• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Test Procedure for the LV5683PGEVB Evaluation Board  SANYO Semiconductors
Test Procedure for the LV5683PGEVB Evaluation Board SANYO Semiconductors

... And USB, AUDIO and SWU-OUT are low potential. 2. Measurement Connect VCC/VCC1 cable and GND cable. Bias VCC/VCC1 voltage. Regarding bias voltage range, refer to Application note. Next step remove 3 “Shorted Ring”. Then measure each USB, AUDIO SWU-OUT of voltage and Iq at no load. And then refer to t ...
Ground Resistance Clamp-On Tester - Cole
Ground Resistance Clamp-On Tester - Cole

... and then OL (overload). The value will roll over to 0 after OL is displayed. 4. Once the desired value is set, press the FUNC button a second time to view and adjust the “LO” alarm value. 5. Press the FUNC button three more times to exit the setting mode. 6. The meter will now compare the measured r ...
EMI EMISSIONS
EMI EMISSIONS

... Abrupt output voltage transitions are dictated by ASD semiconductor switching times. Present generation ASDs use Insulated Gate Bipolar Transistors (IGBT) semiconductors with rise/fall times trise < 200 ns and are inherent sources of radiated and conducted EMI. Pulse repetition rate is called carrie ...
FM-Radio Broadcasting
FM-Radio Broadcasting

... Preemphasis is generally used, as described in Chapter 6, to improve the demodulator performance in the presence of noise in the received signal. The receiver most commonly used in FM-radio broadcast is a ...
Ground systems - Arrakis Systems
Ground systems - Arrakis Systems

... A ground loop exists when there is more than one ground path between two pieces of electronic equipment. The two ground paths form a large loop antenna which picks up noise currents, particularly 60 cycle AC. The resistance in the ground paths converts these currents into fluctuating noise voltage d ...
Earth Ground Resistance Measurement
Earth Ground Resistance Measurement

... other ground points. To overcome this challenge the Fall of Potential Method with Current Probe technique is used. ...
Battery-Resistor Circuit SIM Homework II Answer Key
Battery-Resistor Circuit SIM Homework II Answer Key

surge-currrent-filters
surge-currrent-filters

Appendix I
Appendix I

... Another unusual feature is the local feedback of the output stage by the cathode coils of the output transformer. It could be thought that this negative current feedback would raise output resistance of the entire stage. Because of the close coupling of all coils quite the opposite is the case. If ...
How to Wire up an Audio Power www.hifisonix.com
How to Wire up an Audio Power www.hifisonix.com

DP-700 - Accuphase
DP-700 - Accuphase

... digital signal processing circuitry constitutes a moving average filter for straight D/A conversion. Superior quality digital audio interface HS-Link. When Accuphase introduced the ultimate separate-type SA-CD/CD player, the models DP-800 and DC-801, a new epoch in audio history had begun. Garnering ...
SECTION 611 (Pages731 – 736) is deleted and the following... 611 ACCEPTANCE PROCEDURES FOR TRAFFIC CONTROL SIGNALS AND
SECTION 611 (Pages731 – 736) is deleted and the following... 611 ACCEPTANCE PROCEDURES FOR TRAFFIC CONTROL SIGNALS AND

... 611-5.1 General Requirements: After satisfactory completion of all field tests in accordance with 611-4, repair or replace any defective components or work of the installations for a 90 day period after final acceptance in accordance with 5-11. 611-5.2 Contractor’s Responsibilities: During the warra ...
Electric charges in motion Voltage sources Electrical circuits
Electric charges in motion Voltage sources Electrical circuits

CCNA1 3.0-04 Cable Testing
CCNA1 3.0-04 Cable Testing

net4
net4

... – Nearby cables which carry data signals (crosstalk) – Radio frequency interference (RFI), which is noise from other signals being transmitted nearby – Electromagnetic interference (EMI), which is noise from nearby sources such as motors and lights – Laser noise at the transmitter or receiver of an ...
microcontroller based multifunction relay
microcontroller based multifunction relay

HMC586LC4B
HMC586LC4B

... No Connection. These pins may be connected to RF/DC ground. Performance will not be affected. ...
procedure
procedure

Test Procedure for the LV5693PGEVB Evaluation Board  SANYO Semiconductors TEST Procedure
Test Procedure for the LV5693PGEVB Evaluation Board SANYO Semiconductors TEST Procedure

Transtector Power Conditioning with Voltage Regulation
Transtector Power Conditioning with Voltage Regulation

system interface application (apfiff10)
system interface application (apfiff10)

Kirchoff`s Rules
Kirchoff`s Rules

Bulbs in series
Bulbs in series

display
display

EAP-031024 We use M-System`s strain gauge transmitter model
EAP-031024 We use M-System`s strain gauge transmitter model

< 1 ... 264 265 266 267 268 269 270 271 272 ... 326 >

Ground loop (electricity)

In an electrical system, a ground loop is an equipment and wiring configuration which results in excessive unwanted current in a conductor connecting two points that are supposed to be at the same electric potential, often ground, but are actually at different potentials.Ground loops are a major cause of noise, hum, and interference in audio, video, and computer systems. They do not in themselves create an electric shock hazard, the inappropriate connections merely create a not necessarily very good instance of Electrical_bonding, which is explicitly required by safety regulations in certain circumstances. In any case the voltage difference between the ground terminals of each item of equipment is small. A severe risk of electric shock occurs when equipment grounds are improperly removed in an attempt to cure the problems thought to be caused by ground loops.