• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
AD623 instrumentation amplifier
AD623 instrumentation amplifier

... Low power consumption (1.5 mW at 3 V), wide supply voltage range, and rail-to-rail output swing make the AD623 ideal for battery-powered applications. The rail-to-rail output stage maximizes the dynamic range when operating from low supply voltages. The AD623 replaces discrete instrumentation amplif ...
Adjustment Data MAZDA - 323 - 1.6i
Adjustment Data MAZDA - 323 - 1.6i

OpenStax Physics Text for 2B - Chapter 4
OpenStax Physics Text for 2B - Chapter 4

... everything in this module applies to both DC and AC. Matters become more complex when capacitance is involved. We do consider what happens when capacitors are connected to DC voltage sources, but the interaction of capacitors and other nonresistive devices with AC is left for a later chapter. Finall ...
Digital and Analog I/O
Digital and Analog I/O

RadarTron User`s Manual
RadarTron User`s Manual

LM3448 Phase Dimmable Offline LED Driver with
LM3448 Phase Dimmable Offline LED Driver with

... High voltage devices such as the LM3448 are susceptible to increased leakage currents when exposed to high humidity and high pressure operating environments. Users of this device are cautioned to satisfy themselves as to the suitability of this product in the intended end application and take any ne ...


LM34923 80V, 600 mA Constant On-Time Buck Switching Regulator
LM34923 80V, 600 mA Constant On-Time Buck Switching Regulator

Kinetis-M Two-Phase Power Meter - Reference Design
Kinetis-M Two-Phase Power Meter - Reference Design

... The two-phase power meter reference design is intended for the measurement and registration of active and reactive energies in two-phase networks. It is targeted specifically at the American and Japanese regions. Depending on the target region, it is pre-certified according to different standards; ...
Any path along which electrons can flow is a circuit.
Any path along which electrons can flow is a circuit.

Flag Antenna Construction
Flag Antenna Construction

... value if one had to resort to a fixed resistor instead of Vactrol control. This is pretty much in agreement with K6SE’s article. I feel that the Vactrol method is essential for best performance because, for minor differences in bearing and frequency, different termination values are needed to squeez ...
MAX1121 1.8V, 8-Bit, 250Msps Analog-to-Digital Converter with LVDS Outputs for Wideband Applications
MAX1121 1.8V, 8-Bit, 250Msps Analog-to-Digital Converter with LVDS Outputs for Wideband Applications

... Operating Temperature Range ...........................-40°C to +85°C Junction Temperature ......................................................+150°C Storage Temperature Range .............................-60°C to +150°C Lead Temperature (soldering, 10s) .................................+300°C Max ...
OP27
OP27

35 Electric Circuits
35 Electric Circuits

... 35.6 Combining Resistors in a Compound Circuit For the combination of three 8-ohm resistors, the two resistors in parallel are equivalent to a single 4-ohm resistor. They are in series with an 8-ohm resistor, adding to produce an equivalent resistance of 12 ohms. If a 12-volt battery were connected ...
35 Electric Circuits
35 Electric Circuits

MAX882/MAX883/MAX884 5V/3.3V or Adjustable, Low-Dropout, Low I , 200mA Linear Regulators
MAX882/MAX883/MAX884 5V/3.3V or Adjustable, Low-Dropout, Low I , 200mA Linear Regulators

... The output voltage is set by the following equation: ...
Circuits - Island Physics
Circuits - Island Physics

... battery – The scientific word for two or more cells that are joined together. cell – A chemical source of voltage. The chemicals inside this device react and electrons are pushed out into the circuit. circuit – A complete path that current can travel along. current – The rate of flow of electric cha ...
Digitally-Controllable Audio Filters and Equalizers
Digitally-Controllable Audio Filters and Equalizers

PR‐PUB‐NLH‐183 (Revision 1, Jun 19‐15)  NLH 2015 Prudence Review  Page 1 of 2 Q. 
PR‐PUB‐NLH‐183 (Revision 1, Jun 19‐15)  NLH 2015 Prudence Review  Page 1 of 2 Q. 

... Machines to be tested must be clean and dry. Inspection and insulation resistance tests with acceptable results should be performed before the high-potential tests. Insulation resistance tests should be repeated at the completion of the highpotential tests. When a high-potential test is conducted on ...
Electrochemical Impedance Spectroscopy Primer
Electrochemical Impedance Spectroscopy Primer

BDTIC www.BDTIC.com/infineon Driving High Power LEDs at 350mA
BDTIC www.BDTIC.com/infineon Driving High Power LEDs at 350mA

... breakdown voltage of 30V. If there is a need to test the board with a maximum supply voltage of 40V, please replace the schottky diode SD1 with a suitable breakdown voltage. The ILD4035 incorporates the following protection features: Over-voltage protection, temperature protection and an over-curren ...
KSR-Level sensor KSR-Schwimmer-Magnetschalter KSR Control
KSR-Level sensor KSR-Schwimmer-Magnetschalter KSR Control

service procedure - generator insulation testing
service procedure - generator insulation testing

V m sin (  t )
V m sin ( t )

... Sinusoidal waveform Average and effective value of a sinusoidal waveform An effective value or Root-Mean-Square (RMS) a periodic current (or voltage) is defined as: The value of the DC current (or voltage) which, flowing through a R-ohm resistor delivers the same average power as does the periodic ...
If You have Problems
If You have Problems

< 1 ... 109 110 111 112 113 114 115 116 117 ... 654 >

Multimeter



A multimeter or a multitester, also known as a VOM (Volt-Ohm meter or Volt-Ohm-milliammeter ), is an electronic measuring instrument that combines several measurement functions in one unit. A typical multimeter would include basic features such as the ability to measure voltage, current, and resistance. Analog multimeters use a microammeter whose pointer moves over a scale calibrated for all the different measurements that can be made. Digital multimeters (DMM, DVOM) display the measured value in numerals, and may also display a bar of a length proportional to the quantity being measured. Digital multimeters are now far more common but analog multimeters are still preferable in some cases, for example when monitoring a rapidly varying value. A multimeter can be a hand-held device useful for basic fault finding and field service work, or a bench instrument which can measure to a very high degree of accuracy. They can be used to troubleshoot electrical problems in a wide array of industrial and household devices such as electronic equipment, motor controls, domestic appliances, power supplies, and wiring systems.Multimeters are available in a wide range of features and prices. Cheap multimeters can cost less than US$10, while laboratory-grade models with certified calibration can cost more than US$5,000.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report