• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
AutomationNotebook Issue 5
AutomationNotebook Issue 5

... swappable for uninterrupted maintenance and can be loaded up to 15A each. For configuring a DC UPS, the Battery Controller Module provides a battery management system for charging and monitoring a lead-acid battery. The Battery Controller module also has an option for connecting an external temperat ...
DM32711716
DM32711716

... operation. In electric locomotives, the motor may run clock wise and anti clockwise, and the torque may act either with or against the direction of rotation. In other words the speed and torque may be positive or negative. An attempt is made in this paper to demonstrate this principle by designing t ...
Colonne lumineuse
Colonne lumineuse

L03-CMOS-Gates
L03-CMOS-Gates

Implementation of Efficiency Enhancement Techniques in the Linear
Implementation of Efficiency Enhancement Techniques in the Linear

... It is well known that power amplifiers cannot operate efficiently when used for linear amplification. The classes A, B and AB are considered linear amplifiers and have been used for linear applications such examples are amplitude modulation (AM), single-sideband modulation (SSB), and quadrate amplit ...
PDF
PDF

... The four terminals of a fet (gate, source, drain and bulk) connect to conducting surfaces that generate a complicated set of electric fields in the channel region which depend on the relative voltages of each terminal. gate Surface of wafer ...
23.1 0.45-V Input On-Chip Gate Boosted (OGB) Buck Converter in
23.1 0.45-V Input On-Chip Gate Boosted (OGB) Buck Converter in

... the die-to-die delay variations of a delay line in the PWM controller with good controllability is also proposed. Introduction Adaptive power supply voltage (VDD) control is important for near-threshold logic circuits to achieve an energy efficient operation against PVT variations, because low VDD c ...
INSTALLATION INSTRUCTIONS MODEL PA1235X 12 CHANNEL POWER AMPLIFIER
INSTALLATION INSTRUCTIONS MODEL PA1235X 12 CHANNEL POWER AMPLIFIER

... Wall or Ceiling Mounting – The appliance should be mounted to a wall or ceiling only as recommended by the manufacturer. Ventilation – The appliance should be situated so that its location or position does not interfere with its proper ventilation. For example, the appliance should not be situated o ...
ADN8810 12-Bit High Output Current Source (Rev. A) Data Sheet
ADN8810 12-Bit High Output Current Source (Rev. A) Data Sheet

... may cause permanent damage to the device. This is a stress rating only; functional operation of the device at these or any other conditions above those indicated in the operational section of this specification is not implied. Exposure to absolute maximum rating conditions for extended periods may a ...
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE)
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE)

... information technology. Power- system design for these applications has long been dominated by such issues as efficiency, thermal management, voltage regulation, reliability, power density, and cost. Going forward, these factors will remain critical. A typical breakdown of electricity use and power ...
File lm4780 | allcomponents.ru
File lm4780 | allcomponents.ru

Progress in On-Line Measurement of PD in G.C. Stone I. Culbert
Progress in On-Line Measurement of PD in G.C. Stone I. Culbert

... becoming more popular for energy conservation and the reduction in inrush currents. The type of drive that is becoming more popular today employs a voltage-source, pulse width modulated (VS-PWM) inverter, since it tends to be more economical than other possible topologies. Unfortunately, such invert ...
to this file: /unr15-25w
to this file: /unr15-25w

Offers High-speed Input Response of 0.1 ms and Equipped with
Offers High-speed Input Response of 0.1 ms and Equipped with

... AND: The output is turned ON when IN1 and IN2 input signals are both ON. OR: The output is turned ON when either IN1 or IN2 input signal is ON. : The output is turned ON while both IN1 and IN2 input signals are ON. : If the input signal of IN2 is turned ON (at the rising edge) while the IN1 input si ...
Model HU-224/225 - Building Controls Connection Inc
Model HU-224/225 - Building Controls Connection Inc

... 1. Remove the blue terminal block by carefully pulling it off the circuit board. 2. Locate the [+] and [-] terminal markings on the board. 3. Attach the supply voltage to the [+] lead. 4. Connect the 4-20 mA output ([-] terminal) to the controller’s input terminal. 5. Ensure that the power supply co ...
Evaluates:  MAX1534 MAX1534 Evaluation Kit General Description Features
Evaluates: MAX1534 MAX1534 Evaluation Kit General Description Features

... The MAX1534 evaluation kit (EV kit) is a fully assembled and tested surface-mount circuit board that demonstrates the MAX1534 triple-output keep-alive power supply IC. The MAX1534 integrates one high-performance step-down converter and two low-dropout regulators (LDOs). The step-down converter is co ...
FS-TRI-S - Fire Alarm Resources
FS-TRI-S - Fire Alarm Resources

... All power limited wiring must enter the electrical box separately from the electric light, power, Class 1, or non-powered limited fire protection signaling conductors. For the FS-TRI-R, wiring to terminal block positions 1, 2, 3, 4, and 5 must enter the outlet box separately from terminals 6, 7, and ...
LM140K Series 3-Terminal Positive Regulators
LM140K Series 3-Terminal Positive Regulators

... Texas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, enhancements, improvements and other changes to its semiconductor products and services per JESD46, latest issue, and to discontinue any product or service per JESD48, latest issue. Buyers should obtain t ...
IOSR Journal of Electronics & Communication Engineering (IOSR-JECE)
IOSR Journal of Electronics & Communication Engineering (IOSR-JECE)

... performance p-q theory is much faster than compensation using SDM. In [16] it is proved that p-q theory compensates the undesirable current components within 1st cycle whereas SDM takes about 14 cycles (approximately 0:23 seconds for 50 Hz source). So for faster power quality improvement SDM is not ...
Active inductor-based tunable impedance matching network for RF
Active inductor-based tunable impedance matching network for RF

... matching network can decrease this reflection, maximizes the transferred power to the load, and also minimizes the returns from the load. The impedance matching occurs at a certain frequency (especially at the resonance frequency) and causes that the maximum power is transferred between the supply an ...
DeltaV™ Bulk Power Supplies
DeltaV™ Bulk Power Supplies

Symmetra PX Guide Specifications
Symmetra PX Guide Specifications

... or less at full system, while providing conditioned power to the critical load bus, and charging the batteries under steady-state operating conditions. This shall be true while supporting loads of both a linear or non-linear type. This shall be accomplished with no additional filters, magnetic devic ...
FEATURES FUNCTIONAL BLOCK DIAGRAM
FEATURES FUNCTIONAL BLOCK DIAGRAM

... may cause permanent damage to the device. This is a stress rating only; functional operation of the device at these or any other conditions above those indicated in the operational section of this specification is not implied. Exposure to absolute maximum rating conditions for extended periods may a ...
Evaluates: MAX1778/MAX1880/MAX1881/MAX1882 MAX1778 Evaluation Kit General Description Features
Evaluates: MAX1778/MAX1880/MAX1881/MAX1882 MAX1778 Evaluation Kit General Description Features

... configured for a +8V output that provides up to 250mA of current from a +3.0V supply. The EV kit can be powered from a +2.7V to +5.5V supply. The positive charge-pump circuit is configured for a +20V output that provides more than 10mA of current. The negative charge-pump circuit is configured for a ...
2.1 Introduction - Fred. Olsen Energy
2.1 Introduction - Fred. Olsen Energy

< 1 ... 122 123 124 125 126 127 128 129 130 ... 384 >

Solar micro-inverter



A solar micro-inverter, or simply microinverter, is a device used in photovoltaics that converts direct current (DC) generated by a single solar module to alternating current (AC). The output from several microinverters is combined and often fed to the electrical grid. Microinverters contrast with conventional string and central solar inverters, which are connected to multiple solar modules or panels of the PV system.Microinverters have several advantages over conventional inverters. The main advantage is that small amounts of shading, debris or snow lines on any one solar module, or even a complete module failure, do not disproportionately reduce the output of the entire array. Each microinverter harvests optimum power by performing maximum power point tracking for its connected module. Simplicity in system design, simplified stock management, and added safety are other factors introduced with the microinverter solution.The primary disadvantages of a microinverter include a higher initial equipment cost per peak watt than the equivalent power of a central inverter, and increased installation time since each inverter needs to be installed adjacent to a panel (usually on a roof). This also makes them harder to maintain and more costly to remove and replace (O&M). Some manufacturers have addressed these issues with panels with built-in microinverters.A type of technology similar to a microinverter is a power optimizer which also does panel-level maximum power point tracking, but does not convert to AC per module.