• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
TECHNICAL NOTE Designing an Evaluation Board for Series 1000
TECHNICAL NOTE Designing an Evaluation Board for Series 1000

... In order to obtain the best device performance, particular attention must be paid to the proximity analog electronics. A proposed circuit that includes a reference voltage, the sensor, decoupling capacitors and output buffers is shown in Figure 1. Optimal acceleration measurements are obtained using ...
PCB Layout Narrative  - Purdue College of Engineering
PCB Layout Narrative - Purdue College of Engineering

DAC,Diodes and TRIACS
DAC,Diodes and TRIACS

... • TRIACs start conducting when a minimum current (gate threshold current) flows into or out of its gate sufficient to turn on relevant junctions in that quadrant of operation • Device remains in “on” state even after gate current is removed so long as current through the device remains above holding ...
LDS8641 - IXYS Power
LDS8641 - IXYS Power

... If V IN falls below 2.3 V but above 1.7 V (typical value), LDS8641 will restart when input voltage rises above 2.3 V called lockout mode. If VIN continues fall below 1.7 V, LDS8641 device will enter shutdown mode.. To restart device, set EN pin logic low for more than 50 ms and logic high after that ...
Zener diodes are used to regulate voltage across small
Zener diodes are used to regulate voltage across small

UTP (Unshielded Twisted Pair)
UTP (Unshielded Twisted Pair)

... Insulation A material which is nonconductive to the flow of electric current. The coating (usually plastic) of a conductor which insulates it from other conductors. Shield A metallic foil or multi-wire screen mesh that is used to prevent electromagnetic fields from penetrating or exiting a transmiss ...
Grounding Shielding
Grounding Shielding

Let Your Light Shine
Let Your Light Shine

... the power factor, the less efficient the circuit and the higher the overall operating cost. The overall operating cost is increased because every component in the system, such as transformer and conductor sizes, must be sized for the higher current caused by lower ...
The Oscilloscope: Basic Features & Functions
The Oscilloscope: Basic Features & Functions

Upgrading the Rotor Ground Fault Protection on Electric Generators
Upgrading the Rotor Ground Fault Protection on Electric Generators

overcurrent protection and voltage sag coordination
overcurrent protection and voltage sag coordination

Tue., Mar. 22 notes - UA Atmospheric Sciences
Tue., Mar. 22 notes - UA Atmospheric Sciences

... where the magnetic field is zero (B fields from currents flowing in the right and left hand sides of the cylinder point in opposite directions and cancel). The measuring instrumentation is placed in a metal box, a Faraday cage, at the top part of the figure. Signals can then be sent out on fiber opt ...
The Amplifier Input Protection Circuit for a Intraoperative Evoked
The Amplifier Input Protection Circuit for a Intraoperative Evoked

LM22670,LM22671,LM22672,LM22673,LM22674, LM22675,LM22676,LM22677,LM22678,LM22679, LM25005,LM3578A,LM5000,LM5001,LM5002,
LM22670,LM22671,LM22672,LM22673,LM22674, LM22675,LM22676,LM22677,LM22678,LM22679, LM25005,LM3578A,LM5000,LM5001,LM5002,

... change the large signal behavior of the power supply, yet has to be large enough, so that it can be recognized once it travels around the loop. However it must not cause the loop to change its behavior. For example, some devices have output over voltage protection thresholds reflected at the feedbac ...
A low-power system for audio noise suppression: a cooperative
A low-power system for audio noise suppression: a cooperative

... New advances in analog VLSI circuits have made it possible to perform operations that more closely reflect those done in DSP applications, or that are desired in future DSP applications [ I , 2, 3, 4, 5 , 6 , 71. Fulther, analog circuits and systems can be pmgrummuble, reconfigurable, adaptive, and ...
PRECISION TURBINE METERS G2 SERIES
PRECISION TURBINE METERS G2 SERIES

How to make a MIL eliminator- Disclaimer Introduction About the O2
How to make a MIL eliminator- Disclaimer Introduction About the O2

... efficiency when converting the three major pollutants (CO, HC, NOX) into harmless emissions (CO2, H2O, N, H). The computer can only use the sensor's output information under certain conditions. First, the sensor must be hot to produce a normal signal. (600°F). This is why most sensors today have bui ...
lines of 150 kV XLPE power cables at 2.5 m depth
lines of 150 kV XLPE power cables at 2.5 m depth

Noise/ SI becoming increasing critical
Noise/ SI becoming increasing critical

... Crosstalk is a well-known phenomenon at all levels of electronic packaging from system level cables through wires on printed circuit board ,multi-chipmodules to chip level routing and inside of VLSI interconnection. Crosstalk causes undesired signal noise to be coupled from an active line (Aggressor ...
EMX18
EMX18

... (such as audio visual equipment, office-automation equipment, communications devices, electrical appliances and electronic toys). Should you intend to use these products with equipment or devices which require an extremely high level of reliability and the malfunction of with would directly endanger ...
Evaluates:  MAX1703 MAX1703 Evaluation Kit ________________General Description ____________________________Features
Evaluates: MAX1703 MAX1703 Evaluation Kit ________________General Description ____________________________Features

... CLK/SEL pin can be driven by an external source to select the power mode or a 200kHz to 400kHz signal to control the switching frequency. ...
Grounding System For Electric Fences
Grounding System For Electric Fences

... contact a “hot” wire and a grounded wire and thereby receive a shock, alternating fence wires may be electrified and grounded. However, while being more effective, it may cause maintenance problems as any debris that may contact the fence wires will more easily short out the circuit then if contacti ...
earthing and earth fault protection
earthing and earth fault protection

unit 3 class
unit 3 class

HF Mobile Vertical Design
HF Mobile Vertical Design

< 1 ... 212 213 214 215 216 217 218 219 220 ... 326 >

Ground loop (electricity)

In an electrical system, a ground loop is an equipment and wiring configuration which results in excessive unwanted current in a conductor connecting two points that are supposed to be at the same electric potential, often ground, but are actually at different potentials.Ground loops are a major cause of noise, hum, and interference in audio, video, and computer systems. They do not in themselves create an electric shock hazard, the inappropriate connections merely create a not necessarily very good instance of Electrical_bonding, which is explicitly required by safety regulations in certain circumstances. In any case the voltage difference between the ground terminals of each item of equipment is small. A severe risk of electric shock occurs when equipment grounds are improperly removed in an attempt to cure the problems thought to be caused by ground loops.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report