• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
RS-485 Application Cheat Sheet
RS-485 Application Cheat Sheet

... The EIA/TIA RS-485 communications standard, an upgrade of RS-422, supports 32 devices (driver/receiver pairs) in a party line or multi-drop mode, on a cable of up to 4,000 feet for balanced differential signal transmissions at a common-mode voltage (Vcm) of -7 to +12 V. You can internally or externa ...
THE EXPANDING PROBLEM OF HIGH FREQUENCY NOISE
THE EXPANDING PROBLEM OF HIGH FREQUENCY NOISE

Current Transformer Grounding
Current Transformer Grounding

... secondary should have a single ground location for each circuit. The single ground is irrespective of the number of current transformers or the chosen grounding location. Utilizing a single ground eliminates the risk of redundant ground loops and associated problems. During normal operation more tha ...
UFC FlatPakTM SERIES 400 Hz GROUND POWER UNIT 20
UFC FlatPakTM SERIES 400 Hz GROUND POWER UNIT 20

... The FlatPakTM Series includes 400 Hz converters specifically designed for installation where space is limited. The units mount “flat” against a wall, and offer the smallest size to power rating ratio in the industry. Also, by using noise reduction technology, Unitron converters are quiet enough to b ...
Fully Integrated TX/RX HV ASIC design for CMUT
Fully Integrated TX/RX HV ASIC design for CMUT

... accurate, and portable mechanical sensor system. A capacitive micro-machined ultrasonic transducer (CMUT) is a strong candidate for a MEMS resonant sensor system with several key advantages [1]. The existing piezoelectric transducer fabrication technology relies on meticulous and labor-intensive ste ...
KEYES 5V Relay Module KY-019
KEYES 5V Relay Module KY-019

... application. It has three pins, the VCC, GND and Signal. It can act as switch if the circuit and the load circuit have different supply voltage. It is commonly use if the load circuit is AC. It is a switch used to connect isolated connection from the circuit using a circuit signal. It has red LED th ...
Ground-Reference Popless Stereo Headphone Driver
Ground-Reference Popless Stereo Headphone Driver

... The G1412 stereo headphone driver is designed for portable equipment where board space is limited. The G1412 uses the dual external power supplies PVDD/NVDD to produce a ground-reference output, eliminating the need for large DC-blocking capacitors, saving cost, board space, and component height. Th ...
Electronic signal converters Micropace™ LMI
Electronic signal converters Micropace™ LMI

... Electronic signal converters Micropace™ LMI Micropace™ Range •The Micropace™ line of rugged, low cost control modules provide you with the ability to proportionally adjust the output of any LMI AA7/AA9/B7/B9/C7/C9 metering pump. •Adjustment can be made by multiplying (MP-500-M), dividing (MP-400-D) ...
What is this third signal wire and what do I do with it? Introduction
What is this third signal wire and what do I do with it? Introduction

ESD Basics
ESD Basics

... Static electricity can build up on objects or people over time through as simple an action as movement. This charge build up can reaches voltages as high as 35000 volts in people. As with any voltage potential, if a conductive path exists between the voltage potential then current will flow. The obj ...
INTRODUCTION TO T&T WIRING CODE
INTRODUCTION TO T&T WIRING CODE

... system is subjected only to that potential difference. • Facilitates the operation of over current devices such as fuses, circuit breakers or relays under ground fault conditions. ...
Senior Design 4006C Group G7 Design Report
Senior Design 4006C Group G7 Design Report

... • the TIA, is a high gain amplifier that converts an input current from the PhotoDiode to an output voltage. •The pair of diodes is used to clamp any input currents above 1mA. •Voltage amplifier converts the single-ended signal into a differential one ...
How to Minimize Noise in High Resolution Measurements
How to Minimize Noise in High Resolution Measurements

Enphase® C250 - Wholesale Solar
Enphase® C250 - Wholesale Solar

... overall energy harvest and system availability along with substantial reductions in material and labor costs. Used with a transformer, the C250 Microinverter System meets the needs of medium and large commercial installations where power distribution is 277 V/480 WYE or medium voltage (MV). With sup ...
Series and Parallel Circuits 1 - Instructor Outline
Series and Parallel Circuits 1 - Instructor Outline

UFC SERIES PwrKartTM 400 Hz AND 270 VDC
UFC SERIES PwrKartTM 400 Hz AND 270 VDC

... Built-In Test Equipment (BITE) and modular construction, Unitron products assure maximum power availability and minimal repair time for the latest military aircraft including the F-22A Raptor and the JSF F-35A. The PwrKart™ Series includes lightweight 115/200 VAC, 400 Hz, 28 VDC, and 270VDC mobile c ...
15.5 Other Practical Considerations
15.5 Other Practical Considerations

Voltage Drop Reference - Western Marine Company
Voltage Drop Reference - Western Marine Company

Power Fundamentals: Linear Regulator Fundamentals
Power Fundamentals: Linear Regulator Fundamentals

Analog Current/Voltage Input to Four Adjustable Trip Level
Analog Current/Voltage Input to Four Adjustable Trip Level

Electric Circuits
Electric Circuits

... • The relationship between voltage, current, and resistance • Current = voltage/resistance • I = V/R • (A) = (V)/(Ω) ...
Circuit Analysis
Circuit Analysis

Micropower Circuit Monitors Positive Supply
Micropower Circuit Monitors Positive Supply

... The inexpensive circuit of Figure 1 converts the load current of a positive power supply to a groundreferenced signal voltage, without recourse to the instrumentation amplifier, extra power supply, and matched sets of resistors typical of such circuits. The output current IO (proportional to supply ...
Rating of Ground Bus in Metal-Enclosed
Rating of Ground Bus in Metal-Enclosed

Technical Reference - Ericson Manufacturing Company
Technical Reference - Ericson Manufacturing Company

... UL Listed - Indicates an item has been tested and approved to the safety standards established by Underwriters’ Laboratories. UL Recognized - Refers to products that have been tested and approved to the safety standards established by Underwriters’Laboratories & are typically used as components of a ...
< 1 ... 311 312 313 314 315 316 317 318 319 ... 326 >

Ground loop (electricity)

In an electrical system, a ground loop is an equipment and wiring configuration which results in excessive unwanted current in a conductor connecting two points that are supposed to be at the same electric potential, often ground, but are actually at different potentials.Ground loops are a major cause of noise, hum, and interference in audio, video, and computer systems. They do not in themselves create an electric shock hazard, the inappropriate connections merely create a not necessarily very good instance of Electrical_bonding, which is explicitly required by safety regulations in certain circumstances. In any case the voltage difference between the ground terminals of each item of equipment is small. A severe risk of electric shock occurs when equipment grounds are improperly removed in an attempt to cure the problems thought to be caused by ground loops.
  • studyres.com © 2025