ULTRA SLIMPAK G168-0001 ® DC Powered AC Input Limit Alarm
... The field configurable G168 limit alarm setpoints can be configured for HI or LO, failsafe or non-failsafe operation. Each of the setpoints have a respective HI or LO deadband. In a tripped condition, the setpoint is exceeded and the appropriate red LED will illuminate. The trip will reset only when ...
... The field configurable G168 limit alarm setpoints can be configured for HI or LO, failsafe or non-failsafe operation. Each of the setpoints have a respective HI or LO deadband. In a tripped condition, the setpoint is exceeded and the appropriate red LED will illuminate. The trip will reset only when ...
Professional Analogue Multi-meter
... - For DCV testing, it’s necessary to observe the correct polarity (red = + / black = -) and connect the two test prods with the test object (battery, circuit, etc.). If the polarity is not correct, no value is displayed. The built-in protective diode prevents the measurement. Stop measuring and meas ...
... - For DCV testing, it’s necessary to observe the correct polarity (red = + / black = -) and connect the two test prods with the test object (battery, circuit, etc.). If the polarity is not correct, no value is displayed. The built-in protective diode prevents the measurement. Stop measuring and meas ...
PDF 60kB - TDK
... 5. Conducted Susceptibility Test EN61000-4-6…………………………………………… 7. Immunity to Magnetic Field Test EN61000-4-8………………. ...
... 5. Conducted Susceptibility Test EN61000-4-6…………………………………………… 7. Immunity to Magnetic Field Test EN61000-4-8………………. ...
Isolated CAN Transceiver with Integrated High Voltage, Bus-Side, Linear Regulator ADM3052
... single 3.3 V or 5 V supply on VDD1, the logic side, and a single 24 V supply provided on V+, the bus side. The ADM3052 creates an isolated interface between the CAN protocol controller and the physical layer bus. It is capable of running at data rates up to 1 Mbps. The device has integrated miswire ...
... single 3.3 V or 5 V supply on VDD1, the logic side, and a single 24 V supply provided on V+, the bus side. The ADM3052 creates an isolated interface between the CAN protocol controller and the physical layer bus. It is capable of running at data rates up to 1 Mbps. The device has integrated miswire ...
Resistors 101 – Instructional Guide
... The voltage coefficient is the change in resistance with applied voltage. This is entirely different and in addition to the effects of self-heating when power is applied. A resistor with a VCR of 100 ppm/V will change 0.1 % over a 10 V change and 1 % over a 100 V change. In the context of a resistor ...
... The voltage coefficient is the change in resistance with applied voltage. This is entirely different and in addition to the effects of self-heating when power is applied. A resistor with a VCR of 100 ppm/V will change 0.1 % over a 10 V change and 1 % over a 100 V change. In the context of a resistor ...
16-Bit, 100 kSPS, Single-Ended PulSAR ADC in MSOP/QFN AD7683
... ADA4941 ADA4841 ADA4941 ADA4841 ADA4841 ADA4841 ...
... ADA4941 ADA4841 ADA4941 ADA4841 ADA4841 ADA4841 ...
Optimization of Voltage Doublers for Energy Harvesting Applications
... number of stages increases due to the increased number of diodes. Therefore, if more than one stage of doubling is required to achieve sufficient input voltage to operate a dc-dc upconverter, then the Cockcroft-Walton solution is usually too inefficient. An alternative solution in such cases is to u ...
... number of stages increases due to the increased number of diodes. Therefore, if more than one stage of doubling is required to achieve sufficient input voltage to operate a dc-dc upconverter, then the Cockcroft-Walton solution is usually too inefficient. An alternative solution in such cases is to u ...
A variable step-down conversion ratio switched capacitor DC–DC
... stacked clocks used in the SC converter. The BGR provides precise bias current and reference voltage for the other circuits. Compared to power converters with both inductive and capacitive energy storage, SC DC–DC converters have several advantageous properties. First, without magnetic components, t ...
... stacked clocks used in the SC converter. The BGR provides precise bias current and reference voltage for the other circuits. Compared to power converters with both inductive and capacitive energy storage, SC DC–DC converters have several advantageous properties. First, without magnetic components, t ...
Discrete devices: FETs - UBC Engineering Physics Project Lab
... Op-amp input voltages (V+, V-) must be at least a few volts away from the power rails (+Vcc, -Vcc). Applying input voltages equal or near the power rails will cause the Op-amp to behave unexpectedly. Rail-to-rail Op-amps are an expensive solution to this limitation. ...
... Op-amp input voltages (V+, V-) must be at least a few volts away from the power rails (+Vcc, -Vcc). Applying input voltages equal or near the power rails will cause the Op-amp to behave unexpectedly. Rail-to-rail Op-amps are an expensive solution to this limitation. ...
MDM750H65E2
... change without prior notice to improve product characteristics. Before ordering, purchasers are advised to contact Hitachi sales department for the latest version of this data sheets. 2. Please be sure to read "Precautions for Safe Use and Notices" in the individual brochure before use. 3. In cases ...
... change without prior notice to improve product characteristics. Before ordering, purchasers are advised to contact Hitachi sales department for the latest version of this data sheets. 2. Please be sure to read "Precautions for Safe Use and Notices" in the individual brochure before use. 3. In cases ...
diagnostics of ignition systems - Journal of electrical engineering
... In the secondary circuit coils is high-voltage diode connected. For each of the cylinders in the moment of switching the primary winding on the secondary side there is a high voltage pulse (1-2kV). In ignition systems with distributor and the cylinder located outside circuit is disconnected. This vo ...
... In the secondary circuit coils is high-voltage diode connected. For each of the cylinders in the moment of switching the primary winding on the secondary side there is a high voltage pulse (1-2kV). In ignition systems with distributor and the cylinder located outside circuit is disconnected. This vo ...
Data Sheet Features General Description
... In most applications, the part does not dissipate much heat due to its high efficiency. However, in some conditions when the part is operating in high ambient temperature with high RDS(ON) resistance and high duty cycles, such as in LDO mode, the heat dissipated may exceed the maximum junction tempe ...
... In most applications, the part does not dissipate much heat due to its high efficiency. However, in some conditions when the part is operating in high ambient temperature with high RDS(ON) resistance and high duty cycles, such as in LDO mode, the heat dissipated may exceed the maximum junction tempe ...
AIC2857F
... voltage and large core loss. By setting an acceptable current ripple of inductor, a suitable inductance can be ...
... voltage and large core loss. By setting an acceptable current ripple of inductor, a suitable inductance can be ...
Chapter 4- Resistance
... The resistor value is the primary concern. The value of the resistor may be indicated by three to five digits. In all cases, the last digit indicates the number of zeros to be added to the preceding digits. In the example given, the last digit (2) indicates the number of zeros to be added to the fir ...
... The resistor value is the primary concern. The value of the resistor may be indicated by three to five digits. In all cases, the last digit indicates the number of zeros to be added to the preceding digits. In the example given, the last digit (2) indicates the number of zeros to be added to the fir ...
Slide 1
... current through an element) of a linear circuit containing more than one independent source, is the algebraic sum the voltage across that element (or the current through that element) due to each independent source acting alone. ...
... current through an element) of a linear circuit containing more than one independent source, is the algebraic sum the voltage across that element (or the current through that element) due to each independent source acting alone. ...
AP Physics Free Response Practice – Circuits 1976B3. In the circuit
... Using only this device and one or more 3-ohm resistors design a circuit so that the device will operate properly when the circuit is connected across a battery of emf 24 volts and negligible internal resistance. Within the dashed-line box in the diagram below, draw the circuit using the symbol for t ...
... Using only this device and one or more 3-ohm resistors design a circuit so that the device will operate properly when the circuit is connected across a battery of emf 24 volts and negligible internal resistance. Within the dashed-line box in the diagram below, draw the circuit using the symbol for t ...
shunts, current shunts, and current-sensing
... A shunt is a resistive device employed to divert most of the current in an electric circuit. The earliest shunts were meter shunts used as external accessories to ammeters allowing one meter to be used for a variety of current levels depending upon which shunt was chosen. These were often massive fo ...
... A shunt is a resistive device employed to divert most of the current in an electric circuit. The earliest shunts were meter shunts used as external accessories to ammeters allowing one meter to be used for a variety of current levels depending upon which shunt was chosen. These were often massive fo ...
Multimeter
A multimeter or a multitester, also known as a VOM (Volt-Ohm meter or Volt-Ohm-milliammeter ), is an electronic measuring instrument that combines several measurement functions in one unit. A typical multimeter would include basic features such as the ability to measure voltage, current, and resistance. Analog multimeters use a microammeter whose pointer moves over a scale calibrated for all the different measurements that can be made. Digital multimeters (DMM, DVOM) display the measured value in numerals, and may also display a bar of a length proportional to the quantity being measured. Digital multimeters are now far more common but analog multimeters are still preferable in some cases, for example when monitoring a rapidly varying value. A multimeter can be a hand-held device useful for basic fault finding and field service work, or a bench instrument which can measure to a very high degree of accuracy. They can be used to troubleshoot electrical problems in a wide array of industrial and household devices such as electronic equipment, motor controls, domestic appliances, power supplies, and wiring systems.Multimeters are available in a wide range of features and prices. Cheap multimeters can cost less than US$10, while laboratory-grade models with certified calibration can cost more than US$5,000.