• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
arduino1
arduino1

... http://www.arduino.cc/en/Tutorial/Blink */ ...
Optimal DC Power Distribution System Design for Data Center with
Optimal DC Power Distribution System Design for Data Center with

... Figure 27: Standby AC UPS System diagram. ................................................................. 37 Figure 28: New Designed Standby DC UPS System diagram ......................................... 38 Figure 29: Total semiconductor power losses depending on the numbers of parallel switches ...
Efficiency improvement with silicon carbide based power modules
Efficiency improvement with silicon carbide based power modules

... From the calculated results in this example, the advantages of SiC based devices can be observed immediately: • For applications which treat efficiency as first priority, the efficiency of the converter at fsw=20kHz can be increased by 1,1% by utilizing SiC diode with IGBT if same output power is ma ...
Part II - Ohio State ECE - The Ohio State University
Part II - Ohio State ECE - The Ohio State University

AND8474 - Implementing a 310 W Power Supply with
AND8474 - Implementing a 310 W Power Supply with

... the regulated bulk voltage is close to the peak of sinusoidal input. To ensure the operation of LLC converter, the start--up level of bulk voltage is usually designed at below the peak value of the sinusoidal input line. It has a risk that the bulk voltage at start--up phase might be too low to prov ...
Revision A - 1/13/96
Revision A - 1/13/96

... UPS will track the bypass when the bypass power is within the frequency synchronization window as specified in the output frequency regulation, or when returning to a free-running condition. System Overload: 1. The UPS module shall be capable of supplying regulated output voltage during overloads of ...
DS1181L 20MHz to 134MHz Spread-Spectrum Clock Modulator for LCD Panels General Description
DS1181L 20MHz to 134MHz Spread-Spectrum Clock Modulator for LCD Panels General Description

... optimization. In addition, through an enable pin the dithering can be enabled or disabled for easy comparison of system performance during EMI testing. This same input pin also allows the DS1181L output to be three-stated. By dithering the system clock, all the address, data, and timing signals gene ...
MAX1858A/MAX1875A/MAX1876A Dual 180° Out-of-Phase Buck Controllers with Sequencing/Prebias Startup and POR General Description
MAX1858A/MAX1875A/MAX1876A Dual 180° Out-of-Phase Buck Controllers with Sequencing/Prebias Startup and POR General Description

... can be set to generate an in-phase, or 90° out-ofphase, clock signal for synchronization with additional controllers. This allows two controllers to operate either as an interleaved two- or four-phase system with each output shifted by 90°. The MAX1858A/MAX1875A/ MAX1876A feature soft-start. The MAX ...
MAX1636 Low-Voltage, Precision Step-Down Controller for Portable CPU Power General Description
MAX1636 Low-Voltage, Precision Step-Down Controller for Portable CPU Power General Description

... adapted to meet a wide range of applications with inputs up to 30V by substituting components from Table 1. These circuits represent a good set of tradeoffs between cost, size, and efficiency, while staying within the worst-case specification limits for stressrelated parameters, such as capacitor ri ...
BUF11705 22-V Supply, 10+1 Channel Gamma Correction Buffer FEATURES
BUF11705 22-V Supply, 10+1 Channel Gamma Correction Buffer FEATURES

... (1) Stresses beyond those listed under absolute maximum ratings may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated under recommended operating conditions is not implied. Exposure to a ...
4.1 Cross coupled sense amplifier flip-flop
4.1 Cross coupled sense amplifier flip-flop

... two comparators are used to produce the signals X and Y, by making use of the inputs D and DB and the outputs Q1 and QB1. If D is different from the output Q1 then X will be pulled up to high and Y to be low. The clock signal will pass through as CL since the transistor CN3 is turned on, the clock s ...
D. J. Perreault and V. Caliskan, “A New Design for Automotive Alternators,” SAE Paper 2000-01-C084, 2000 International Congress on Transportation Electronics (Convergence 2000) , Detroit, MI, Oct. 2000, pp. 583-594.
D. J. Perreault and V. Caliskan, “A New Design for Automotive Alternators,” SAE Paper 2000-01-C084, 2000 International Congress on Transportation Electronics (Convergence 2000) , Detroit, MI, Oct. 2000, pp. 583-594.

... present an experimental evaluation and assessment of this new approach, including an examination of peak and average power capability, losses and efficiency, and manufacturing implications. ...
MM74C925 * MM74C926 4-Digit Counters with Multiplexed 7
MM74C925 * MM74C926 4-Digit Counters with Multiplexed 7

rucksack enhanced portable power system
rucksack enhanced portable power system

Power Transducer Series 50
Power Transducer Series 50

... For analog voltage outputs the external resistance is in parallel with the internal resistance. The specified accuracy is only applicable for the given load value. With an open output circuit the output voltage for POWER 50 transducers is limited to 30 V. Mains type: see Connection method Mains sync ...
Product Guide
Product Guide

PSC30 - Eltek
PSC30 - Eltek

LM2676 - Texas Instruments
LM2676 - Texas Instruments

... Simple-to-Design, High Efficiency (>90%) StepDown Switching Regulators Efficient System Preregulator for Linear Voltage Regulators Battery Chargers ...
GM862-QUAD / PY Hardware User Guide
GM862-QUAD / PY Hardware User Guide



... the application of power to the heating elements using voltage modulation. The result is a smooth and efficient use of power to heat the water. This advanced control technology is extremely important in eliminating light flicker and fluctuations within the home or building. Also, the Seisco heater w ...
YTEC CORP.
YTEC CORP.

... LX EXPANSION CHASSIS These units have the same motherboards as the Mainframes but do not have built-in power supplies or Control Modules. They are powered and controlled from a single MESA Control Mainframe as described in the MESA Bulletin. Larger configurations can be created from up to 16 Expansi ...
Users and designers are faced with challenges when
Users and designers are faced with challenges when

Titre aliquando tempo tatum commentum
Titre aliquando tempo tatum commentum

... XBOX3 TEST STAND AT CERN  XBOX3 will use four Medium Power X-band klystrons recombined and compressed to produce a 50 MW power level  This smart concept is well adapted to the reliability and affordability we are looking for and it will constitute the basis of our study ...
MRFIC1859 Dual-Band/GSM 3.6 V Integrated Power Amplifier
MRFIC1859 Dual-Band/GSM 3.6 V Integrated Power Amplifier

1st industrialized 1200V SiC JFET module for high energy efficiency
1st industrialized 1200V SiC JFET module for high energy efficiency

... efficiency exceeds 99%. Apart from the efficiency point of view, the JFET module is ideally suited for power electronic designs with high switching frequencies targeting the decrease of passives volume for achieving high power densities and lowered overall system costs. Lab-tests with a SiC JFET mod ...
< 1 ... 57 58 59 60 61 62 63 64 65 ... 384 >

Solar micro-inverter



A solar micro-inverter, or simply microinverter, is a device used in photovoltaics that converts direct current (DC) generated by a single solar module to alternating current (AC). The output from several microinverters is combined and often fed to the electrical grid. Microinverters contrast with conventional string and central solar inverters, which are connected to multiple solar modules or panels of the PV system.Microinverters have several advantages over conventional inverters. The main advantage is that small amounts of shading, debris or snow lines on any one solar module, or even a complete module failure, do not disproportionately reduce the output of the entire array. Each microinverter harvests optimum power by performing maximum power point tracking for its connected module. Simplicity in system design, simplified stock management, and added safety are other factors introduced with the microinverter solution.The primary disadvantages of a microinverter include a higher initial equipment cost per peak watt than the equivalent power of a central inverter, and increased installation time since each inverter needs to be installed adjacent to a panel (usually on a roof). This also makes them harder to maintain and more costly to remove and replace (O&M). Some manufacturers have addressed these issues with panels with built-in microinverters.A type of technology similar to a microinverter is a power optimizer which also does panel-level maximum power point tracking, but does not convert to AC per module.