Shunt Calibration (TN-514)
... Shunt Calibration of Strain Gage Instrumentation shunt-calibration relationships are sometimes required for different sets of circumstances. It is particularly important to distinguish between two modes of shunt calibration which are referred to in this Tech Note, somewhat arbitrarily, as instrument ...
... Shunt Calibration of Strain Gage Instrumentation shunt-calibration relationships are sometimes required for different sets of circumstances. It is particularly important to distinguish between two modes of shunt calibration which are referred to in this Tech Note, somewhat arbitrarily, as instrument ...
Characterisation and Generation of High Impulse Voltages and
... calibration certificate for the scale factor and the time parameters as a result of detailed calibration and other uncertainty contributions which are to be observed in ...
... calibration certificate for the scale factor and the time parameters as a result of detailed calibration and other uncertainty contributions which are to be observed in ...
MAX16060/MAX16061/MAX16062 1% Accurate, Quad-/Hex-/Octal-Voltage µP Supervisors General Description
... All open-drain outputs have internal 30µA pullups that eliminate the need for external pullup resistors. However, each output can be driven with an external voltage up to 5.5V. Other features offered include a manual reset input, a tolerance pin for selecting 5% or 10% input thresholds, and a margin ...
... All open-drain outputs have internal 30µA pullups that eliminate the need for external pullup resistors. However, each output can be driven with an external voltage up to 5.5V. Other features offered include a manual reset input, a tolerance pin for selecting 5% or 10% input thresholds, and a margin ...
PowerScout 3037 Manual PDF
... The communications interface to the meters is an RS-485 serial or Ethernet connection that uses the BACnet Master Slave Token Passing (MS/TP) protocol or Modbus protocol for sending commands and retrieving data. A separate remote terminal unit (RTU), Data Logger, or Building Management and Control S ...
... The communications interface to the meters is an RS-485 serial or Ethernet connection that uses the BACnet Master Slave Token Passing (MS/TP) protocol or Modbus protocol for sending commands and retrieving data. A separate remote terminal unit (RTU), Data Logger, or Building Management and Control S ...
Unit 24
... Portions of this material may have been locally modified and may not have been classroom tested at Dickinson College. ...
... Portions of this material may have been locally modified and may not have been classroom tested at Dickinson College. ...
Datasheet - Texas Instruments
... The battery is charged using a standard Li-Ion charge profile with three phases: precharge, constant current and constant voltage. A voltage-based JEITA compatible battery pack thermistor monitoring input (TS) is included that monitors battery temperature and automatically changes charge parameters ...
... The battery is charged using a standard Li-Ion charge profile with three phases: precharge, constant current and constant voltage. A voltage-based JEITA compatible battery pack thermistor monitoring input (TS) is included that monitors battery temperature and automatically changes charge parameters ...
Energy Meter Standard
... networking of installed meters. However, no pre-installation programming or post installation programming shall be required for this purpose. In such case time of reading for the next layer of meters may vary and the additional time of +3 sec for each added meter layer i.e. for each hop shall be all ...
... networking of installed meters. However, no pre-installation programming or post installation programming shall be required for this purpose. In such case time of reading for the next layer of meters may vary and the additional time of +3 sec for each added meter layer i.e. for each hop shall be all ...
MAX1533/MAX1537 High-Efficiency, 5x Output, Main Power-Supply Controllers for Notebook Computers General Description
... input drops below 10V. Output current sensing provides accurate current limit using a sense resistor. Alternatively, power dissipation can be reduced using lossless inductor current sensing. Internal 5V and 3.3V linear regulators power the MAX1533/MAX1537 and their gate drivers, as well as external ...
... input drops below 10V. Output current sensing provides accurate current limit using a sense resistor. Alternatively, power dissipation can be reduced using lossless inductor current sensing. Internal 5V and 3.3V linear regulators power the MAX1533/MAX1537 and their gate drivers, as well as external ...
3.0-V TO 20-V PMBus SYNCHRONOUS BUCK CONTROLLER TPS40400 FEATURES APPLICATIONS
... (9) All read backs are an average of 16 consecutive measurements – not a rolling average. Time is a delay between parameter updates. (10) Constrained by the resolution of READ_IOUT command. This presents as the greater of 122 µV/ IOUT_CAL_GAIN or 62.5 mA, the resolution of the READ_IOUT command (11) ...
... (9) All read backs are an average of 16 consecutive measurements – not a rolling average. Time is a delay between parameter updates. (10) Constrained by the resolution of READ_IOUT command. This presents as the greater of 122 µV/ IOUT_CAL_GAIN or 62.5 mA, the resolution of the READ_IOUT command (11) ...
BDTIC www.BDTIC.com/infineon Efficient Lighting Intelligent solutions for LED drivers and lamp ballast control
... Thermal shutdown protects the LEDs from permanent damage Linear concept eliminates EMI problems External power stage allows improved heat dissipation in comparison to monolithic drivers Higher count of LEDs possible in a string due to very low overhead voltage Less space needed on PCB as n ...
... Thermal shutdown protects the LEDs from permanent damage Linear concept eliminates EMI problems External power stage allows improved heat dissipation in comparison to monolithic drivers Higher count of LEDs possible in a string due to very low overhead voltage Less space needed on PCB as n ...
Analog Front End (AFE) for Sensing Temperature in Smart Grid
... • For distribution: Transformer protection, motor protection, air circuit breakers, and molded case circuit breakers Since a number of RTDs are connected to one expansion module or protection relay the conversion time of the ADC is important. The temperature is a slow varying signal, so the number o ...
... • For distribution: Transformer protection, motor protection, air circuit breakers, and molded case circuit breakers Since a number of RTDs are connected to one expansion module or protection relay the conversion time of the ADC is important. The temperature is a slow varying signal, so the number o ...
Multimeter
A multimeter or a multitester, also known as a VOM (Volt-Ohm meter or Volt-Ohm-milliammeter ), is an electronic measuring instrument that combines several measurement functions in one unit. A typical multimeter would include basic features such as the ability to measure voltage, current, and resistance. Analog multimeters use a microammeter whose pointer moves over a scale calibrated for all the different measurements that can be made. Digital multimeters (DMM, DVOM) display the measured value in numerals, and may also display a bar of a length proportional to the quantity being measured. Digital multimeters are now far more common but analog multimeters are still preferable in some cases, for example when monitoring a rapidly varying value. A multimeter can be a hand-held device useful for basic fault finding and field service work, or a bench instrument which can measure to a very high degree of accuracy. They can be used to troubleshoot electrical problems in a wide array of industrial and household devices such as electronic equipment, motor controls, domestic appliances, power supplies, and wiring systems.Multimeters are available in a wide range of features and prices. Cheap multimeters can cost less than US$10, while laboratory-grade models with certified calibration can cost more than US$5,000.