MAX16956 36V, 300mA, Mini Buck Converter with 1.1µA I Q
... available to the undershoot that occurs on a load step, allowing a reduction in the required output capacitance. As the load increases, a small but controlled amount of load regulation (“load-line”) error occurs, so that at heavier loads the voltage is positioned slightly below nominal. This takes a ...
... available to the undershoot that occurs on a load step, allowing a reduction in the required output capacitance. As the load increases, a small but controlled amount of load regulation (“load-line”) error occurs, so that at heavier loads the voltage is positioned slightly below nominal. This takes a ...
PDF:1.14MB
... 1.1 Features of 1200V Mini DIPIPM with BSD Mini DIPIPM with BSD is an ultra-small compact intelligent power module with transfer mold package favorable for larger mass production. Power chips, drive and protection circuits are integrated in the module, which make it easy for AC400-440V class low pow ...
... 1.1 Features of 1200V Mini DIPIPM with BSD Mini DIPIPM with BSD is an ultra-small compact intelligent power module with transfer mold package favorable for larger mass production. Power chips, drive and protection circuits are integrated in the module, which make it easy for AC400-440V class low pow ...
Communication connection for MC784
... This chapter deals with the instructions for measuring instrument connection. Both the use and connection of the device includes handling with dangerous currents and voltages. Connection shall therefore be performed ONLY a by a qualified person using an appropriate equipment. Iskra, d.d. does not ta ...
... This chapter deals with the instructions for measuring instrument connection. Both the use and connection of the device includes handling with dangerous currents and voltages. Connection shall therefore be performed ONLY a by a qualified person using an appropriate equipment. Iskra, d.d. does not ta ...
- Digilent Inc.
... The actual power consumed from the input supply is greater than maximum output power due to the switching regulators not being 100% efficient. The switching regulators used on the NetFPGA-SUME were designed to operate at approximately 90% efficiency. The total power consumed from the input supply ca ...
... The actual power consumed from the input supply is greater than maximum output power due to the switching regulators not being 100% efficient. The switching regulators used on the NetFPGA-SUME were designed to operate at approximately 90% efficiency. The total power consumed from the input supply ca ...
Module - InnoVictor
... solution to combine RF and antenna on the same module. The M10477 is a highly integrated GPS RF Antenna Module suitable for L1-band GPS and A-GPS systems. The device is based on the high performance CSR SiRFstarIV™ GPS architecture combined with Antenova’s high efficiency antenna technology, and is ...
... solution to combine RF and antenna on the same module. The M10477 is a highly integrated GPS RF Antenna Module suitable for L1-band GPS and A-GPS systems. The device is based on the high performance CSR SiRFstarIV™ GPS architecture combined with Antenova’s high efficiency antenna technology, and is ...
Media Center | SMARTEK Vision
... to search for SMARTEK Vision controllers over Ethernet and RS232, all found devices are shown in the list below. Note: There is one of three available flags in front of the Strobe Controller connection displayed in the list of found devices: Device available and waiting for connection Connection to ...
... to search for SMARTEK Vision controllers over Ethernet and RS232, all found devices are shown in the list below. Note: There is one of three available flags in front of the Strobe Controller connection displayed in the list of found devices: Device available and waiting for connection Connection to ...
MAX2023 DS
... Direct conversion architectures are advantageous since they significantly reduce transmitter or receiver cost, part count, and power consumption as compared to traditional IF-based double-conversion systems. In addition to offering excellent linearity and noise performance, the MAX2023 also yields a ...
... Direct conversion architectures are advantageous since they significantly reduce transmitter or receiver cost, part count, and power consumption as compared to traditional IF-based double-conversion systems. In addition to offering excellent linearity and noise performance, the MAX2023 also yields a ...
Stationary Power Distribution Unit (SPDU) 3-phase, 75
... • Basic (p/n PDBMN100) continuously monitors the temperature of the transformer, the status of the main input circuit breaker, and the status of a remote alarm contact. Local audio and visual alarms are initiated when the core temperature of the transformer exceeds maximum parameters. The main input ...
... • Basic (p/n PDBMN100) continuously monitors the temperature of the transformer, the status of the main input circuit breaker, and the status of a remote alarm contact. Local audio and visual alarms are initiated when the core temperature of the transformer exceeds maximum parameters. The main input ...
SKY65326-11 数据资料DataSheet下载
... Customers are responsible for their products and applications using Skyworks products, which may deviate from published specifications as a result of design defects, errors, or operation of products outside of published parameters or design specifications. Customers should include design and operati ...
... Customers are responsible for their products and applications using Skyworks products, which may deviate from published specifications as a result of design defects, errors, or operation of products outside of published parameters or design specifications. Customers should include design and operati ...
CERN/EP/ATE/DQ TTCvx _____________________________________________________________________________________
... Motorola Application Note: Designing with PECL (AN1406) National Application Note: An Overview of LVDS Technology (AN971) ...
... Motorola Application Note: Designing with PECL (AN1406) National Application Note: An Overview of LVDS Technology (AN971) ...
USER MANUAL
... into the external battery socket of the UPS. Do not attempt to connect any loads to the UPS now. You should connect the input power wire to the right position first. And then set the breaker of the battery pack in the “ON” position. After that, set the bypass breaker in the “ON” position. The UPS be ...
... into the external battery socket of the UPS. Do not attempt to connect any loads to the UPS now. You should connect the input power wire to the right position first. And then set the breaker of the battery pack in the “ON” position. After that, set the bypass breaker in the “ON” position. The UPS be ...
Radio-controlled xenon #ashers for atmospheric
... a!ect signi"cantly the fraction of light that propagates from the air shower to the detector. This in turn a!ects both the calculation of the detector aperture and the calculation of shower energy. It is desirable to monitor as much of the actual volume of atmosphere as possible in which the cosmic ...
... a!ect signi"cantly the fraction of light that propagates from the air shower to the detector. This in turn a!ects both the calculation of the detector aperture and the calculation of shower energy. It is desirable to monitor as much of the actual volume of atmosphere as possible in which the cosmic ...
CMOS-tech-loose
... • Parallel read may cause crosstalk or conflict • No overhead maintains maximum full-field frame rate ...
... • Parallel read may cause crosstalk or conflict • No overhead maintains maximum full-field frame rate ...
CMOS-tech-loose-mod - Institute for Astronomy
... • Parallel read may cause crosstalk or conflict • No overhead maintains maximum full-field frame rate ...
... • Parallel read may cause crosstalk or conflict • No overhead maintains maximum full-field frame rate ...
165-260
... recognize the unique waveform characteristics of these selfclearing faults. See Figure 3. By counting how often these events occur over a moving time window, the iTAP-260 is able to give advance notice of pending cable splice failures. This permits cable maintenance to be scheduled rather than addre ...
... recognize the unique waveform characteristics of these selfclearing faults. See Figure 3. By counting how often these events occur over a moving time window, the iTAP-260 is able to give advance notice of pending cable splice failures. This permits cable maintenance to be scheduled rather than addre ...
MAX9796 2.3W, High-Power Class D Audio Subsystem with DirectDrive Headphone Amplifiers General Description
... Lead Temperature (soldering, 10s) .................................+300°C ...
... Lead Temperature (soldering, 10s) .................................+300°C ...
MAX3460–MAX3464 +5V, Fail-Safe, 20Mbps, Profibus RS-485/ RS-422 Transceivers General Description
... rate, and output skew less than 2ns. Each part contains one three-state differential line driver and one differential input line receiver. The devices operate from a +5V supply and feature true fail-safe circuitry, which guarantees a logic-high receiver output when the receiver inputs are open or sh ...
... rate, and output skew less than 2ns. Each part contains one three-state differential line driver and one differential input line receiver. The devices operate from a +5V supply and feature true fail-safe circuitry, which guarantees a logic-high receiver output when the receiver inputs are open or sh ...
Solar micro-inverter
A solar micro-inverter, or simply microinverter, is a device used in photovoltaics that converts direct current (DC) generated by a single solar module to alternating current (AC). The output from several microinverters is combined and often fed to the electrical grid. Microinverters contrast with conventional string and central solar inverters, which are connected to multiple solar modules or panels of the PV system.Microinverters have several advantages over conventional inverters. The main advantage is that small amounts of shading, debris or snow lines on any one solar module, or even a complete module failure, do not disproportionately reduce the output of the entire array. Each microinverter harvests optimum power by performing maximum power point tracking for its connected module. Simplicity in system design, simplified stock management, and added safety are other factors introduced with the microinverter solution.The primary disadvantages of a microinverter include a higher initial equipment cost per peak watt than the equivalent power of a central inverter, and increased installation time since each inverter needs to be installed adjacent to a panel (usually on a roof). This also makes them harder to maintain and more costly to remove and replace (O&M). Some manufacturers have addressed these issues with panels with built-in microinverters.A type of technology similar to a microinverter is a power optimizer which also does panel-level maximum power point tracking, but does not convert to AC per module.