• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Abstract - PG Embedded systems
Abstract - PG Embedded systems

... achieved by light being generated on one side of a transparent insulating gap and being detected on the other side of the gap without an electrical connection between the two sides (except for a minor amount of coupling capacitance). ...
High-Current, Rail-Mounted Terminal Blocks 50 mm² to 185
High-Current, Rail-Mounted Terminal Blocks 50 mm² to 185

... Caution! Power is still on even after switching off the main switch! ...
29477 Demonstrate knowledge of the New Zealand national
29477 Demonstrate knowledge of the New Zealand national

Problems 2 - MyCourses
Problems 2 - MyCourses

The standard for quality with highest voltages. BAUR`s high voltage
The standard for quality with highest voltages. BAUR`s high voltage

Experiment 1-2
Experiment 1-2

Model STA-3108D1 Packing List
Model STA-3108D1 Packing List

... test. ALWAYS remove power from the entire test system and discharge any capacitors before: connecting or disconnecting cables or jumpers, installing or removing switching cards, or making internal changes, such as installing or removing jumpers. Do not touch any object that could provide a current p ...
Hazards and Risks when working with Electricity
Hazards and Risks when working with Electricity

... curable burn threshold,’ is skin temperature raised to 175oF for 0.1 second.  A third degree burn threshold, or ‘incurable burn threshold,’ is skin temperature raised to 200oF for 0.1 second.  Eardrum damage > 720 psf  Lung damage > 1728 psf ...
EVS-03-04 Comments on Protective Barrier Option for Post
EVS-03-04 Comments on Protective Barrier Option for Post

... not pursuaded that a low-energy option of 0.2 Joules is adequate for ensuring electrical safety. We are reiterating our position of the energy option for electrical safety as outlined in the June 2012 final rule. The agency conducted its own analysis using Figures 20 and 22 of IEC TS 60479–1(Figures ...
Mains Frequency to Current/ Voltage Converter E1 - Lee
Mains Frequency to Current/ Voltage Converter E1 - Lee

Shielded Metal Arc Welding (SMAW)
Shielded Metal Arc Welding (SMAW)

... – Jacket, Coveralls, gloves ...
What Is Rectification? What Is Smoothing?
What Is Rectification? What Is Smoothing?

... Rectification is the conversion of alternating current to direct current. Rectification is performed by a diode that allows current to flow in one direction but not in the opposite direction. Direct current that has only been rectified, however, has various changes in voltage ( ripples ) lingering f ...
Revision 15 Static and 16 Current Electricity
Revision 15 Static and 16 Current Electricity

... charged body. • Gold Leaf electroscope is a special kind of electroscope that can detect very feeble charges. If the body is uncharged, the gold leaves show no movement of divergence, and the body being tested, is said to be neutral. If there is a charge, the leaves diverge. For positive charge the ...
Untitled
Untitled

N1000 Autotransformer
N1000 Autotransformer

... distortion, lowers transformer losses, frees up transformer and feeder capacity and reduces phase current imbalance. It is ideally suited to all applications where existing equipment fails to treat 3rd harmonic current and voltage distortion. DESCRIPTION AND CHARACTERISTICS ...
TT11 Circuit Breakers Name How Circuit Breakers Work by Tom
TT11 Circuit Breakers Name How Circuit Breakers Work by Tom

... example, has a filament inside that is very resistant to flowing charge. The charge has to work hard to move along, which heats up the filament, causing it to glow. In building wiring, the hot wire and the neutral wire never touch directly. The charge running through the circuit always passes throug ...
Micro Controller Power Circuitry
Micro Controller Power Circuitry

... In many applications it is required to have complete voltage and therefore current control without the ability to vary the input voltage. In many instances a system will require a multitude of output voltages for varying devices with only one input voltage. For this case a technique called Pulse Wid ...
EVO 160-200
EVO 160-200

... Thermal overload protec on with indicator light helps prevent machine damage if the duty cycle is exceeded or airflow is blocked. Suitable for welding all kinds of ru le and basic electrode. ...
The MDF (Main Distribution Frame)
The MDF (Main Distribution Frame)

Services and Service Equipment CEC-6
Services and Service Equipment CEC-6

... (neutral) supplying buildings housing livestock shall be grounded only at the source or main service. An accepted isolation of the grounded conductor (neutral) must be provided at the load end (e.g. insulated boot, heat shrink, rated rubber tape, or equivalent) to a point of termination on the neutr ...
Thermal Agitation of Electric Charge in Conductors
Thermal Agitation of Electric Charge in Conductors

Kosterev and Undrill
Kosterev and Undrill

THE 555 INTEGRATED CIRCUIT (IC) TIMER
THE 555 INTEGRATED CIRCUIT (IC) TIMER

Tutorial-2 (Week-5)
Tutorial-2 (Week-5)

... b) the power generated by the voltage source c) the current in the 48W resistor ...
Switches and Over Current Protective Devices
Switches and Over Current Protective Devices

< 1 ... 467 468 469 470 471 472 473 474 475 ... 584 >

Ground (electricity)



In electrical engineering, ground or earth is the reference point in an electrical circuit from which voltages are measured, a common return path for electric current, or a direct physical connection to the Earth.Electrical circuits may be connected to ground (earth) for several reasons. In mains powered equipment, exposed metal parts are connected to ground to prevent user contact with dangerous voltage if electrical insulation fails. Connections to ground limit the build-up of static electricity when handling flammable products or electrostatic-sensitive devices. In some telegraph and power transmission circuits, the earth itself can be used as one conductor of the circuit, saving the cost of installing a separate return conductor (see single-wire earth return).For measurement purposes, the Earth serves as a (reasonably) constant potential reference against which other potentials can be measured. An electrical ground system should have an appropriate current-carrying capability to serve as an adequate zero-voltage reference level. In electronic circuit theory, a ""ground"" is usually idealized as an infinite source or sink for charge, which can absorb an unlimited amount of current without changing its potential. Where a real ground connection has a significant resistance, the approximation of zero potential is no longer valid. Stray voltages or earth potential rise effects will occur, which may create noise in signals or if large enough will produce an electric shock hazard.The use of the term ground (or earth) is so common in electrical and electronics applications that circuits in portable electronic devices such as cell phones and media players as well as circuits in vehicles may be spoken of as having a ""ground"" connection without any actual connection to the Earth, despite ""common"" being a more appropriate term for such a connection. This is usually a large conductor attached to one side of the power supply (such as the ""ground plane"" on a printed circuit board) which serves as the common return path for current from many different components in the circuit.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report