• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Old Company Name in Catalogs and Other Documents
Old Company Name in Catalogs and Other Documents

... “High Quality”: Transportation equipment (automobiles, trains, ships, etc.); traffic control systems; anti-disaster systems; anticrime systems; safety equipment; and medical equipment not specifically designed for life support. “Specific”: Aircraft; aerospace equipment; submersible repeaters; nuclea ...
Load range extension methods for lightning impulse testing with
Load range extension methods for lightning impulse testing with

... range of a lightning impulse test circuit. The front time T1 of a lightning impulse is proportional to the product of the total front resistance RS and the series connection of the test capacitance and the impulse generator capacitance. High capacitive test objects require a low series resistance va ...
Circuit Breaker
Circuit Breaker

MAX13330/MAX13331 Automotive DirectDrive Headphone Amplifiers with Output Protection and Diagnostics General Description
MAX13330/MAX13331 Automotive DirectDrive Headphone Amplifiers with Output Protection and Diagnostics General Description

... ±15kV Human Body Model ESD protection and shortcircuit protection up to +45V at the headphone outputs. Comprehensive click-and-pop circuitry suppresses audible clicks and pops on startup and shutdown. A low-power shutdown mode reduces the supply current to 3µA (typ). The MAX13330/MAX13331 are specif ...
P83884
P83884

... locating Notification Appliance Circuits (NAC) and notification appliances. Some system communication circuits and/or audio circuits, for example, may require special precautions to assure electrical noise immunity (e.g. audio crosstalk). NOTE: This equipment has been tested and found to comply with ...
ledflatlight - Pixi Lighting
ledflatlight - Pixi Lighting

... on the Mounting Plate (A), being careful not to bend the hooks; slide to lock. ...
Y. Hu, L. Huang, W. Rieutort-Louis, J. Sanz-Robinson, J.C. Sturm, S. Wagner, N. Verma, "A Self-Powered System for Large-Scale Strain Sensing by Combining CMOS ICs with Large-Area Electronics", J. Solid-State Circuits, Vol 49, pp. 838-840 (APR 2014).
Y. Hu, L. Huang, W. Rieutort-Louis, J. Sanz-Robinson, J.C. Sturm, S. Wagner, N. Verma, "A Self-Powered System for Large-Scale Strain Sensing by Combining CMOS ICs with Large-Area Electronics", J. Solid-State Circuits, Vol 49, pp. 838-840 (APR 2014).

... with typical values [10]). Adequate power for full-system operation is thus easily provided. For DC-AC power conversion, however, the TFTs pose substantial challenges due to their low currents. This implies increased conduction and switching losses, potentially degrading efficiency, as well as low p ...
BD6968FVM
BD6968FVM

... It is possible that the motor output terminal may deflect below GND terminal because of influence by back electromotive force of motor. The potential of GND terminal must be minimum potential in all operating conditions, except that the levels of the motor outputs terminals are under GND level by th ...
Bi-directional level shifter for I²C-bus and other systems.
Bi-directional level shifter for I²C-bus and other systems.

... If VDD2 is switched-off then T3 and T4 becomes not conducting and the “Higher voltage” section is isolated from the other part of the bus system. The pull-up resistors Rp to VDD3 are not necessary for the proper operation and may have a high resistance value, they can be added to prevent the MOS-FET ...
REO current and voltage sensors
REO current and voltage sensors

IEEE 802.3at PoE High-Power PD Interface with External Gate Driver
IEEE 802.3at PoE High-Power PD Interface with External Gate Driver

... should equal 24.9 kΩ. If the resistance connected between VDD and DEN is divided into two roughly equal portions, then the application circuit can disable the PD by grounding the tap point between the two resistances. This action simultaneously spoils the detection signature and thereby signals the ...
loudspeaker impedance with sia smaartlive
loudspeaker impedance with sia smaartlive

... capability of conventional computer sound cards, and the power handling capability of the shunt resistor becomes increasingly important as more current is drawn into the load. When using a power amplifier, the output voltage must be limited to a safe level and power resistors used in designing the c ...
BD6967FVM
BD6967FVM

... It is possible that the motor output terminal may deflect below GND terminal because of influence by back electromotive force of motor. The potential of GND terminal must be minimum potential in all operating conditions, except that the levels of the motor outputs terminals are under GND level by th ...
Liebert RDC™ Remote Distribution Cabinet
Liebert RDC™ Remote Distribution Cabinet

... Verify that all incoming line voltage (power) circuits are de-energized and locked out before installing cables or making connections, whether in the junction box or in the unit. ...
TM-35XJC, TM-35XJF, TM-35XKC & TM-35XKF Panel Temperature Meters 3 1/2 Digit 0.48” LCD
TM-35XJC, TM-35XJF, TM-35XKC & TM-35XKF Panel Temperature Meters 3 1/2 Digit 0.48” LCD

... The differential input feature of the TM-35X facilitates temperature measurement using grounded thermocouples. In this configuration, an indirect ground return path is still required to prevent the common mode range of the inputs from being exceeded, but the circuit differs from the single-ended con ...
APPLICATION NOTE AN/96031 TDA8790M EVALUATION BOARD DOCUMENTATION
APPLICATION NOTE AN/96031 TDA8790M EVALUATION BOARD DOCUMENTATION

Wire Connectors - Mike Holt`s Forum
Wire Connectors - Mike Holt`s Forum

Application Guidelines for Ground Fault Protection
Application Guidelines for Ground Fault Protection

... A ground relay must detect all phase-to-ground faults within its defined zone of protection under conditions which produce minimum fault current. The ground relay zone of protection can be defined as a current threshold or measured impedance. The classical method for detecting ground faults on a lo ...
Article 690 - Solar Photovoltaic (PV) Systems
Article 690 - Solar Photovoltaic (PV) Systems

... (E) Bipolar Source and Output Circuits. For 2-wire circuits connected to bipolar systems, the maximum system voltage shall be the highest voltage between the conductors of the 2-wire circuit if all of the following conditions apply: (1) One conductor of each circuit of a bipolar subarray is solidly ...
Electrical Transformers, Generators and Protection Theory
Electrical Transformers, Generators and Protection Theory

... Current (as the name implies) is the movement or flow of electrons (I) and is measured in units of Amperes. This is usually abbreviated to Amp or, even shorter, A. The flow of electrons in an electrical current can be considered the same as the flow of water molecules in a stream. To get anything to ...
Datasheet
Datasheet

... MAGMA can operate with input voltages from 6 to 30V. It also features an internal voltage reference, input feed forward compensation making it less sensitive to input voltage variations, and a soft start activated whenever MAGMA comes out of stand-by or the output is enabled. ...
BD3512MUV
BD3512MUV

... insufficient total phase compensation, thus causing oscillation. In light of this information, please confirm operation across a variety of temperature and load conditions. Input capacitors reduce the output impedance of the voltage supply source connected to the (VCC) input pins. If the impedance o ...
Transformerless UPS systems and the 9900
Transformerless UPS systems and the 9900

... There is a growing trend in the UPS industry to create a highly efficient, more lightweight and smaller UPS system. Data Centers across the world are constantly searching for new ways to maximize reliable UPS power while minimizing the UPS and associated equipment footprint. In addition, operating c ...
Datasheet
Datasheet

... II 1 D Ex ia IIIC T100 °C Da IP6X. • The IECEx markings for gas and dust applications are: Ex ia IIC/IIB T4 Ga and Ex ia IIIC T100 °C Da IP6X. It is allowed to connect up to six barriers in IIB/IIIC applications or one barrier in IIC applications. Consult the certificate for the maximum input and ou ...
PowerLogic™ DM6000 Series Digital Meters Quick Start Guide
PowerLogic™ DM6000 Series Digital Meters Quick Start Guide

... Turn off all power supplying the digital meter and the equipment in which it is installed before working on it. Always use a properly rated voltage sensing device to confirm that all power is off. Before closing all covers and doors, inspect the work area for tools and objects that may have been lef ...
< 1 ... 84 85 86 87 88 89 90 91 92 ... 584 >

Ground (electricity)



In electrical engineering, ground or earth is the reference point in an electrical circuit from which voltages are measured, a common return path for electric current, or a direct physical connection to the Earth.Electrical circuits may be connected to ground (earth) for several reasons. In mains powered equipment, exposed metal parts are connected to ground to prevent user contact with dangerous voltage if electrical insulation fails. Connections to ground limit the build-up of static electricity when handling flammable products or electrostatic-sensitive devices. In some telegraph and power transmission circuits, the earth itself can be used as one conductor of the circuit, saving the cost of installing a separate return conductor (see single-wire earth return).For measurement purposes, the Earth serves as a (reasonably) constant potential reference against which other potentials can be measured. An electrical ground system should have an appropriate current-carrying capability to serve as an adequate zero-voltage reference level. In electronic circuit theory, a ""ground"" is usually idealized as an infinite source or sink for charge, which can absorb an unlimited amount of current without changing its potential. Where a real ground connection has a significant resistance, the approximation of zero potential is no longer valid. Stray voltages or earth potential rise effects will occur, which may create noise in signals or if large enough will produce an electric shock hazard.The use of the term ground (or earth) is so common in electrical and electronics applications that circuits in portable electronic devices such as cell phones and media players as well as circuits in vehicles may be spoken of as having a ""ground"" connection without any actual connection to the Earth, despite ""common"" being a more appropriate term for such a connection. This is usually a large conductor attached to one side of the power supply (such as the ""ground plane"" on a printed circuit board) which serves as the common return path for current from many different components in the circuit.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report