
Components in Sensing Circuits Word Document
... Unit E1 : Discovering Electronics Potentiometers can also be set up to act as variable resistors in circuits. In this case the wiper tag is connected to one of the end of track tags and the unit is used as shown opposite. ...
... Unit E1 : Discovering Electronics Potentiometers can also be set up to act as variable resistors in circuits. In this case the wiper tag is connected to one of the end of track tags and the unit is used as shown opposite. ...
lecture 070 – resistors and inductors
... Multi-Level Spiral Inductors Use of more than one level of metal to make the inductor. • Can get more inductance per area • Can increase the interwire capacitance so the different levels are often offset to get minimum overlap. • Multi-level spiral inductors suffer from contact resistance (must have ...
... Multi-Level Spiral Inductors Use of more than one level of metal to make the inductor. • Can get more inductance per area • Can increase the interwire capacitance so the different levels are often offset to get minimum overlap. • Multi-level spiral inductors suffer from contact resistance (must have ...
11.3 Gbps, Active Back-Termination, Differential VCSEL Driver ADN2530
... the driver (see Figure 23). The ac-coupling capacitors should have an impedance less than 50 Ω over the required frequency range. Generally, this is achieved using 10 nF to 100 nF capacitors. ...
... the driver (see Figure 23). The ac-coupling capacitors should have an impedance less than 50 Ω over the required frequency range. Generally, this is achieved using 10 nF to 100 nF capacitors. ...
MAX1760/MAX1760H 0.8A, Low-Noise, 1MHz, Step-Up DC-DC Converter General Description
... voltage input to a fixed 3.3V or adjustable voltage between 2.5V and 5.5V. An external Schottky diode is required for output voltages greater than 4V. The MAX1760 guarantees startup with an input voltage as low as 1.1V and remains operational down to an input of just 0.7V. It is optimized for use in ...
... voltage input to a fixed 3.3V or adjustable voltage between 2.5V and 5.5V. An external Schottky diode is required for output voltages greater than 4V. The MAX1760 guarantees startup with an input voltage as low as 1.1V and remains operational down to an input of just 0.7V. It is optimized for use in ...
Switching Applications of a Diode
... 2. Set the function generator to produce a square-wave output, 10 V peak to peak amplitude, centered on 0 V. 3. Start with a 5 kHz square wave. Since we are interested in the current through the circuit, observe the voltage across the resistor with the oscilloscope. (The current is then the voltage ...
... 2. Set the function generator to produce a square-wave output, 10 V peak to peak amplitude, centered on 0 V. 3. Start with a 5 kHz square wave. Since we are interested in the current through the circuit, observe the voltage across the resistor with the oscilloscope. (The current is then the voltage ...
Product manual for the 4-Quadrant-/ Combi meter
... The contents of this manual are protected by copyright. It is forbidden to translate, reprint, copy or store the contents in electronic data processing systems without the express permission of the EMH. All trade marks and product names mentioned in this manual are the property of the EMH metering ...
... The contents of this manual are protected by copyright. It is forbidden to translate, reprint, copy or store the contents in electronic data processing systems without the express permission of the EMH. All trade marks and product names mentioned in this manual are the property of the EMH metering ...
Lithium Ion Charge Management IC with Integrated Switching
... Battery Insertion and Removal VBAT is interpreted by the bq2954 to detect the presence or absence of a battery. The bq2954 determines that a battery is present when VBAT is between the High-Voltage Cutoff (V HCO = V REG + 0.25V) and the Low-Voltage Cutoff (VLCO = 0.8V). When VBAT is outside this ran ...
... Battery Insertion and Removal VBAT is interpreted by the bq2954 to detect the presence or absence of a battery. The bq2954 determines that a battery is present when VBAT is between the High-Voltage Cutoff (V HCO = V REG + 0.25V) and the Low-Voltage Cutoff (VLCO = 0.8V). When VBAT is outside this ran ...
Release 1.0 – September 2006
... might want to run in our vehicles. The typical automobile battery usually supplies about 12 volts. Release 1.0 – September 2006 ...
... might want to run in our vehicles. The typical automobile battery usually supplies about 12 volts. Release 1.0 – September 2006 ...
Manufacturer Specifications – What do they Mean
... performance specifications were developed from tests conducted under a particular set of conditions. If so, additional specifications, such as thermal zero shift, thermal sensitivity shift and thermal transient response error, are included to account for the variation in actual MTE operating conditi ...
... performance specifications were developed from tests conducted under a particular set of conditions. If so, additional specifications, such as thermal zero shift, thermal sensitivity shift and thermal transient response error, are included to account for the variation in actual MTE operating conditi ...
MAX1190 Dual 10-Bit, 120Msps, 3.3V, Low-Power ADC General Description
... The MAX1190 is a 3.3V, dual 10-bit analog-to-digital converter (ADC) featuring fully differential wideband trackand-hold (T/H) inputs, driving two ADCs. The MAX1190 is optimized for low power, small size, and high-dynamic performance for applications in imaging, instrumentation, and digital communic ...
... The MAX1190 is a 3.3V, dual 10-bit analog-to-digital converter (ADC) featuring fully differential wideband trackand-hold (T/H) inputs, driving two ADCs. The MAX1190 is optimized for low power, small size, and high-dynamic performance for applications in imaging, instrumentation, and digital communic ...
BD9862MUV
... because the inductance varies in value. 3) Setting of output capacitor The capacitance & ESR of the output capacitor is influenced a great deal by output voltage ripple. Moreover, PFM mode intentionally makes the switching intermittent, so the output voltage ripple becomes larger compared with PWM m ...
... because the inductance varies in value. 3) Setting of output capacitor The capacitance & ESR of the output capacitor is influenced a great deal by output voltage ripple. Moreover, PFM mode intentionally makes the switching intermittent, so the output voltage ripple becomes larger compared with PWM m ...
Circuit Analysis I
... Each chapter contains numerous practical applications supplemented with detailed instructions for using MATLAB to obtain quick and accurate answers. ...
... Each chapter contains numerous practical applications supplemented with detailed instructions for using MATLAB to obtain quick and accurate answers. ...
Wideband, Low-Power, Current Feedback Operational Amplifier OPA694 FEATURES
... gain of +2, along with a 1700V/ms slew rate. An improved output stage provides ±80mA output drive, along with < 1.5V output voltage headroom. This combination of low power and high bandwidth can benefit high-resolution video applications. Figure 31 shows the DC-coupled, gain of +2, dual power-supply ...
... gain of +2, along with a 1700V/ms slew rate. An improved output stage provides ±80mA output drive, along with < 1.5V output voltage headroom. This combination of low power and high bandwidth can benefit high-resolution video applications. Figure 31 shows the DC-coupled, gain of +2, dual power-supply ...
ppt
... check for CONTINUITY – This means checking that electricity flows all the way through the circuit. – If it is disrupted somehow- there will be no continuity. ...
... check for CONTINUITY – This means checking that electricity flows all the way through the circuit. – If it is disrupted somehow- there will be no continuity. ...
Basics of Meter Mounting Equipment
... of single-position and multiple-position meter sockets. Single-position meter sockets are used for single-family homes and in some commercial applications. Multiple-position meter sockets, also called gang sockets, are used in multifamily and other commercial applications requiring two to six meters ...
... of single-position and multiple-position meter sockets. Single-position meter sockets are used for single-family homes and in some commercial applications. Multiple-position meter sockets, also called gang sockets, are used in multifamily and other commercial applications requiring two to six meters ...
Per-Unit - Iowa State University
... Normally, in power systems, power bases are specified as kVA or MVA. One must always ensure these values are converted to units of VA before using the above formula (1 kVA=1x10 3 VA, 1 MVA=1x106 VA). Likewise, voltage bases are usually specified as kV. One must always ensure these values are convert ...
... Normally, in power systems, power bases are specified as kVA or MVA. One must always ensure these values are converted to units of VA before using the above formula (1 kVA=1x10 3 VA, 1 MVA=1x106 VA). Likewise, voltage bases are usually specified as kV. One must always ensure these values are convert ...
Multimeter
A multimeter or a multitester, also known as a VOM (Volt-Ohm meter or Volt-Ohm-milliammeter ), is an electronic measuring instrument that combines several measurement functions in one unit. A typical multimeter would include basic features such as the ability to measure voltage, current, and resistance. Analog multimeters use a microammeter whose pointer moves over a scale calibrated for all the different measurements that can be made. Digital multimeters (DMM, DVOM) display the measured value in numerals, and may also display a bar of a length proportional to the quantity being measured. Digital multimeters are now far more common but analog multimeters are still preferable in some cases, for example when monitoring a rapidly varying value. A multimeter can be a hand-held device useful for basic fault finding and field service work, or a bench instrument which can measure to a very high degree of accuracy. They can be used to troubleshoot electrical problems in a wide array of industrial and household devices such as electronic equipment, motor controls, domestic appliances, power supplies, and wiring systems.Multimeters are available in a wide range of features and prices. Cheap multimeters can cost less than US$10, while laboratory-grade models with certified calibration can cost more than US$5,000.