• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Twenty Questions - Kelso High School
Twenty Questions - Kelso High School

... decreased as the current has increased. • I=V/R, where V is constant. ...
Sink vs Source
Sink vs Source

... Voltage Drop: The loss of voltage between the input to a device and the output from a device due to the internal impedance or resistance of the device. In all electrical systems, the conductors should be sized so that the voltage drop never exceeds 3% for power, heating, and lighting loads or combin ...
ULTRA SLIMPAK II WV905 ®
ULTRA SLIMPAK II WV905 ®

... instruments, including Action's Ultra SlimPak II, Ultra SlimPak, and ActionI/Q models. The WV905 will operate on input voltages ranging from 85 to 265VAC or 120 to 300VDC. The 24VDC, 0.5A output has overcurrent shutdown with automatic restart and thermal shutdown. The input is proteccted by fuse, a ...
Earth System – Current Injection Testing (CIT) Services
Earth System – Current Injection Testing (CIT) Services

... equipment to accurately measure earth grid impedance, step, touch and transfer voltages, earth potential rise (EPR)  contours, current splits in overhead earth wires and underground cable screens, and electrical continuity of earthed  structures  in  high  voltage  substations,  switch‐yards  and  p ...
1E6_Tutorial 8
1E6_Tutorial 8

... Explain the meaning of the term resonance as applied to a series a.c. circuit. Draw the phasor diagram to illustrate this condition A series circuit consists of 0.5 F capacitor, a coil of inductance 0.32 H and a resistance of 40 , and a 20  non-inductive resistor. Calculate the value of the reson ...
Document
Document

... system through the isolation transformer is controlled. No chance of a lifted neutral wire from the transformer (unless tampered with). ...
Guidelines for Providing Surge Protection Introduction
Guidelines for Providing Surge Protection Introduction

... with a robust surge protection system. An electrical transient is a short duration, high energy impulse that is imparted on the normal electrical power system whenever there is a sudden change in the electrical circuit. They can originate from a variety of sources, both internal and external to a fa ...
File
File

... Battery pack - the pack can lack the aligator clips. If you donot have them, wrap the foil around the bare wire. you can find the parts to make this at Radio Shack - You moight have to let them know in advance to have enought battery packs to do this with a class. Do not use a 9 volt battery. they g ...
LEF AC Power Surge prevention
LEF AC Power Surge prevention

... Lightning overvoltage is caused by a strike of lightning to or near a conductor or shield of an intercom cable. Shielded wire does not provide complete protection against lightning damage. When lightning or other voltage spikes flow on the shield of a cable, voltage is induced between the internal c ...
Blue Laser Diode NDB7875
Blue Laser Diode NDB7875

... ACC(Auto Current Control) mode is recommended for the Product operation. Also, please be careful for the overshooting in order to avoid excessive optical output power as the laser operation is started. (2) Static Electricity Static electricity or electrical surges will reduce and degrade the reliabi ...
Circuits #3 - Electro Tech Online
Circuits #3 - Electro Tech Online

... Electricity and magnetism will affect each other. The flow of current affects magnetic fields, and magnetic fields affect current flow ...
Mr. Sarver Review Questions 16 The current will flow only as long as
Mr. Sarver Review Questions 16 The current will flow only as long as

... 2. Taking the 220V machine and hardwiring to the 110V circuit. At first glance I don’t know how you would do it practically. • Suppose you secure one of the hot wires from the 220V machine and the neutral and ground (if they are both there) to the neutral and ground of the 110V circuit. Then when th ...
Wiring recepticals
Wiring recepticals

AV100-750 - Europower Components Ltd
AV100-750 - Europower Components Ltd

... For the electronic measurement of voltages : DC, AC, pulsed..., with a galvanic isolation between the primary circuit (high voltage) and the secondary circuit (electronic circuit). ...
Chapter 11
Chapter 11

... A unit of measurement for electrical current One volt across a resistance of one ohm will produce a flow of one amp ...
Physics 517/617 Experiment 3 Diodes
Physics 517/617 Experiment 3 Diodes

... input resistor. Derive the 5 Volt reference from a 5 Volt source (power supply). Apply a 1 kHz sine wave. Vary the amplitude of the input voltage and capture using the PC's WAVESTAR program pictures of the input and output waveforms (2 waveforms/picture). Repeat for a triangular input waveform. 3) B ...
Measuring Ground Resistance — The Fall of Potential Method
Measuring Ground Resistance — The Fall of Potential Method

... accurately measured, the test set simply uses Ohm’s law to calculate and display the resistance. Simple, right? Yes, from the standpoint of theory of operation, it is. To avoid polarization effects, the test sets commonly employ an alternating square wave current. IEEE suggests this be at or near po ...
Photovoltaic Protection (Solar Systems)
Photovoltaic Protection (Solar Systems)

... independent of any other electrical power source. Interactive systems operate in parallel with another electrical power source such as being connected to an electrical utility system. An interactive system may also supply electric power to the production or distribution network. Hybrid systems inclu ...
Coaxial Cable Protection
Coaxial Cable Protection

... signal, according to its frequency. This effect is present in coax cable, keeping the RF signal inside and any coupled outside interference on the shield’s outer surface. The effect begins to fall apart as the frequency is lowered and the penetration, which is a gradient, begins to mix the shield’s ...
1395 Connection Guide - Allen
1395 Connection Guide - Allen

IOD40 Instructions for Ion, Electric Field, Lightning and Paranormal
IOD40 Instructions for Ion, Electric Field, Lightning and Paranormal

... It is important to remember that any type of leakage around the input of Q1 can reduce the sensitivity. The input to the unit must be switched by low leakage slider switches. The particular ones used have 5 to 10 gohm resistance. Unfortunately they will reduce performance in high humidity environmen ...
Test1_Spring12 - UTK-EECS
Test1_Spring12 - UTK-EECS

... and it is terminated in a load with impedance ZL = (200j200) . Find the following: (a) Reflection coefficient  at the load, (b) Input impedance Zin at the input end of the transmission line, (c) The input voltage vi(t) and input current ii(t), [Hint: simple circuit. First use phasors, then get to ...
Project Specification - ECE Senior Design
Project Specification - ECE Senior Design

Transformer Turn Ratio IRT-101
Transformer Turn Ratio IRT-101

FUNDAMENTALS OF WATER
FUNDAMENTALS OF WATER

... When the loop is parallel to the magnetic lines of force, no magnetic flux is interrupted and no EMF is induced to the loop. As it begins to rotate, it cuts the magnetic flux at an increasing rate reaching a maximum when it has rotated a quarter turn (i.e. 90°). As the rotation continues, the EMF is ...
< 1 ... 548 549 550 551 552 553 554 555 556 ... 584 >

Ground (electricity)



In electrical engineering, ground or earth is the reference point in an electrical circuit from which voltages are measured, a common return path for electric current, or a direct physical connection to the Earth.Electrical circuits may be connected to ground (earth) for several reasons. In mains powered equipment, exposed metal parts are connected to ground to prevent user contact with dangerous voltage if electrical insulation fails. Connections to ground limit the build-up of static electricity when handling flammable products or electrostatic-sensitive devices. In some telegraph and power transmission circuits, the earth itself can be used as one conductor of the circuit, saving the cost of installing a separate return conductor (see single-wire earth return).For measurement purposes, the Earth serves as a (reasonably) constant potential reference against which other potentials can be measured. An electrical ground system should have an appropriate current-carrying capability to serve as an adequate zero-voltage reference level. In electronic circuit theory, a ""ground"" is usually idealized as an infinite source or sink for charge, which can absorb an unlimited amount of current without changing its potential. Where a real ground connection has a significant resistance, the approximation of zero potential is no longer valid. Stray voltages or earth potential rise effects will occur, which may create noise in signals or if large enough will produce an electric shock hazard.The use of the term ground (or earth) is so common in electrical and electronics applications that circuits in portable electronic devices such as cell phones and media players as well as circuits in vehicles may be spoken of as having a ""ground"" connection without any actual connection to the Earth, despite ""common"" being a more appropriate term for such a connection. This is usually a large conductor attached to one side of the power supply (such as the ""ground plane"" on a printed circuit board) which serves as the common return path for current from many different components in the circuit.