• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
auto transformer
auto transformer

... Three winding transformers have been installed (in large numbers) to meet the following conditions: • Transformers with two primary windings and one secondary winding are often used in large generating stations. One generator is being connected to each of the two primary windings, and the power fro ...
design_review
design_review

... Data is sent to and from the iPhone over the headphone audio jack using a Manchester encoded signal. Manchester encoding allows for digital encoding with a sinusoidal analog signal. A positive voltage represents digital “1”, and negative voltage represents digital “0”. Since a long string of 1s or 0 ...
solar photovoltaic installations
solar photovoltaic installations

OPERATING INSTRUCTIONS for Flow Meters of the Series „VHM
OPERATING INSTRUCTIONS for Flow Meters of the Series „VHM

... Flow rate measurement range. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Installing the flow meter. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...
IF 1684 Revision 1
IF 1684 Revision 1

... All components in the fixture are prewired so only line in, neutral, and ground need to be connected in the fixture to the terminals per the wiring diagrams using methods that comply with all applicable codes. Use supply cord with outer sheath diameter in accordance with Table 1. Terminate the equip ...
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE)
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE)

Lect11
Lect11

BD8962MUV
BD8962MUV

... TSZ02201-0J3J0AJ00030-1-2 02.Oct.2014 Rev.002 ...
BH2226F(V) - ROHM Semiconductor
BH2226F(V) - ROHM Semiconductor

BD8967FVM
BD8967FVM

... BD8967FVM is ROHM’s high efficiency step-down switching regulator designed to produce a voltage as low as 3.3V from a supply voltage of 5V. It offers high efficiency with synchronous switches and provides fast transient response to sudden load changes by ...
Installation Manual
Installation Manual

... the transmitter button, this output will become active for 1 second. This is a transistorized, low current ( 300 mA ) output, designed to provide an output only when the transmitter is intentionally operated, such as is the case with remote start add on modules. If you require more than 300mA drive ...
Common-Mode Voltage Eliminated 2-level PWM Inverter
Common-Mode Voltage Eliminated 2-level PWM Inverter

... for high power medium voltage industrial applications because of its inherent advantages offered [1]. Conventional PWM inverters produce alternating common-mode voltage (CMV) in the induction motor drive system [2,3]. This CMV builds up through capacitive coupling between stator and rotor frame resu ...
68 Voltage and Current in Simple Circuits (Voltage Sensor, Current
68 Voltage and Current in Simple Circuits (Voltage Sensor, Current

... coulomb of charge. Current is the volume of electric charge, or the number of charges per second moving past a point in an electric circuit. The unit for current is the ampere and one ampere is one coulomb of charge per second. In a simple circuit of a battery connected to a light bulb, the battery ...
Precision_Power_Art Series A204, A404, AX400
Precision_Power_Art Series A204, A404, AX400

... its surface area. The traditional way to add surface area is to use fins, expanding the radiating surface without increasing the overall dimensions of the amplifier. So why doesn't the Art Series heatsink employ the traditional use of fins since it must adhere to the same rules of thermodynamics tha ...
technical brief - Enphase Energy
technical brief - Enphase Energy

... The M250 has integrated DC and AC cables and connectors. The DC connectors attach to the PV module, while the AC connector attaches directly to the Engage™ Cable. No additional cabling is needed. The Engage Cable is a continuous length of 12 AWG, outdoor rated cable, with integrated connectors for m ...
MAX1761 Small, Dual, High-Efficiency Buck Controller for Notebooks General Description
MAX1761 Small, Dual, High-Efficiency Buck Controller for Notebooks General Description

... Note 2: If V+ is less than 5V, V+ must be connected to VL. If VL is connected to V+, V+ must be between 4.5V and 5.5V. Note 3: DC output accuracy specifications refer to the trip-level error of the error amplifier. The output voltage will have a DC regulation higher than the trip level by 50% of the ...
LTC1435 - High Efficiency Low Noise Synchronous Step
LTC1435 - High Efficiency Low Noise Synchronous Step

... voltage of the SENSE+ and SENSE – pins is below 1.4V and the other is when the SFB pin is below 1.19V. The latter condition is used to assist in secondary winding regulation as described in the Applications Information section. INTVCC/EXTVCC Power Power for the top and bottom MOSFET drivers and most ...
MAX5876 12-Bit, 250Msps, High-Dynamic-Performance, Dual DAC with LVDS Inputs General Description
MAX5876 12-Bit, 250Msps, High-Dynamic-Performance, Dual DAC with LVDS Inputs General Description

... communications applications. Operating from +3.3V and +1.8V supplies, this dual DAC offers exceptional dynamic performance such as 75dBc spurious-free dynamic range (SFDR) at fOUT = 16MHz and supports update rates of 250Msps, with a power dissipation of only 287mW. The MAX5876 utilizes a current-ste ...
26 12 10 Cables, Medium Voltage
26 12 10 Cables, Medium Voltage

HMC349MS8G - SeekDataSheet
HMC349MS8G - SeekDataSheet

MAX8836Z 1.2A PWM Step-Down Converter in General Description
MAX8836Z 1.2A PWM Step-Down Converter in General Description

... feedback network. By taking DC feedback from the LX node through R1 in Figure 1, the usual phase lag due to the output capacitor is removed, making the loop exceedingly stable and allowing the use of very small ceramic output capacitors. To improve the load regulation, resistor R3 is included in the ...
MAX2160/MAX2160EBG ISDB-T Single-Segment Low-IF Tuners General Description Features
MAX2160/MAX2160EBG ISDB-T Single-Segment Low-IF Tuners General Description Features

... 42dB of image rejection. The parts are capable of operating with either high-side or low-side local oscillator (LO) injection. The MAX2160/EBG’s variable-gain amplifiers provide in excess of 100dB of gain-control range. The MAX2160/EBG also include fully monolithic VCOs and tank circuits, as well as ...
LM4559F
LM4559F

... gain decided by the ratio of R1 and R2. OUT is in-phase with IN and is shown in the next expression. OUT=(1+R2/R1)・IN Effectively, this circuit has high input impedance since its input side is the same as that of the operational amplifier. ...
An Improvement of Transient Current Response of Load
An Improvement of Transient Current Response of Load

BD9E151NUX
BD9E151NUX

... make a marked improvement in overall efficiency. Additionally, check that the device chosen is capable of dissipating the power losses. ...
< 1 ... 51 52 53 54 55 56 57 58 59 ... 326 >

Ground loop (electricity)

In an electrical system, a ground loop is an equipment and wiring configuration which results in excessive unwanted current in a conductor connecting two points that are supposed to be at the same electric potential, often ground, but are actually at different potentials.Ground loops are a major cause of noise, hum, and interference in audio, video, and computer systems. They do not in themselves create an electric shock hazard, the inappropriate connections merely create a not necessarily very good instance of Electrical_bonding, which is explicitly required by safety regulations in certain circumstances. In any case the voltage difference between the ground terminals of each item of equipment is small. A severe risk of electric shock occurs when equipment grounds are improperly removed in an attempt to cure the problems thought to be caused by ground loops.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report