• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
10-Bit, 210 MSPS TxDAC Digital-to-Analog Converter AD9740W
10-Bit, 210 MSPS TxDAC Digital-to-Analog Converter AD9740W

... fCLOCK = 25 MSPS; fOUT = 1.00 MHz fCLOCK = 50 MSPS; fOUT = 2.00 MHz fCLOCK = 65 MSPS; fOUT = 2.00 MHz fCLOCK = 125 MSPS; fOUT = 2.00 MHz Signal-to-Noise Ratio fCLOCK = 65 MSPS; fOUT = 5 MHz; IOUTFS = 20 mA fCLOCK = 65 MSPS; fOUT = 5 MHz; IOUTFS = 5 mA fCLOCK = 125 MSPS; fOUT = 5 MHz; IOUTFS = 20 mA ...
AVQ100-24S05-4L
AVQ100-24S05-4L

... Soldering The product is intended for standard manual or wave soldering. When wave soldering is used, the temperature on pins is specified to maximum 260°C for maximum 7s. When soldering by hand, the iron temperature should be maintained at 300°C ~ 380°C and applied to the converter pins for less th ...
Design of Low-Power Adiabatic 32X32 Content Addressable
Design of Low-Power Adiabatic 32X32 Content Addressable

... as three transistors for the comparison circuits. The two pairs of access transistors are enabled by WWL (write word-line) and RWL (read word-line) for writing and comparison operations, respectively. The power supply of CAM cells is connected to a fixed DC voltage (VDD). The CAM array consists of m ...
Low-Power Differential Line Driver and
Low-Power Differential Line Driver and

... Supply voltage range, VCC (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −0.3 V to 7 V Input voltage range, VI (A, B)(see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −10 V to 15 V Voltage ...
Catalog News LV 1 N 06/2008 EN
Catalog News LV 1 N 06/2008 EN

Current Sharing with Power Supplies | CUI Inc
Current Sharing with Power Supplies | CUI Inc

BD35310316
BD35310316

1 - CERN
1 - CERN

... Total length of cable can vary from 78.5m up to 128.5 m depending on chamber position. Each HV module has one output connector: 22-pin REDEL (KLG.H22.LLZG type). Each module is supplying one pair of CSCs (one Backward and one Forward – see Fig. 2). Except the 12 HV lines, there are 4 ground lines an ...
Aalborg Universitet Droop-free Distributed Control for AC Microgrids
Aalborg Universitet Droop-free Distributed Control for AC Microgrids

... it requires a fully connected communication network. The master node in the networked master-slave methods [46]–[48] is still a single point-of-failure. Distributed cooperative control is recently introduced for AC [49]–[51] and DC microgrids [52]–[55]. Distributed control of AC microgrids are also ...
Thunder Tarp Operation Instructions Rev G
Thunder Tarp Operation Instructions Rev G

Solar circuit protection application guide no. 10191
Solar circuit protection application guide no. 10191

... zone outside of which the potential for shock has been mitigated. Conductors more than 5 feet inside a building or more than 10 feet from an array will be limited to a maximum of 30 V and 240VA within 10 seconds of activation of shutdown. Ten seconds allows time for any dc capacitor banks to dischar ...
tps72501.pdf
tps72501.pdf

... The TPS725xx family of 1-A low-dropout (LDO) linear regulators has fixed voltage options available that are commonly used to power the latest DSPs, FPGAs, and microcontrollers. An adjustable option ranging from 1.22 V to 5.5 V is also available. The integrated supervisory circuitry provides an activ ...
Aalborg Universitet Advanced Control Architectures for Intelligent MicroGrids, Part I
Aalborg Universitet Advanced Control Architectures for Intelligent MicroGrids, Part I

Quadra (VL-1000 750 Kb)
Quadra (VL-1000 750 Kb)

Advanced Control Architectures for Intelligent MicroGrids, Part I
Advanced Control Architectures for Intelligent MicroGrids, Part I

... could be operated without the use of phase-locked loops (PLLs), and that total load real- and reactive-power could be shared based on the converter ratings. Subsequent work [3], [4] extended the droop concept to ensure sharing of harmonic currents of non-linear loads. This was done by extending the ...
Understanding Solar PV Permitting and Inspecting in New York State
Understanding Solar PV Permitting and Inspecting in New York State

... One of the more challenging aspects of solar PV system design and installation is thoroughly grounding and bonding the system in accordance with the NEC. The grounding electrode conductor (GEC) is the reference ground that establishes the voltage relationships between the ungrounded conductors and e ...
owner`s manual
owner`s manual

A Tariff for Reactive Power - Department of Electrical Engineering
A Tariff for Reactive Power - Department of Electrical Engineering

... costs have historically been included in the revenue requirement of the transmission or distribution system operator and recovered through cost-of-service rates. By contrast, conventional generator costs are typically recovered through the energy market. Dynamic sources at the distribution level, wh ...
How to Specify the TS1000-SP Crosswalk System Controller
How to Specify the TS1000-SP Crosswalk System Controller

Power supply module PS 60W 24/48/60VDC
Power supply module PS 60W 24/48/60VDC

... Siemens offers IT security mechanisms for its automation and drive product portfolio in order to support the safe operation of the plant/machine. We recommend that you inform yourself regularly on the IT security developments regarding your products. You can find information on this on the Internet ...
- aes journals
- aes journals

... fs - Switching frequency [Hz] Ton - switch turn-on time [s] Toff - switch turn-off time [s] Switching also causes an EMI problem, because a large amount of di/dt and dv/dt is generated in the process. By raising the switching frequency, can reduce the size of a transformer and filter, which helps bu ...
RT8059 - Richtek
RT8059 - Richtek

... This formula has a maximum at VIN = 2VOUT, where I RMS = I OUT/2. This simple worst-case condition is commonly used for design because even significant deviations do not result in much difference. Note that ripple current ratings from capacitor manufacturers are often based on only 2000 hours of lif ...
Answer all questions PART A – (10*2=20marks) 1. What are the
Answer all questions PART A – (10*2=20marks) 1. What are the

AMS4123 数据手册DataSheet 下载
AMS4123 数据手册DataSheet 下载

... AMS4123 is a switching regulator capable to deliver up to 2A and one LDO rated for 1A output in a single SO-8 EDP package. The switching regulator is Internally Compensated internal Soft Start to reduce to minimum external components. The regulator has hiccup current limit and thermal protection. Th ...
MAX8875 150mA, Low-Dropout Linear Regulator with Power-OK Output General Description
MAX8875 150mA, Low-Dropout Linear Regulator with Power-OK Output General Description

... A P-channel MOSFET pass transistor allows its 85µA supply current to remain independent of the load, making this device ideal for battery-operated portable equipment such as PCS phones, cellular phones, cordless phones, and modems. The MAX8875 features a power-OK (POK) output that indicates when the ...
< 1 ... 92 93 94 95 96 97 98 99 100 ... 384 >

Solar micro-inverter



A solar micro-inverter, or simply microinverter, is a device used in photovoltaics that converts direct current (DC) generated by a single solar module to alternating current (AC). The output from several microinverters is combined and often fed to the electrical grid. Microinverters contrast with conventional string and central solar inverters, which are connected to multiple solar modules or panels of the PV system.Microinverters have several advantages over conventional inverters. The main advantage is that small amounts of shading, debris or snow lines on any one solar module, or even a complete module failure, do not disproportionately reduce the output of the entire array. Each microinverter harvests optimum power by performing maximum power point tracking for its connected module. Simplicity in system design, simplified stock management, and added safety are other factors introduced with the microinverter solution.The primary disadvantages of a microinverter include a higher initial equipment cost per peak watt than the equivalent power of a central inverter, and increased installation time since each inverter needs to be installed adjacent to a panel (usually on a roof). This also makes them harder to maintain and more costly to remove and replace (O&M). Some manufacturers have addressed these issues with panels with built-in microinverters.A type of technology similar to a microinverter is a power optimizer which also does panel-level maximum power point tracking, but does not convert to AC per module.
  • studyres.com © 2025