• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Electrical Installations Lab AEL-1 Advanced Electrical Laboratories (AEL-LABS):
Electrical Installations Lab AEL-1 Advanced Electrical Laboratories (AEL-LABS):

... On one hand, this area covers all those applications and trainers designed to study home electrical installations and industrial electrical installations. Besides, it includes a series of trainers to study the most common electrical faults generated in actual electrical installations. After simulati ...
Application guide No. 3193
Application guide No. 3193

... Damaging effects of transients and surges UL SPD Types and NEC® locations ...
T.C. Neugebauer and D.J. Perreault, “Parasitic Capacitance Cancellation in Filter Inductors,” IEEE Transactions on Power Electronics , Vol. 21, No. 1, January 2006, pp. 282-288.
T.C. Neugebauer and D.J. Perreault, “Parasitic Capacitance Cancellation in Filter Inductors,” IEEE Transactions on Power Electronics , Vol. 21, No. 1, January 2006, pp. 282-288.

... capacitance arises from capacitance between winding turns and from winding-to-core capacitance. The distributed parasitic components can be lumped together to form the lumped-parameter model for an inductor shown in Fig. 1(a) [1]–[4]. The impedance magnitude of a practical inductor as a function of ...
Electrical Probes
Electrical Probes

... technology for non-contact AC voltage detection uses the only button found on the test unit! Move from continuity testing to AC or DC voltage measurements without making a single adjustment. Magnets molded into the back of the unit allow for total lead control while testing. The versatility of this ...
IEEE white paper
IEEE white paper

... [7]. The high-frequency currents generate two phenomena in conductors: skin effect and proximity effect. Due to the skin effect the current, which flow through the conductor, is pushed towards the surface. When the current is divided among a group of parallel conductors the sharing of the total curr ...
Stakeholder Comment and Replies Matrix AESO AUTHORITATIVE DOCUMENT PROCESS Alberta Reliability Standard
Stakeholder Comment and Replies Matrix AESO AUTHORITATIVE DOCUMENT PROCESS Alberta Reliability Standard

... on R1.12. It is not clear which apparent impedance the AESO is referring to. Typically, if there is concern between line protection and line load capabilities, it is with the Zone 3 reach of the line protection. Is the AESO recommending that the zone reach causing concern be set to 125% of the appar ...
Standard-compliant switchgear and controlgear production
Standard-compliant switchgear and controlgear production

... assembly. For example, evidence of protective circuit function requires testing of a defined protective circuit arrangement in a defined enclosure construction. Tested, holistically designed system technology allows the verifications required by the standard to be successfully prepared. Clear design ...
Chapter4 DC Biasing BJT (part a)
Chapter4 DC Biasing BJT (part a)

... curves for this particular transistor we see that 30 mA (IB = 300 A) of collector current is best for maximum amplification, giving equal amount above and below the Q-point. Note that this is three different scenarios of collector current being viewed simultaneously. ...
2.5 Electrical Power 2.5.1 Class 1E Emergency Power Supply System
2.5 Electrical Power 2.5.1 Class 1E Emergency Power Supply System

... are essential to reactor shutdown, containment isolation and heat removal, reactor core cooling, and preventing a significant release of radioactive material to the environment. The EPSS distributes power to safety-related and non-safety-related plant loads during normal and abnormal operations. EPS ...
Steady State Operation and Control of Power
Steady State Operation and Control of Power

... systems, such as voltage control and protection, are based on the assumption that distribution systems are radial. In a radial distribution feeder, voltage decreases towards the end of the feeder, as loads cause a voltage drop. However, it will be altered with the presence of DG. DG will increase th ...
L9177 Datasheet - STMicroelectronics
L9177 Datasheet - STMicroelectronics

... lamp driver are controlled by SPI. The stepper motor driver is designed for a double winding coil motor, used for engine idle speed control. Low side drivers implement SR control to minimize emission. A protected 50 mA high side driver is provided. A Variable Reluctance Sensor interface allows the c ...
Functional description short white paper ASDS for Main
Functional description short white paper ASDS for Main

... For each inverter module in the ASDS system, there is an electronic DC-breaker. The main task for this electronic DC-breaker is to connect the inverter module to the DC-link and disconnect it if a critical fault occurs on the inverter module. The E-DCB will disconnect a module with a critical fault ...
Considerations for Using High-Impedance or Low
Considerations for Using High-Impedance or Low

Layout Design Guide
Layout Design Guide

... The Apalis and Colibri modules feature a range of high speed interfaces which need special treatment with regards to its PCB layout. This section describes a collection of basic rules to follow. It should be noted however that it is not often possible to follow all the rules. It is the job of the de ...
TND412 - The Changing ESD Landscape, ESD Protection
TND412 - The Changing ESD Landscape, ESD Protection

Switching, Operation/ Display and Control Devices
Switching, Operation/ Display and Control Devices

... Current Status and Future Outlook for Electric Distribution and Control Devices ...
Introduction - Sree Narayana Gurukulam College of Engineering
Introduction - Sree Narayana Gurukulam College of Engineering

... field system, armature and commutator. The field system is located on the stationary part of the machine called stator and consists of main poles, interpoles and frame or yoke. The main poles are designed to produce the magnetic flux. The interpoles are placed in between the main poles. They are emp ...
Using Monolithic High Voltage Gate Drivers
Using Monolithic High Voltage Gate Drivers

Voltage Support Provided by STATCOM in Unbalanced Power
Voltage Support Provided by STATCOM in Unbalanced Power

... Nowadays, there are grid operators that allow providing unbalanced currents so that the power at the PCC remains constant. This is very useful in weak grids because it allows connecting all loads to a balanced PCC voltage, which is especially important for sensitive loads that could disconnect if th ...
HDE Short Form Product Catalog
HDE Short Form Product Catalog

... a unique method of phasing across a single-phase or three-phase system to make certain that correct polarity has been established prior to “closing-in” a switch. The TAG-5000 consists of two units, a transmitter and receiver, which communicate via a radio frequency signal, thus eliminating the need ...
1.4 documentation
1.4 documentation

... The frame shall be constructed of painted steel and pop riveted to provide a strong substructure. The cabinet shall be a freestanding NEMA type 1 enclosure and meet IP10 requirements. The enclosure shall be mounted on four (4) heavy-duty swivel casters for portability and ease of installation and sh ...
medium-voltage switchgear
medium-voltage switchgear

8. Molded Case Circuit Breakers
8. Molded Case Circuit Breakers

... temperature. At ambient temperatures below 40°C, the breaker carries more current than its continuous current rating. The mechanical operation of the breaker could be affected if the temperature is significantly below the 40°C standard. The breakers will carry less current than their continuous rati ...
Specification for Ring Main Unit Switchgear with circuit breakers
Specification for Ring Main Unit Switchgear with circuit breakers

... The MV/LV tee-off transformer shall be protected by circuit-breaker, or by fuse-switch combination. h) Disconnecting circuit breaker The circuit breakers shall be low pressure SF6 or vacuum interrupter type. It shall be maintenance free. The position of the power and earthing contacts shall be clear ...
replacing batteries
replacing batteries

... The switch should be connected to a normally open switch contact. External voltage is not required; the switch is driven by 12V internal supply. In closed condition, 2mA of current are drawn The EPO switch is internally powered by the UPS for use with non-powered switch circuit breakers. The EPO cir ...
< 1 ... 37 38 39 40 41 42 43 44 45 ... 584 >

Ground (electricity)



In electrical engineering, ground or earth is the reference point in an electrical circuit from which voltages are measured, a common return path for electric current, or a direct physical connection to the Earth.Electrical circuits may be connected to ground (earth) for several reasons. In mains powered equipment, exposed metal parts are connected to ground to prevent user contact with dangerous voltage if electrical insulation fails. Connections to ground limit the build-up of static electricity when handling flammable products or electrostatic-sensitive devices. In some telegraph and power transmission circuits, the earth itself can be used as one conductor of the circuit, saving the cost of installing a separate return conductor (see single-wire earth return).For measurement purposes, the Earth serves as a (reasonably) constant potential reference against which other potentials can be measured. An electrical ground system should have an appropriate current-carrying capability to serve as an adequate zero-voltage reference level. In electronic circuit theory, a ""ground"" is usually idealized as an infinite source or sink for charge, which can absorb an unlimited amount of current without changing its potential. Where a real ground connection has a significant resistance, the approximation of zero potential is no longer valid. Stray voltages or earth potential rise effects will occur, which may create noise in signals or if large enough will produce an electric shock hazard.The use of the term ground (or earth) is so common in electrical and electronics applications that circuits in portable electronic devices such as cell phones and media players as well as circuits in vehicles may be spoken of as having a ""ground"" connection without any actual connection to the Earth, despite ""common"" being a more appropriate term for such a connection. This is usually a large conductor attached to one side of the power supply (such as the ""ground plane"" on a printed circuit board) which serves as the common return path for current from many different components in the circuit.