• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Preparation of Papers for IUST International Journal of Engineering
Preparation of Papers for IUST International Journal of Engineering

... look-ahead load margin to voltage collapse, due to either saddle-node bifurcation or the limit-induced bifurcation, is proposed. In [1], a static approach based on both optimal load flow (OLF), conventional load flow (LF) solutions and singular value decomposition of the load flow Jacobian matrix (J ...
UFC 3-540-01 Engine-Driven Generator Systems for
UFC 3-540-01 Engine-Driven Generator Systems for

... planning, design, construction, sustainment, restoration, and modernization criteria, and applies to the Military Departments, the Defense Agencies, and the DoD Field Activities in accordance with USD (AT&L) Memorandum dated 29 May 2002. UFC will be used for all DoD projects and work for other custo ...
Basic Electronics Competency Requirements
Basic Electronics Competency Requirements

... Describe electrical shock and its causes List the effects of electric current on the human body Explain shock hazards when working around power sources Identify sources of static charges and its damage to sensitive components 1.4.1 Describe static charge prevention straps, mats and grounding List to ...
North Yaran Oil Field Development
North Yaran Oil Field Development

... selected and coordinated to insure that the closest interrupter to the point of short circuit (or high overload) shall open first and minimize disturbances on the rest of the system. 6.7 Generally spare parts shall be in the form of individual parts except for capital spares that are in complete set ...
Transmission Lines
Transmission Lines

... gradient of a scalar electrostatic potential. Then, the third equation becomes Laplace’s equation for the potential. Thus, the electric field can be obtained from: ...
Voltage management
Voltage management

RZM002P02
RZM002P02

... The content specified herein is subject to change for improvement without notice. The content specified herein is for the purpose of introducing ROHM's products (hereinafter "Products"). If you wish to use any such Product, please be sure to refer to the specifications, which can be obtained from RO ...
NCP1565 - Highly Integrated Dual-Mode Active
NCP1565 - Highly Integrated Dual-Mode Active

4 chapter AC motors starting and protection systems
4 chapter AC motors starting and protection systems

17 Generator and Generator Transformer Protection
17 Generator and Generator Transformer Protection

SSC9522S Data Sheet
SSC9522S Data Sheet

... alternatively turned on and off. The on time and off time of them are equal. There is a dead time between Q(H) on period and Q(L) on period. During the dead time, both Q(H) and Q(L) are in off status. The current resonant power supply is controlled by the frequency control. When the output voltage d ...
APT 2.4kV-15kV Automatic Transfer Switchgear (MV ATS)
APT 2.4kV-15kV Automatic Transfer Switchgear (MV ATS)

... your project. Also delete any other items or paragraphs that does not apply. also be charged by the manual handle supplied on each circuit breaker for manual emergency closing or testing. ...
PLANNING LEVELS FOR HARMONIC VOLTAGE DISTORTION
PLANNING LEVELS FOR HARMONIC VOLTAGE DISTORTION

... Summary of THD Planning Levels .................................................................. .9 Planning Levels for Harmonic Voltages in 400V Systems .............................. 10 Planning Levels for Harmonic Voltages in 6.6kV, 11kV, and 20kV Systems .. 10 Planning Levels for Harmonic Volta ...
US ARMY ENGINEER SCHOOL
US ARMY ENGINEER SCHOOL

... Many devices have wiring holes to speed up the installation of conductors. This procedure is called back feeding or back wiring. When troubleshooting, examine the wiring holes for loose or poor connections. Wiring holes are used with solid wire only; good connections are not made with stranded wires ...
Testing High Voltage Breakers
Testing High Voltage Breakers

www.BDTIC.com/FAIRCHILD 1V5KE6V8(C)A - 1V5KE440(C)A 1500 W Transient Voltage Suppressors 1V5KE6V8(C)A - 1V5KE440(C)A —
www.BDTIC.com/FAIRCHILD 1V5KE6V8(C)A - 1V5KE440(C)A 1500 W Transient Voltage Suppressors 1V5KE6V8(C)A - 1V5KE440(C)A —

... Counterfeiting of semiconductor parts is a growing problem in the industry. All manufacturers of semiconductor products are experiencing counterfeiting of their parts. Customers who inadvertently purchase counterfeit parts experience many problems such as loss of brand reputation, substandard perfor ...
PAM8010 Description Pin Assignments
PAM8010 Description Pin Assignments

... 2. When the PAM8010 works without LC filters, it's better to add a ferrite chip bead at the outgoing line of speaker for suppressing the possible electromagnetic interference. 3. The absolute maximum rating of the PAM8010 operation voltage is 6.0V. When the PAM8010 is powered with four battery cells ...
Request for Bids_NE Starkville VCBs_2016-01-11
Request for Bids_NE Starkville VCBs_2016-01-11

... Bidders shall complete all blank spaces on the Materialman’s Proposal Form for each item of equipment being bid in accordance with these specifications and terms and conditions. Bidder should insert the unit price in the blank under the Unit Price heading and multiply this unit price by the number ...
MAX8759 Low-Cost, SMBus, CCFL Backlight Controller General Description Features
MAX8759 Low-Cost, SMBus, CCFL Backlight Controller General Description Features

Application Notes Relays - ZETTLER electronics GmbH
Application Notes Relays - ZETTLER electronics GmbH

... Even at low voltages and currents of less than 100 mA, electrical discharge effects occur at opening and closing of contacts. At higher values (e.g. from 12 V / 0.4 A at Ag contacts) thermal arcs may occur; a current is still flowing although the contact has already opened. If the contact gap is big e ...
Comparison of Distribution Transformer Losses and Capacity under
Comparison of Distribution Transformer Losses and Capacity under

... Harmonic currents and voltages are created by nonlinear loads connected on the power system. Harmonic distortion is a form of pollution in the electric plant that can cause problems if the sum of the harmonic currents increases above certain limits. All power electronic converters used in different ...
megablock series
megablock series

... communications systems, fieldbus uses a bus topology with multi-drop wiring. While this offers opportunities for significant cost savings relative to the point-to-point wiring used in 4-20 mA systems, it also poses a risk to control system reliability and availability. Because transmitters on a fiel ...
Application guide No. 3193
Application guide No. 3193

... Damaging effects of transients and surges UL SPD Types and NEC® locations ...
ABWR 2.12  Station Electrical Systems 2.12.1  Electrical Power Distribution System
ABWR 2.12 Station Electrical Systems 2.12.1 Electrical Power Distribution System

... The UATs are sized to supply their load requirements, during design operating modes, of their respective Class 1E divisions and non-Class 1E load groups. UATs are separated from the RAT(s). In addition, UATs are provided with their own oil pit, drain, fire deluge system, grounding, and lightning pro ...
REF191 数据手册DataSheet 下载
REF191 数据手册DataSheet 下载

... Initial accuracy includes temperature hysteresis effect. Line and load regulation specifications include the effect of self-heating. Long-term stability specification is noncumulative. The drift in subsequent 1000-hour periods is significantly lower than in the first 1000-hour period. ...
< 1 ... 36 37 38 39 40 41 42 43 44 ... 584 >

Ground (electricity)



In electrical engineering, ground or earth is the reference point in an electrical circuit from which voltages are measured, a common return path for electric current, or a direct physical connection to the Earth.Electrical circuits may be connected to ground (earth) for several reasons. In mains powered equipment, exposed metal parts are connected to ground to prevent user contact with dangerous voltage if electrical insulation fails. Connections to ground limit the build-up of static electricity when handling flammable products or electrostatic-sensitive devices. In some telegraph and power transmission circuits, the earth itself can be used as one conductor of the circuit, saving the cost of installing a separate return conductor (see single-wire earth return).For measurement purposes, the Earth serves as a (reasonably) constant potential reference against which other potentials can be measured. An electrical ground system should have an appropriate current-carrying capability to serve as an adequate zero-voltage reference level. In electronic circuit theory, a ""ground"" is usually idealized as an infinite source or sink for charge, which can absorb an unlimited amount of current without changing its potential. Where a real ground connection has a significant resistance, the approximation of zero potential is no longer valid. Stray voltages or earth potential rise effects will occur, which may create noise in signals or if large enough will produce an electric shock hazard.The use of the term ground (or earth) is so common in electrical and electronics applications that circuits in portable electronic devices such as cell phones and media players as well as circuits in vehicles may be spoken of as having a ""ground"" connection without any actual connection to the Earth, despite ""common"" being a more appropriate term for such a connection. This is usually a large conductor attached to one side of the power supply (such as the ""ground plane"" on a printed circuit board) which serves as the common return path for current from many different components in the circuit.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report