• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Conditioning a Switch-mode Power Supply Current Signal Using TI
Conditioning a Switch-mode Power Supply Current Signal Using TI

Paper 3
Paper 3

... Tripping ratio ...
1 - Brown University
1 - Brown University

design and implementation of a novel multilevel dc
design and implementation of a novel multilevel dc

... method of input capacitors are discussed. Finally, a laboratory prototype multilevel inverter with 400 V input voltage and output 220 V rms /2 kW is implemented. The multilevel inverter is controlled with sinusoidal pulse-width modulation (SPWM) by TMS320LF2407 digital signal processor (DSP). Experi ...
An investigation into the technical design, transient stability studies
An investigation into the technical design, transient stability studies

... standard that applies to all technologies. • IEEE 1547 addresses all types of interconnected generation up to 10 MW. • The 1547 standard has benefited greatly from earlier utility industry work documented in IEEE and IEC standards (ANSI- C37 series for protective relaying) ...
SOLITAIRE - SAM Electronics
SOLITAIRE - SAM Electronics

... The LCC is a fully controlled 3-phase thyristor bridge on the network side. The LCC is operated as a controlled rectifier and is used for setting the speed of the motor via the intermediate DC current and voltage. The MCC is used for converting the DC link voltage into AC of the required voltage and ...
Aalborg Universitet A CMOS Power Amplifier using Ground Separation Technique
Aalborg Universitet A CMOS Power Amplifier using Ground Separation Technique

... system requirements. In WCDMA 3GPP UE document, transmitter characteristics are specified at the antenna connector of the UE. There will likely be some devices between the PA output and the antenna terminals such as circulator, duplex filter, and switch(es) with several dB of loss. When making the c ...
Digital Devices
Digital Devices

... Source: David Harrison BR 6/07 ...
RFMD Datasheet Template
RFMD Datasheet Template

F5019 - Fuji Electric America
F5019 - Fuji Electric America

... 5. If you need to use a product in this Catalog for equipment requiring higher reliability than normal, such as for the equipment listed below, it is imperative to contact Fuji Electric Systems Co., Ltd. to obtain prior approval. When using these products for such equipment, take adequate measures s ...
Choose the best answer to each question and write the appropriate
Choose the best answer to each question and write the appropriate

... An electric heater is rated at 300 W for use in a 110-V circuit. The safety fuse in the circuit can handle 15A of current. How many heaters can be safely operated in the circuit? A) ...
High Current Test Sets - agea
High Current Test Sets - agea

Article for Elektuur – August 2008
Article for Elektuur – August 2008

... Table #1 and corresponding graph show the same situation above. In the first case, V1 receives almost the full signal ( still with a loss of 4% due to the other resistances in the circuit) and in the second a significantly reduced amplitude (3), with a loss of 17%. It is as if you had a volume contr ...
Phasor I
Phasor I

Balanced Line Driver SSM2142
Balanced Line Driver SSM2142

... The following data, taken from the THD test circuit on an Audio Precision System One using the internal 80 kHz noise filter, demonstrates the typical performance of a balanced pair system based on the SSM2142/SSM2141 chip set. Both differential and single-ended modes of operation are shown, under a ...
HigH-Power Current AmPliFier Applications F6300 Features
HigH-Power Current AmPliFier Applications F6300 Features

... The F6300 and F6150 combination can easily test all high-burden electromechanical relays. The burden presented by electromechanical relay-based protection schemes are very high, requiring high-power current sources to drive the necessary current. When used together, the F6300 and F6150 can deliver t ...
Ground isolation amplifier
Ground isolation amplifier

... third party's intellectual property rights or other proprietary rights, and further, assumes no liability of whatsoever nature in the event of any such infringement, or arising from or connected with or related to the use of such devices. Upon the sale of any such devices, other than for buyer's rig ...
127-10_Resonance
127-10_Resonance

transformers for wind turbine generators
transformers for wind turbine generators

Electric current is measured in units called amps
Electric current is measured in units called amps

... Electric current is measured in units called amps (A). The electric current is not used up by the components in a circuit but it transfers energy from the voltage source to the various components making up the circuit. Electric current is measured using an ammeter. ...
Aalborg Universitet Distribution Generation Units
Aalborg Universitet Distribution Generation Units

... ? Users may download and print one copy of any publication from the public portal for the purpose of private study or research. ? You may not further distribute the material or use it for any profit-making activity or commercial gain ? You may freely distribute the URL identifying the publication in ...
File
File

... The __ __ in the circuit is like a radiator. An electrical device uses electrical energy supplied by the circuit. Instead of a flow of water, electricity flows in an electrical circuit. The _______ are like pipes; they carry the electricity (called current) round the circuit. The electrical current ...
Applications of Low Power Current and Voltage Sensors
Applications of Low Power Current and Voltage Sensors

... of the resin result in a capacitance, which is bigger than the stray capacitance to ground. For this reason the influence of the stray capacitance to the accuracy is compensated and the behaviour within a defined frequency range is improved (see also chapter about Power Quality Measurement). LPVTs d ...
Tips for connecting 24-volt power
Tips for connecting 24-volt power

... KMC recommends that secondaries of transformers powering network devices be floating! Some conditions exist, however, that require that the secondary of a transformer be connected to earth ground. In the United States, for example: The National Electrical Code® requires (section 250.20) grounding tr ...
Chapter-10: Design Of Ehvand UHV Sub-Station
Chapter-10: Design Of Ehvand UHV Sub-Station

... The scheme should fit in the planning criteria used to design the connected transmission system. System should be stable if a permanent fault occurs on a line. It is, therefore, important to limit as much as possible the system un-stability caused by outage of line, transformer or generators due to ...
< 1 ... 420 421 422 423 424 425 426 427 428 ... 584 >

Ground (electricity)



In electrical engineering, ground or earth is the reference point in an electrical circuit from which voltages are measured, a common return path for electric current, or a direct physical connection to the Earth.Electrical circuits may be connected to ground (earth) for several reasons. In mains powered equipment, exposed metal parts are connected to ground to prevent user contact with dangerous voltage if electrical insulation fails. Connections to ground limit the build-up of static electricity when handling flammable products or electrostatic-sensitive devices. In some telegraph and power transmission circuits, the earth itself can be used as one conductor of the circuit, saving the cost of installing a separate return conductor (see single-wire earth return).For measurement purposes, the Earth serves as a (reasonably) constant potential reference against which other potentials can be measured. An electrical ground system should have an appropriate current-carrying capability to serve as an adequate zero-voltage reference level. In electronic circuit theory, a ""ground"" is usually idealized as an infinite source or sink for charge, which can absorb an unlimited amount of current without changing its potential. Where a real ground connection has a significant resistance, the approximation of zero potential is no longer valid. Stray voltages or earth potential rise effects will occur, which may create noise in signals or if large enough will produce an electric shock hazard.The use of the term ground (or earth) is so common in electrical and electronics applications that circuits in portable electronic devices such as cell phones and media players as well as circuits in vehicles may be spoken of as having a ""ground"" connection without any actual connection to the Earth, despite ""common"" being a more appropriate term for such a connection. This is usually a large conductor attached to one side of the power supply (such as the ""ground plane"" on a printed circuit board) which serves as the common return path for current from many different components in the circuit.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report