• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
LF155/LF156/LF157 Series Monolithic JFET Input Operational Amplifiers LF155/LF156/LF157 General Description
LF155/LF156/LF157 Series Monolithic JFET Input Operational Amplifiers LF155/LF156/LF157 General Description

... of the input voltages should be allowed to exceed the negative supply as this will cause large currents to flow which can result in a destroyed unit. Exceeding the negative common-mode limit on either input will force the output to a high state, potentially causing a reversal of phase to the output. ...
d - UniMAP Portal
d - UniMAP Portal

RD-3x Dytronic Energy Reference Standard
RD-3x Dytronic Energy Reference Standard

... consisting of a Radian designed Integrating Analog to Digital Signal Converter. Unlike off-the-shelf A/D converters used in similar instruments, Radian’s A/D Converter is specifically designed and optimized for power and energy measurement. This unique design makes the RD-3x absolutely unsurpassed i ...
MODEL6010A Instruction Manual
MODEL6010A Instruction Manual

... 1.This instrument must only be used by a competent and trained person and operated in strict accordance with the instructions. KYORITSU will not accept liability for any damage or injury caused by misuse or noncompliance with the instructions or with the safety procedures. 2.It is essential to rea ...
Paper 2 - DJT Electrical Training
Paper 2 - DJT Electrical Training

... 15 o/c 4 – table 41.1 What will be the operating time for a 60A BS 3036 protective device when the value of fault current is 205A: a 0.2 seconds. b 0.4 seconds. c 0.8 seconds. d 5.0 seconds. 16 o/c 4 - The current rating of a BS 3036 fuse should not exceed that of the lowest rated conductor in the c ...
Supply Voltage and Temperature Insensitive Current Reference for
Supply Voltage and Temperature Insensitive Current Reference for

MAX328/MAX329 Ultra-Low Leakage Monolithic CMOS Analog Multiplexers General Description
MAX328/MAX329 Ultra-Low Leakage Monolithic CMOS Analog Multiplexers General Description

... The resistors, R, need to be 39kΩ or higher to limit the power dissipation in the resistor when a 120V AC fault occurs (i.e., power dissipation is (120-16) 2/39kΩ or 0.28W. This is why a 1/2/W resistor is needed). The circuit withstands an indefinite fault to a 120V AC line with no damage to any com ...
introduction to engineering lab ii (ece 1201) - electronics
introduction to engineering lab ii (ece 1201) - electronics

... Dress Codes and Ethics ............................................................................................................ - 3 Safety ....................................................................................................................................... - 4 Acquaint yourself ...
Resistors Value Lesson Plan
Resistors Value Lesson Plan

... A resistor is small but important component of your project. The components on your circuit board need to be protected, if we fed a 12 volt current from a battery directly to your small components they would be damaged. A resistor placed in front of a component will only allow a certain current to p ...
DAC 1 - godinweb
DAC 1 - godinweb

The Differential Amplifier BJT Differential Pair
The Differential Amplifier BJT Differential Pair

... Differential pair circuits are one of the most widely used circuit building blocks. The input stage of every op amp is a differential amplifier Basic Characteristics – Two matched transistors with emitters shorted together and connected to a current source – Devices must always be in active mode – A ...
FC350™ Fuel Cell Monitor
FC350™ Fuel Cell Monitor

LED
LED

... Example: Source Voltage = 9 volts Voltage Drop = 3.1 volts typical for a blue or white LED Desired Current = 13 milliamps So the resistor we need is: (9 – 3.1) / ( 13 / 1000 ) = 452 ohms so we will use a 470 Ω resistor. ...
Playmaster No. 11 amplifier
Playmaster No. 11 amplifier

INA114 数据资料 dataSheet 下载
INA114 数据资料 dataSheet 下载

... normal. For example, an input voltage of +20V on one input and +40V on the other input will obviously exceed the linear common-mode range of both input amplifiers. Since both input amplifiers are saturated to nearly the same output voltage limit, the difference voltage measured by the output amplifi ...
David Walter - אתר מורי הפיזיקה
David Walter - אתר מורי הפיזיקה

... ‫אתר בית הספר בו מלמד המורה)‪ ,‬העמדה לרשות הציבור או הפצה בדרך אחרת כלשהי של‬ ‫‪.‬קובץ זה או כל חלק ממנו‬ ...
Fast digital calibration procedure for STPM01 based energy meters
Fast digital calibration procedure for STPM01 based energy meters

... According to what pointed out above, it is possible to calibrate STPM01 based energy meters by calibration of voltage and current channels rather than of output pulse signal frequency. Since any energy measure performed by the device (active wide band and active fundamental, reactive or apparent) is ...
Appendix A Specifications and Quick Starts
Appendix A Specifications and Quick Starts

... The Quick Starts in the following sections were designed to provide a quick introduction to the instrument. It was intended that some of them would be covered in labs or tutorials. For maximum effectiveness you are strongly urged to work your way through them before beginning a lab where the instrum ...
MegaPulse 1.2x50 8x20-12P 12ohm rev 1.0
MegaPulse 1.2x50 8x20-12P 12ohm rev 1.0

... The high voltage circuit of the MegaPulse 1.2x50/8x20-12P 12 ohm can be shut off at any time by turning OFF the rear power switch. Always press TRIGGER to discharge the tester before turning OFF. The MegaPulse tester is provided with a VOLTAGE ADJUST knob on the front panel. This should always be ad ...
5MS/s Power Analyzer
5MS/s Power Analyzer

... PZ4000 are calculated based on voltage, current, and active power. (However, reactive power is measured directly during harmonic measurement.) Therefore, during distorted wave input, there may be a difference between these values and those of other measuring instruments based on different measuremen ...
Metering Procedures for LREC/ZREC Projects
Metering Procedures for LREC/ZREC Projects

... configuration – the top or line side “jaws” should be wired to the generator and the bottom or load side jaws should be wired to the customers load. Instrument Transformer Rated Metering For instrument transformer rated metering, the CT polarity marks should be facing away from the generator, pointi ...
Conversion of voltmeter to ammeter and vice-versa
Conversion of voltmeter to ammeter and vice-versa

... 7. Begin converting an ammeter to a voltmeter by determining the resistance Rm of the ammeter. Make the circuit connections as shown in Fig 3(a). The resistance R in series with the ammeter must be kept at large value to prevent large current from flowing through the ammeter and damaging it. 8. Cha ...
_______________General Description ____________________________Features
_______________General Description ____________________________Features

... and V- present. As with Figures 8 and 9, either an Nchannel or a P-channel device will be off for any input voltage from -40V to +40V. The leakage current with negative overvoltages will immediately drop to a few nanoamps at +25°C. For positive overvoltages, that fault current will initially be 10µA ...
AN-127 LM143 Monolithic High Voltage Operational Amplifier
AN-127 LM143 Monolithic High Voltage Operational Amplifier

BAW156...
BAW156...

... The information given in this dokument shall in no event be regarded as a guarantee of conditions or characteristics (“Beschaffenheitsgarantie”). With respect to any examples or hints given herein, any typical values stated herein and/or any information regarding the application of the device, Infin ...
< 1 ... 203 204 205 206 207 208 209 210 211 ... 654 >

Multimeter



A multimeter or a multitester, also known as a VOM (Volt-Ohm meter or Volt-Ohm-milliammeter ), is an electronic measuring instrument that combines several measurement functions in one unit. A typical multimeter would include basic features such as the ability to measure voltage, current, and resistance. Analog multimeters use a microammeter whose pointer moves over a scale calibrated for all the different measurements that can be made. Digital multimeters (DMM, DVOM) display the measured value in numerals, and may also display a bar of a length proportional to the quantity being measured. Digital multimeters are now far more common but analog multimeters are still preferable in some cases, for example when monitoring a rapidly varying value. A multimeter can be a hand-held device useful for basic fault finding and field service work, or a bench instrument which can measure to a very high degree of accuracy. They can be used to troubleshoot electrical problems in a wide array of industrial and household devices such as electronic equipment, motor controls, domestic appliances, power supplies, and wiring systems.Multimeters are available in a wide range of features and prices. Cheap multimeters can cost less than US$10, while laboratory-grade models with certified calibration can cost more than US$5,000.