• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
26 05 13 Medium Voltage Cables
26 05 13 Medium Voltage Cables

Longitudinal Output Voltage Limitations
Longitudinal Output Voltage Limitations

MIC33163/4 General Description Features 4MHz, 1A, Buck Regulator with Integrated
MIC33163/4 General Description Features 4MHz, 1A, Buck Regulator with Integrated

Series 9180/ 9270 Power Amplifier
Series 9180/ 9270 Power Amplifier

LTC1758-1/LTC1758-2 - RF Power Controllers with 250kHz Control Loop Bandwidth and 40dB Dynamic Range.
LTC1758-1/LTC1758-2 - RF Power Controllers with 250kHz Control Loop Bandwidth and 40dB Dynamic Range.

... connected between the RF coupling capacitor (33pF), and ground at the side connected to the directional coupler. If the termination is placed at the LTC1758 RF pin, then the 68Ω resistor must be connected to VIN since the detector is referenced to VIN. Termination components should be placed adjacen ...
All about EMI filters - TDK
All about EMI filters - TDK

... to the in-phase common-mode noise on each ac conductor. In addition, the Y-capacitors (CY1 and CY2) shunt or bypass the high-frequency common mode noise to ground. DMN on each ac conductor is suppressed by the two X-capacitors (CX1 and CX2), which tend to neutralize the out-of-phase high-frequency D ...
Aid troubleshooting
Aid troubleshooting

... Both of these techniques rely on the assumption that equal power to the alternator shunt field will yield equal output currents. This will only happen at equal alternator speeds. Any significant difference will result in the bulk of the current being carried by the channel — with the lowest line res ...
All about EMI filters - Digi
All about EMI filters - Digi

EEEE 381 Lab 4 Differential Amp - RIT - People
EEEE 381 Lab 4 Differential Amp - RIT - People

exp04_add
exp04_add

... • The inputs are connected to what is essentially an open circuit ...
A DESIGNERS GUIDE TO THE L200 VOLTAGE REGULATOR
A DESIGNERS GUIDE TO THE L200 VOLTAGE REGULATOR

... current flowing through T1 and, in any case, this should not exceed the maximum current through R2 under automatic operation. The circuit shown with a small modification can also be used for dimmers other than in a car. Fig. 15 shows the modification needed. The zener diode should have a VF ≥ 2.5 V ...
UCC3884 数据资料 dataSheet 下载
UCC3884 数据资料 dataSheet 下载

... When required the linear positive slope of the CT voltage could be buffered and used to provide slope compensation into the CS pin. OUT: The output of the controller. The peak source current is 0.5 A and the peak sink current is 1.0 A. The faults listed under the CSS description turn off this output ...
232D Electrical Safety Analyzer
232D Electrical Safety Analyzer

Tech Short 16 - Detectors and Discriminators
Tech Short 16 - Detectors and Discriminators

... The Foster-Seeley discriminator is popular because it is simple and less critical in its operation than other types. However, as it is sensitive to amplitude variations on the input signal, it requires a limiter stage preceding it which adds to the overall cost and complexity of the circuit. At the ...
WIRING DIAGRAM INFORMATION
WIRING DIAGRAM INFORMATION

8W-01 WIRING DIAGRAM INFORMATION
8W-01 WIRING DIAGRAM INFORMATION

... CAUTION: Most of the electrical components used in today’s vehicles are Solid State. When checking resistance in these circuits use a meter with a 10 - megohm or greater impedance rating. In addition, make sure the power is disconnected from the circuit. Circuits that are powered up by the vehicle’s ...
[56] New“ Cm“ $351??? $11?` 32351351113252? 165E321
[56] New“ Cm“ $351??? $11?` 32351351113252? 165E321

isolation transformer
isolation transformer

6.0 - Electronic Circuits
6.0 - Electronic Circuits

... excellent linearity derived from use of very high voltage on the collector B. A low-noise VHF or UHF amplifier relying on ...
Voltage ratings 1.3MB
Voltage ratings 1.3MB

... be used on circuits not exceeding 300V between conductors or single-phase line-toneutral loads not exceeding 300V. • NEC 240.60(B) requires fuseholders to reject fuses with lower voltage ratings. • NEC 240.60(C) requires the voltage rating to be marked on the fuse barrel or label. • NEC 240.61 allow ...
FNA21012A 1200 V Motion SPM 2 Series F
FNA21012A 1200 V Motion SPM 2 Series F

... (with the external sense resistance and RC filter connection) c1 : Normal operation: IGBT ON and carrying current. c2 : Short-circuit current detection (SC trigger). c3 : All low-side IGBTs gate are hard interrupted. c4 : All low-side IGBTs turn OFF. c5 : Fault output operation starts with a fixed p ...
Explosion Proof E018 Flow monitor / Totalizer
Explosion Proof E018 Flow monitor / Totalizer

AD8561 Data Sheet
AD8561 Data Sheet

LTC1069-6 - Single Supply, Very Low Power, Elliptic Lowpass Filter
LTC1069-6 - Single Supply, Very Low Power, Elliptic Lowpass Filter

... Single 3V Supply Operation with Output Buffer 3.3V ...
Voltage profile - Mon`s group Sydney
Voltage profile - Mon`s group Sydney

... Voltage control All modern transmission systems with the exception of the constant current system, operate at a constant voltage . It is essential for the satisfactory operation of the consumer’s apparatus that the vltage be kept within narrow limit. Voltage drop The conductor must operate so that w ...
< 1 ... 122 123 124 125 126 127 128 129 130 ... 326 >

Ground loop (electricity)

In an electrical system, a ground loop is an equipment and wiring configuration which results in excessive unwanted current in a conductor connecting two points that are supposed to be at the same electric potential, often ground, but are actually at different potentials.Ground loops are a major cause of noise, hum, and interference in audio, video, and computer systems. They do not in themselves create an electric shock hazard, the inappropriate connections merely create a not necessarily very good instance of Electrical_bonding, which is explicitly required by safety regulations in certain circumstances. In any case the voltage difference between the ground terminals of each item of equipment is small. A severe risk of electric shock occurs when equipment grounds are improperly removed in an attempt to cure the problems thought to be caused by ground loops.