• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Lecture 27
Lecture 27

... History of the Discovery of Electromagnetic Induction In 1825, J. Colladon (who first measured sound speed), had a coil connected to a galvanometer and moved a large magnet nearby, BUT since his magnetic field would affect his galvanometer, he moved the meter to the next room. So when he moved the ...
EMX2
EMX2

... (such as audio visual equipment, office-automation equipment, communications devices, electrical appliances and electronic toys). Should you intend to use these products with equipment or devices which require an extremely high level of reliability and the malfunction of with would directly endanger ...
Automatic Remote Control and Data Acquisition for Experimental
Automatic Remote Control and Data Acquisition for Experimental

... voltages individually. In general, any type of applied voltage pattern can be realized by this functionality. Fig. 5 shows an example of the applied voltage pattern. Basically, the control software reads this setup and outputs the appropriate control voltage between 0 and 10V through the NI DAQ anal ...
document
document

NEMA Evaluating Water damaged Electrical Equipment
NEMA Evaluating Water damaged Electrical Equipment

pdfnew/aob2og01?
pdfnew/aob2og01?

... and return-path pair: Two-Wires. If the conversation between the two persons were separated such that each half of the conversation used a separate electrical circuit, there would be four-wires; two for each. All our lives in analog audio, we have used four-wire circuits, even for non-intercom uses. ...
application note uc3842/3/4/5 provides low-cost current
application note uc3842/3/4/5 provides low-cost current

... reaches a threshold established by the error signal. In this way the error signal actually controls peak inductor current. This contrasts with conventional schemes in which the error signal directly controls pulse width without regard to inductor current. Several performance advantages result from t ...
Chapter 1 General ARTICLE 100 Definitions
Chapter 1 General ARTICLE 100 Definitions

... Connector, Pressure (Solderless). A device that establishes a connection between two or more conductors or between one or more conductors and a terminal by means of mechanical pressure and without the use of solder. Continuous Load. A load where the maximum current is expected to continue for 3 hour ...
ENG17 - SS14 - Lecture 3 - Resistive Circuits and Nodal
ENG17 - SS14 - Lecture 3 - Resistive Circuits and Nodal

LXM1623-12-4x
LXM1623-12-4x

... output current, they can also be actively set. Using a open collector or open drain logic signal will allow you to reduce the lamp current for situations where greater dim range is required, as an example in nighttime situations. In conjunction with a light sensor or other timer the panel could be s ...
AN-740 APPLICATION NOTE
AN-740 APPLICATION NOTE

... system grounds connected to the bus and separated by several meters or more will be at the same potential. Because these grounds are unlikely to be at the same potential, current will flow between these points, and this unintended current flow can damage or destroy components. ...
Bipolar Transistor 20V, 3A VCE(sat);130mV typ. PNP Single CPH6
Bipolar Transistor 20V, 3A VCE(sat);130mV typ. PNP Single CPH6

... aerospace instrument, nuclear control device, burning appliances, transportation machine, traffic signal system, safety equipment etc.) that shall require extremely high level of reliability and can directly threaten human lives in case of failure or malfunction of the product or may cause harm to h ...
What Do We Know About Stray Voltage?
What Do We Know About Stray Voltage?

... fields caused by current flowing on the farm grounding system. Problems with utility and farm wiring can increase both the voltage on the neutral wire as well as the current flowing on the grounding system. The electric and magnetic fields produced by these currents are not perceptible to animals or ...
SWITCH MONITORS
SWITCH MONITORS

... It is set to return an analogue value of 4 in the event of an open or short-circuit fault and 16 during normal operation. The status of the inputs is reported by means of two input bits. The change-over contacts are operated by an output bit. The Input/Output unit is fitted with a bi-directional sho ...
Powerpoint
Powerpoint

A 4Gb/s/ch 356fJ/b 10mm equalized on-chip
A 4Gb/s/ch 356fJ/b 10mm equalized on-chip

Site Considerations for Equipment Installation, Grounding
Site Considerations for Equipment Installation, Grounding

a 750 MHz, 3.8 mA 10 ns Switching Multiplexers AD8180/AD8182*
a 750 MHz, 3.8 mA 10 ns Switching Multiplexers AD8180/AD8182*

... The AD8180 and AD8182 video multiplexers are designed for fast-switching (10 ns) and wide bandwidth (> 750 MHz). This performance is attained with low power dissipation (3.8 mA per active channel) through the use of proprietary circuit techniques and a dielectrically-isolated complementary bipolar p ...
Three-Dimensional Animations of Power
Three-Dimensional Animations of Power

... immediately apparent, and in fact make the very idea of violating it as counter-intuitive as an M.C. Escher drawing [6]; they allow semi-quantitative estimations of relative and absolute voltage drops [7]; and they provide an intuitive analogy between gravitational potential energy and electrical po ...
Chapter 1.5.2 - Digilent Learn site
Chapter 1.5.2 - Digilent Learn site

... The process of measuring a physical parameter will almost invariably change the parameter being measured. This effect is both undesirable and, in general, unavoidable. One goal of any measurement is to affect the parameter being measured as little as possible. The above statement is true of voltage ...
SA 20.6: 5GSample/s Track-Hold and 3GSample/s Quasi-Sample-Hold ICs A. Hülsmann, T. Jakobus
SA 20.6: 5GSample/s Track-Hold and 3GSample/s Quasi-Sample-Hold ICs A. Hülsmann, T. Jakobus

Rectangular Wave Delta Modulation Buck Regulator for Voltage Regulator Modules
Rectangular Wave Delta Modulation Buck Regulator for Voltage Regulator Modules

... facilitate the required high performance control circuitries such as amplifier, saw-tooth generator, oscillator, A/D converter and an embedded controller in fully digital control. Function of the wave generator circuit is always critical under modern low voltage environment and having power supply v ...
ACS750xCA-075 - Allegro Microsystems
ACS750xCA-075 - Allegro Microsystems

... Sensitivity (Sens). The change in device output in response to a 1 A change through the primary conductor. The sensitivity is the product of the magnetic circuit sensitivity (G / A) and the linear IC amplifier gain (mV/G). The linear IC amplifier gain is programmed at the factory to optimize the sen ...
DSC Lab 2: Force and Displacement Measurement Page 1
DSC Lab 2: Force and Displacement Measurement Page 1

Real Analog - Circuits 1 Chapter 2: Lab Projects
Real Analog - Circuits 1 Chapter 2: Lab Projects

... This is not a good way to get an accurate estimate of the internal resistance of the voltmeter, but it should give you an idea of the overall concepts involved. It is likely that the Analog Discovery internal resistance will be significantly lower than the internal resistance of most commercially av ...
< 1 ... 186 187 188 189 190 191 192 193 194 ... 326 >

Ground loop (electricity)

In an electrical system, a ground loop is an equipment and wiring configuration which results in excessive unwanted current in a conductor connecting two points that are supposed to be at the same electric potential, often ground, but are actually at different potentials.Ground loops are a major cause of noise, hum, and interference in audio, video, and computer systems. They do not in themselves create an electric shock hazard, the inappropriate connections merely create a not necessarily very good instance of Electrical_bonding, which is explicitly required by safety regulations in certain circumstances. In any case the voltage difference between the ground terminals of each item of equipment is small. A severe risk of electric shock occurs when equipment grounds are improperly removed in an attempt to cure the problems thought to be caused by ground loops.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report