• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
SP207E 数据资料DataSheet下载
SP207E 数据资料DataSheet下载

... The SP207E-SP213E are enhanced transceivers intended for use in RS-232 and V.28 serial communication. These devices feature very low power consumption and single-supply operation making them ideal for space-constrained applications. Exar-patented (5,306,954) on-board charge pump circuitry generates ...
The Fluorescent Lamp Circuit - Circuits and Systems I: Fundamental
The Fluorescent Lamp Circuit - Circuits and Systems I: Fundamental

mic2592b.pdf
mic2592b.pdf

... Interconnect Express (PCI Express) Hot-Plug compliant systems. The MIC2592B provides complete power control support for two PCI Express slots, including the 3.3VAUX defined by the PCI Express standards. Support for 12V, 3.3V, and 3.3VAUX supplies is provided including programmable constant-current i ...
Gas-insulated switchgear type series 8DN8
Gas-insulated switchgear type series 8DN8

... pressure-resistant, gas-tight enclosures. With a remarkably small number of active and passive modules, all customary bus schemes are possible. Adapter solutions ensure compatibility with all predecessor models of the same voltage level. Three-phase enclosures are used for type series 8DN8 switchgea ...
Fuses – Introductory Information
Fuses – Introductory Information

... The most important point of a fuse specification is the time/current characteristic. This curve describes the breaking behaviour of fuses in the overload range which usually covers currents from 1 x IN or 1,5 x IN (depending on type and style) up to approximately 3 x IN. Above these currents, the sh ...
Advanced Cascade Multilevel Converter with Reduction in Number
Advanced Cascade Multilevel Converter with Reduction in Number

ALM2402-Q1 Dual Op-amp with High Current Output
ALM2402-Q1 Dual Op-amp with High Current Output

Sollatek SVS Range Voltage Stabilisers
Sollatek SVS Range Voltage Stabilisers

... • FOLLOW all safety instructions and use caution when installing and operating any electrical equipment. • CHECK that the voltage of the mains electricity supply is the same as the voltage of the SVS (see label on back) BEFORE connecting the SVS to the electricity supply. • CHECK that the maximum cu ...
4N25 - Vishay
4N25 - Vishay

... Vishay Intertechnology, Inc., its affiliates, agents, and employees, and all persons acting on its or their behalf (collectively, “Vishay”), disclaim any and all liability for any errors, inaccuracies or incompleteness contained in any datasheet or in any other disclosure relating to any product. Vi ...
JP2216191626
JP2216191626

... selection of the switching states for the voltage vectors is here to simultaneously eliminate the common mode voltage and to eliminate the DC-link capacitor voltage unbalancing. For the elimination of the CMV, only those switching states that have the zero CMV are switched for the PWM operation, (Ta ...
Antenna Detection Application Note
Antenna Detection Application Note

... Two slightly different hardware solutions are here presented: the first one is suitable to be used in conjunction with the antenna detection AT command, i.e. AT#GSMAD, thus simplifying application firmware. The second solution gives a higher flexibility degree to system integrator, permitting a bett ...
chapter2_circuit_breakers_jan_2014
chapter2_circuit_breakers_jan_2014

... ionized particles tries to maintain the current when contacts are separated.This flow of charged particles form one contact to other is called an arc . The medium surrounding the arc also contains ions . Due to this charged particles the arc continues even if the breakers contacts are separated. The ...
Note 2
Note 2

... The LTC1149 series uses a constant off-time architecture with tOFF determined by an external timing capacitor CT. Each time the P-channel MOSFET switch turns on, the voltage on CT is reset to approximately 3.3V. During the off-time, CT is discharged by a current which is proportional to VOUT. The vo ...
TE News_11_10.qxd:GAN 09_05_final.qxd
TE News_11_10.qxd:GAN 09_05_final.qxd

... the most common HV applications. The first category, up to 40 A, is for conductor cross-sections of 2.5 ... 6 mm2. In the second category, currents of up to 250 A are defined for cable cross-sections ranging from 16 … 50 mm2. These parameters were intentionally selected to avoid too great a diversit ...
ST2200 Soldering Iron Tester Instruction Manual
ST2200 Soldering Iron Tester Instruction Manual

... when applied to the sensor. All measurements are made with respect to the Earth Ground pin of the AC line plug. The FAIL MV/OHM warning indicator (3) will flash red for any reading of 2.00 mV and above while the actual mV value is shown by the digital display. The units range is 0.00 to 30.00 mV Tru ...
AN2690
AN2690

... The PFC controller is the L6563 (U1), working in transition mode. It integrates all functions needed to control the PFC and interface the master converter. Its power stage topology is a conventional boost converter, connected to the output of the mains rectifier bridge. It includes the coil L2, the ...
High Voltage Engineering
High Voltage Engineering

Design Methodology for Transformers Including Integrated
Design Methodology for Transformers Including Integrated

Installation Manual
Installation Manual

... factory door lock control relay. The green wire provides the first ground pulse during disarming, or the drivers door pulsed ground unlock output. Connect this wire to the drivers door unlock relay that requires a low current ground signal to unlock only the drivers door. If the vehicle does not hav ...
PRODUCT HANDBOOK
PRODUCT HANDBOOK

... mount units designed to protect sensitive PLCs and process equipment; plug in units for final circuit outlets; to 2000A per phase filters designed to protect major data centres. Surge ratings up to 250kA (8/20µs) are available making surge filters suitable for providing primary and secondary protect ...
BD2200GUL, BD2201GUL
BD2200GUL, BD2201GUL

... lines of the digital and analog blocks to prevent noise in the ground and supply lines of the digital block from affecting the analog block. Furthermore, connect a capacitor to ground at all power supply pins. Consider the effect of temperature and aging on the capacitance value when using electroly ...
Earth Faults in Extensive Cable Networks
Earth Faults in Extensive Cable Networks

RRR040P03
RRR040P03

... The content specified herein is subject to change for improvement without notice. The content specified herein is for the purpose of introducing ROHM's products (hereinafter "Products"). If you wish to use any such Product, please be sure to refer to the specifications, which can be obtained from RO ...
MC33812, Multifunctional Ignition and Injector Driver
MC33812, Multifunctional Ignition and Injector Driver

S280-79-10
S280-79-10

... at time of order entry. Primary power is rectified to charge the power capacitor and to power the dc/dc converter that provides power to the control. A minimum of 500 mA of ac current is required for heater operation, battery charging current, and to keep all modules energized. ...
< 1 ... 57 58 59 60 61 62 63 64 65 ... 584 >

Ground (electricity)



In electrical engineering, ground or earth is the reference point in an electrical circuit from which voltages are measured, a common return path for electric current, or a direct physical connection to the Earth.Electrical circuits may be connected to ground (earth) for several reasons. In mains powered equipment, exposed metal parts are connected to ground to prevent user contact with dangerous voltage if electrical insulation fails. Connections to ground limit the build-up of static electricity when handling flammable products or electrostatic-sensitive devices. In some telegraph and power transmission circuits, the earth itself can be used as one conductor of the circuit, saving the cost of installing a separate return conductor (see single-wire earth return).For measurement purposes, the Earth serves as a (reasonably) constant potential reference against which other potentials can be measured. An electrical ground system should have an appropriate current-carrying capability to serve as an adequate zero-voltage reference level. In electronic circuit theory, a ""ground"" is usually idealized as an infinite source or sink for charge, which can absorb an unlimited amount of current without changing its potential. Where a real ground connection has a significant resistance, the approximation of zero potential is no longer valid. Stray voltages or earth potential rise effects will occur, which may create noise in signals or if large enough will produce an electric shock hazard.The use of the term ground (or earth) is so common in electrical and electronics applications that circuits in portable electronic devices such as cell phones and media players as well as circuits in vehicles may be spoken of as having a ""ground"" connection without any actual connection to the Earth, despite ""common"" being a more appropriate term for such a connection. This is usually a large conductor attached to one side of the power supply (such as the ""ground plane"" on a printed circuit board) which serves as the common return path for current from many different components in the circuit.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report