• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
How to Set Control Voltage In an Application Circuit
How to Set Control Voltage In an Application Circuit

... external supply voltage. In most applications these pins are connected to the main power line/plane of the system. In addition, uPG2250T5N also has a control pin, Vcont, for the control of the PA. As indicated on the data sheet, Vcont should be set around 1.8V while VDD can be selected as high as 3. ...
View - Toshiba America Electronic Components
View - Toshiba America Electronic Components

... • The information contained herein is subject to change without notice. 021023_D • TOSHIBA is continually working to improve the quality and reliability of its products. Nevertheless, semiconductor devices in general can malfunction or fail due to their inherent electrical sensitivity and vulnerabil ...
Earth Fault Detection Basics in Theory
Earth Fault Detection Basics in Theory

... resistor RE. During this, only the star point of the generator that was initially connected will be earthed via the neutral earthing resistor RE. In case that the generator circuit breaker of the generator whose star point was connected with, the neutral earthing resistor is switched off by the corr ...
Series 70 ePODs: Type-P
Series 70 ePODs: Type-P

... The CB can only be disengaged/removed when in the off position, which eliminates the possibility of the creation of an arc or flash during breaker removal. When the CB is in the off position, access to the mounting screw is locked out. When the CB is in the on positions, access to the mounting screw ...
CN-0053 8/10/12/14位乘法DAC AD5450/AD5451/AD5452/AD5453 的精密、双极性配置.
CN-0053 8/10/12/14位乘法DAC AD5450/AD5451/AD5452/AD5453 的精密、双极性配置.

... instability in the closed loop. Typical values in the 1 pF to 5 pF range can be used. In any circuit where accuracy is important, careful consideration of the power supply and ground return layout helps to ensure the rated performance. The printed circuit board should be designed so that the analog ...


... AC and DC, Voltage and Current for measuring of currents e.g. at plants for own generation of electricity • Measuring input voltage AC/DC 600 V (pre-set 60/150/300/600 V) • Measuring input current AC/DC 5A (pre-set 1/5 A) • Zero and full scale for other ranges can be scaled by the user easil ...
Electricity and Circuits
Electricity and Circuits

... charge come into contact, they _____________. • When two objects with DIFFERENT charges come into contact, they _____________. ...
Series-Parallel DC Circuits - benchmark
Series-Parallel DC Circuits - benchmark

...  A series circuit may be used to connect small voltages to obtain high voltages.  High voltages may be reduced by connecting resistances in series.  Series circuits provide a means for reducing and controlling the current by connecting resistances in series.  Series circuits are used where diffe ...
ATT7030A Application Note
ATT7030A Application Note

... We should notice some points when design sampling input signal: 1. Whatever input method, the direct current bias voltage of input pin VxP and VxN should be 2.4V. The bias voltage must be provided by pin REFOUT (pin 11), or else the measurement precision couldn’t be assured. 2. For assuring measurem ...
02 electric power
02 electric power

... The delta-wye connection is shown in figure 2-11. Note that for the given turns ratios of 1:1 that the magnitude of the phase-to-phase output voltage is equal to the magnitude of the phase-to-phase input voltage multiplied by √3 . The input and output voltages of 3Ø transformers and 3Ø banks of sing ...
CRF-UL Application Note
CRF-UL Application Note

... primary issue for years. Typical fusible wirewound resistors are used when it’s required to pass some type of short transient event without failing. The CRF series are designed to be used as a precision safety resistor. This series are used where the electronic circuit need a more robust resistor, a ...
Isobar 8-Outlet Professional A/V Power Conditioning
Isobar 8-Outlet Professional A/V Power Conditioning

... Diagnostic LEDs report 4 operational conditions (protection, grounding, power, switched status) 10-ft. power cord with right-angle NEMA 5-15P plug permits convenient placement anywhere within Audio/Video systems. 1U rackmount or console design includes rackmount hardware and removable console feet ...
electric lineman protection using user changeable password based
electric lineman protection using user changeable password based

... person can operate it with a password. Here, there is also a provision of changing the password. The system is fully controlled by the 8 bit microcontroller of 8051 family. The password is stored in an EEPROM, interfaced to the microcontroller and the password can be changed any time unlike a fixed ...
Accurately measuring nanoamperes Using the Fluke 8808A
Accurately measuring nanoamperes Using the Fluke 8808A

... simple, because current leakage typically falls in the low microampere range, and measurements made with traditional DMMs can be inaccurate. The reason for the inaccuracies is that DMMs usually measure current by applying a known resistance in the form of a shunt resistor in series with the circuit ...
FY03 Warfighter Technical Council (WTC) IPR #1
FY03 Warfighter Technical Council (WTC) IPR #1

... embedded simulation capabilities into FCS platforms, including robotic Unmanned Ground Vehicles (UGV). The success of the AMPS STO can easily be extrapolated to any future military vehicular platform as well. ...
6-Outlet Industrial Surge Protector, 6
6-Outlet Industrial Surge Protector, 6

... Instruction manual ...
PDF
PDF

... Standard ...
Comparing Voltage Drops and Currents in Parallel Lab
Comparing Voltage Drops and Currents in Parallel Lab

... Demonstrate
how
to
use
the
voltage
probes
to
determine
a
voltage
difference
between
two
points.
 Make
sure
students
are
using
the
probes
correctly
and
not
wiring
the
voltage
probes
into
the
 circuit.

Make
sure
the
ammeters
are
being
wired
into
the
circuit,
in
series
with
the
resistors.
 Combining
t ...
Electricity Notes
Electricity Notes

... Experiment- Investigating Voltage How does the voltage of a component in a series circuit compare to the voltage of a component in a parallel circuit? The following two circuits are set up and the voltage is measured across both 1.5 V batteries and across each 1.5V bulb individually. ...
AC Source Tx and Thevenin
AC Source Tx and Thevenin

... voltage source and a resistor to an AC current source and a resistor. Apply Nodal Analysis to an AC Circuit. ...
article
article

... This new requirement is intended to reduce the occurrence of serious injury or death due to arcing faults to workers who work on or near energized electrical equipment. The warning label should remind a qualified worker who intends to open the equipment for analysis or work that a serious hazard exi ...
IEC Voltage Standard and Recommendation
IEC Voltage Standard and Recommendation

HMC735LP5 / 735LP5E
HMC735LP5 / 735LP5E

... 1,000 pF Capacitor, 0402 Pkg. ...
latchup
latchup

... Reduce the well and substrate resistances, producing lower voltage drops  higher substrate doping level reduces Rsub  reduce Rwell by making low resistance contact to GND  guard rings around p- and/or n-well, with frequent contacts to the rings, reduces the parasitic resistances. ...
Alternative quantities and electricity supply
Alternative quantities and electricity supply

... disconnection should be used, such that during an earth fault the voltage between simultaneously accessible exposed-and extraneous-conductive-parts are not to cause danger. The protective device may be either:  an overcurrent protective device, or  a residual current device (which is a preferred m ...
< 1 ... 427 428 429 430 431 432 433 434 435 ... 584 >

Ground (electricity)



In electrical engineering, ground or earth is the reference point in an electrical circuit from which voltages are measured, a common return path for electric current, or a direct physical connection to the Earth.Electrical circuits may be connected to ground (earth) for several reasons. In mains powered equipment, exposed metal parts are connected to ground to prevent user contact with dangerous voltage if electrical insulation fails. Connections to ground limit the build-up of static electricity when handling flammable products or electrostatic-sensitive devices. In some telegraph and power transmission circuits, the earth itself can be used as one conductor of the circuit, saving the cost of installing a separate return conductor (see single-wire earth return).For measurement purposes, the Earth serves as a (reasonably) constant potential reference against which other potentials can be measured. An electrical ground system should have an appropriate current-carrying capability to serve as an adequate zero-voltage reference level. In electronic circuit theory, a ""ground"" is usually idealized as an infinite source or sink for charge, which can absorb an unlimited amount of current without changing its potential. Where a real ground connection has a significant resistance, the approximation of zero potential is no longer valid. Stray voltages or earth potential rise effects will occur, which may create noise in signals or if large enough will produce an electric shock hazard.The use of the term ground (or earth) is so common in electrical and electronics applications that circuits in portable electronic devices such as cell phones and media players as well as circuits in vehicles may be spoken of as having a ""ground"" connection without any actual connection to the Earth, despite ""common"" being a more appropriate term for such a connection. This is usually a large conductor attached to one side of the power supply (such as the ""ground plane"" on a printed circuit board) which serves as the common return path for current from many different components in the circuit.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report