• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
(b) DAC0808
(b) DAC0808

... A negative reference voltage may be used if R14 is grounded and the reference voltage is applied to R15 as shown in Figure 8 . A high input impedance is the main advantage of this method. Compensation involves a capacitor to VEE on pin 16, using the values of the previous paragraph. The negative ref ...
Voltage Rating
Voltage Rating

... the two ratings is for overcurrents at line-to-ground voltages, intended to be cleared by one pole of the device. The higher of the two ratings is for overcurrents at line-to-line voltages, intended to be cleared by two or three poles of the circuit breaker or other mechanical overcurrent device. Sl ...
Automatic Street Light Control
Automatic Street Light Control

... manufactured in different shapes, colors and sizes. For their low price, low consumption and simple use, they have almost completely pushed aside other light sources- bulbs at first place. They perform similar to common diodes with the difference that they emit light when current flows through them. ...
277 Volts to your Server? - Engineered Systems Magazine
277 Volts to your Server? - Engineered Systems Magazine

... Presently, most server power supplies in North America operate at 208V. Several strategies have been developed to increase the efficiency of the data center such as operating data centers at 400Y230V. However, many “legacy” North American computers / servers are not designed to operate at voltages h ...
Chapter 1
Chapter 1

... computer case and how they connect together and are compatible • Learn how to protect yourself and the equipment against the dangers of electricity when working inside a computer case • Learn about tools you will need as a PC hardware technician and safety precautions when working around computer eq ...
STL128D
STL128D

... High voltage fast-switching NPN power transistor ...
Technical White Paper SolarEdge Single Phase Inverter System
Technical White Paper SolarEdge Single Phase Inverter System

... the requirements of Article 690.35 (C) (1), (2) and (3) apply. Each power optimizer monitors its connected modules and communicates any detected fault to the inverter. The inverter monitors the conductors between the power optimizers and the inverter. In response to a ground fault the inverter will ...
Power Electronics 4th year elective
Power Electronics 4th year elective

... There has long been two schools of thought in the medical world regarding the sequela of electric shock. One school believed that the consequential damage to tissue developed over time requiring long hospitalisation and repeated surgical intervention to remove dead tissue whilst the other school hel ...
Wireless Starting Of 3 Phase Induction Motor
Wireless Starting Of 3 Phase Induction Motor

... conduct current only in one direction), TRIACs are bidirectional and so current can flow through them in either direction. Another difference from SCRs is that TRIACs can be triggered by either a positive or a negative current applied to its gate electrode, whereas SCRs can be triggered only by curr ...
Document
Document

... Explain why a relay is needed for a logic gate to switch a current in a mains circuit: • a logic gate is a low power device that would be damaged if exposed directly to mains power • the relay isolates the low voltage in the sensing circuit from the high voltage mains. ...
MIL EMI and Transient Solutions
MIL EMI and Transient Solutions

... sometimes called “peaking”. Layout of the filter is very important to avoid inadvertent parasitic coupling. For the example filter above, parasitic capacitance from input to output could easily be 1pF, which is about 60K ohms at 2.7 Mhz. If there were no shunt impedance looking back into the filter ...
Ohm`s Law - Goodheart
Ohm`s Law - Goodheart

section 16412 low voltage molded case circuit breakers
section 16412 low voltage molded case circuit breakers

Form B - Hydro One Brampton
Form B - Hydro One Brampton

... Refer to Hydro One Brampton’s Conditions of Service on our website at www.HydroOneBrampton.com for Technical Requirements for connection. IMPORTANT: All fields below are mandatory, except where noted. Incomplete applications may be returned by Hydro One Brampton Networks Inc. (“Hydro One Brampton”). ...
PRO 3500 - Monster
PRO 3500 - Monster

... 1. ON/OFF Switch: Once the PowerCenter is plugged into a properly grounded 120V outlet, operating the switch will provide AC power to the components plugged into the PowerCenter’s Switched and Switched (Timed) outlets. Release this button to shut down components. 2. Ground OK: When this LED is On, t ...
Arc Flash Hazards
Arc Flash Hazards

... The new IEEE Std. 1584-2002 – “Guide for Performing Arc Flash Hazard Calculations” provides users the newest methods of arc flash hazard analysis. In addition, IEEE Std. 1584-2002 applies to a wider range of available fault currents (from 700A to 106kA) compared to current issue of NFPA 70E (from 16 ...
STN93003
STN93003

... maintaining the wide RBSOA. The STN93003 is expressly designed for a new solution to be used in compact fluorescent lamps, where it is coupled with the STN83003, its complementary NPN transistor. ...
M - Chauvin Arnoux
M - Chauvin Arnoux

... - calculate the short-circuit current and size the circuit-breaker for the installation (TN-type installation). This measurement is not possible on an IT-type installation, however, because of the high earthing impedance of the power supply transformer or even its total isolation in relation to t ...
11 - KUET
11 - KUET

... machine via an active electrode through the patient body tissues and then returned back to the diathermy machine via a dispersive electrode (patient return pad) ...
ENT 163 10-08 - UniMAP Portal
ENT 163 10-08 - UniMAP Portal

...  From C to D – the rate at which the loop cuts the flux lines increases to a maximum at D, and then back to minimum again at A.  Recall from Faraday’s law:  When a wire moves through a magnetic field, a voltage is induced.  According to Faraday’s Law – amount of induced voltage is proportional t ...
Fundamentals of Power Electronics and Power System with MATLAB
Fundamentals of Power Electronics and Power System with MATLAB

... • Building the Electrical Circuit with powerlib Library ...
Lecture 1410
Lecture 1410

... The coil on which we apply the voltage to be changed is called the "primary" and it has N P turns. The transformer output appears on the second coils which is known as the "secondary" and has N S turns. The role of the iron core is to insure that the magnetic field lines from one coil also pass thro ...
Common-emitter circuit
Common-emitter circuit

... Materials that prevent the flow of electricity ...
Data sheets - Sauter Controls
Data sheets - Sauter Controls

... The initialisation is performed by short-circuiting the two “Ini” half-moon buttons (under the housing cover) for 1-2 seconds. The effect of this is that the universal controller deletes the entire RAM and ...
Varistors SMOV34S Datasheet
Varistors SMOV34S Datasheet

... The Littelfuse SMOV thermally protected varistor is a selfprotected device. It consists of a 34mm square varistor with an integral thermal disconnect designed to open in the event of overheating due to abnormal overvoltage as outlined in UL1449 3rd edition. The SMOV helps facilitate SPD module compl ...
< 1 ... 361 362 363 364 365 366 367 368 369 ... 584 >

Ground (electricity)



In electrical engineering, ground or earth is the reference point in an electrical circuit from which voltages are measured, a common return path for electric current, or a direct physical connection to the Earth.Electrical circuits may be connected to ground (earth) for several reasons. In mains powered equipment, exposed metal parts are connected to ground to prevent user contact with dangerous voltage if electrical insulation fails. Connections to ground limit the build-up of static electricity when handling flammable products or electrostatic-sensitive devices. In some telegraph and power transmission circuits, the earth itself can be used as one conductor of the circuit, saving the cost of installing a separate return conductor (see single-wire earth return).For measurement purposes, the Earth serves as a (reasonably) constant potential reference against which other potentials can be measured. An electrical ground system should have an appropriate current-carrying capability to serve as an adequate zero-voltage reference level. In electronic circuit theory, a ""ground"" is usually idealized as an infinite source or sink for charge, which can absorb an unlimited amount of current without changing its potential. Where a real ground connection has a significant resistance, the approximation of zero potential is no longer valid. Stray voltages or earth potential rise effects will occur, which may create noise in signals or if large enough will produce an electric shock hazard.The use of the term ground (or earth) is so common in electrical and electronics applications that circuits in portable electronic devices such as cell phones and media players as well as circuits in vehicles may be spoken of as having a ""ground"" connection without any actual connection to the Earth, despite ""common"" being a more appropriate term for such a connection. This is usually a large conductor attached to one side of the power supply (such as the ""ground plane"" on a printed circuit board) which serves as the common return path for current from many different components in the circuit.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report