots of this new device type (see Figure 5). ...
Low Input Voltage, 0.7V, Boost Converter With 5.5μA Quiescent
... solution for products powered by either a single-cell, two-cell, or three-cell alkaline, NiCd or NiMH, or onecell Li-Ion or Li-polymer battery. Possible output currents depend on the input-to-output voltage ratio. The boost converter is based on a hysteretic controller topology using synchronous rec ...
... solution for products powered by either a single-cell, two-cell, or three-cell alkaline, NiCd or NiMH, or onecell Li-Ion or Li-polymer battery. Possible output currents depend on the input-to-output voltage ratio. The boost converter is based on a hysteretic controller topology using synchronous rec ...
FPF2140/42/43/44/46/47 Full Function Load Switch with Reverse Current Blocking Features
... The current limit guarantees that the current through the switch doesn't exceed a maximum value while not limiting at less than a minimum value. For the FPF2140/42/43 the minimum current is 200mA and the maximum current is 400mA and for the FPF2144/46/47 the minimum current is 400mA and the maximum ...
... The current limit guarantees that the current through the switch doesn't exceed a maximum value while not limiting at less than a minimum value. For the FPF2140/42/43 the minimum current is 200mA and the maximum current is 400mA and for the FPF2144/46/47 the minimum current is 400mA and the maximum ...
Handbook on Electricity Meters
... The measurement of electricity is a complex process. Achieving accuracy and equity in the trade of electricity requires an effective system for achieving metrological control, and a consistent application of the measured quantities. ...
... The measurement of electricity is a complex process. Achieving accuracy and equity in the trade of electricity requires an effective system for achieving metrological control, and a consistent application of the measured quantities. ...
Multimeter
A multimeter or a multitester, also known as a VOM (Volt-Ohm meter or Volt-Ohm-milliammeter ), is an electronic measuring instrument that combines several measurement functions in one unit. A typical multimeter would include basic features such as the ability to measure voltage, current, and resistance. Analog multimeters use a microammeter whose pointer moves over a scale calibrated for all the different measurements that can be made. Digital multimeters (DMM, DVOM) display the measured value in numerals, and may also display a bar of a length proportional to the quantity being measured. Digital multimeters are now far more common but analog multimeters are still preferable in some cases, for example when monitoring a rapidly varying value. A multimeter can be a hand-held device useful for basic fault finding and field service work, or a bench instrument which can measure to a very high degree of accuracy. They can be used to troubleshoot electrical problems in a wide array of industrial and household devices such as electronic equipment, motor controls, domestic appliances, power supplies, and wiring systems.Multimeters are available in a wide range of features and prices. Cheap multimeters can cost less than US$10, while laboratory-grade models with certified calibration can cost more than US$5,000.