• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Tech Spec - Cooper Bussmann
Tech Spec - Cooper Bussmann

... The new IEEE Std. 1584-2002 – “Guide for Performing Arc Flash Hazard Calculations” provides users the newest methods of arc flash hazard analysis. In addition, IEEE Std. 1584-2002 applies to a wider range of available fault currents (from 700A to 106kA) compared to current issue of NFPA 70E (from 16 ...
14 Current and Voltage Measurements
14 Current and Voltage Measurements

... IM =
Digital Systems: Combinational Logic Circuits
Digital Systems: Combinational Logic Circuits

... to ground; (b) IC input internally shorted to supply voltage. These two types of failures force the input signal at the shorted pin to stay in the same state. (c) IC output internally shorted to ground; (d) output internally shorted to supply voltage. These two failures do not affect signals at the ...
Fast Opening Switch Approach for High-Voltage Vacuum
Fast Opening Switch Approach for High-Voltage Vacuum

FEB109-001 User`s Guide 300 Watt Power Factor Corrected Supply
FEB109-001 User`s Guide 300 Watt Power Factor Corrected Supply

... The ML4821 Evaluation Board contains both high impedance/low level and low impedance/high level circuits. Because of this, careful attention must be used for component placement, grounding, and PC trace routing. The ML4821 uses a ground plane with power components (Q1, C17, R4) placed so as not to i ...
Improvement of Power Quality in Distribution System
Improvement of Power Quality in Distribution System

Pre lab and Lab 4 for elec 3105 Transformer [no Amplifiers]
Pre lab and Lab 4 for elec 3105 Transformer [no Amplifiers]

interline unified power quality conditioner: design and
interline unified power quality conditioner: design and

... The VSC switching strategy is based on a sinusoidal PWM technique which offers simplicity and good response. Since custom power is a relatively low power application, PWM methods offer a more flexible option than the fundamental frequency switching (FFS) methods favored in FACTS applications. Beside ...
open file - PowerLogic
open file - PowerLogic

... compressor would periodically shut down, often with catastrophic results to the plant, when nothing else in the plant was affected. The facilities engineer configured the POWERLOGIC CM-2350 Circuit Monitor on the circuit to capture waveforms during voltage sag events. The problem soon recurred, and, ...
Bus Edison High Speed Fuse Application
Bus Edison High Speed Fuse Application

... The non regenerative thyristor drive is widely used for variable speed control of motors. In these applications the coordination of fuses and semiconductors is often more critical than for rectifiers. The fuses are usually positioned in each arm of the bridge or the supply lines and will generally o ...
Electrical Systems and Construction Student`s Book
Electrical Systems and Construction Student`s Book

... Electric power is transmitted over very long distances so the resistance of the conductors carrying the current is substantial. Transmitting power at low currents and high voltages through conductors with a significant resistance minimises conductor losses. When current flowing through a conductor e ...
Bipolar Power Transistor 30V 1.5A PNP PCP
Bipolar Power Transistor 30V 1.5A PNP PCP

... SANYO Semiconductor Co.,Ltd. assumes no responsibility for equipment failures that result from using products at values that exceed, even momentarily, rated values (such as maximum ratings, operating condition ranges, or other parameters) listed in products specifications of any and all SANYO Semico ...
Effects of an Electric Current and Domestic Circuits
Effects of an Electric Current and Domestic Circuits

... the air around them. Electricity and Death The hazards of electricity (see table below) depend on the amount of electrical current, its frequency, its duration, its path through the body, and the physical condition of the person. Alternating current at 60 Hz is slightly more dangerous than direct cu ...
SpecificationS - Technical Diagnostic Services
SpecificationS - Technical Diagnostic Services

... Ground Resistance testing using the 2 clamp method (no auxiliary rods needed) using optional current probes • 2- and 4-Wire Bond Resistance/Continuity Measurement (DC Resistance) with automatic polarity reversal • 3-Point Fall-of-Potential measurement with manual or automatic frequency selection • ...
Bulk Metal® Foil Resistors
Bulk Metal® Foil Resistors

... • Current sensing is best achieved with a Kelvin connection, which  removes the unwanted influences of lead resistance and lead  sensitivity to temperature • Other requirements such as high stability and short thermal  stabilization time when the power changes may dictate a special  resistor design ...
P0024_pdf - Acuity Brands
P0024_pdf - Acuity Brands

... 3. To reduce the risk of fire and burns, do not install this lighting system where the exposed bare connectors can be shorted or contact any conductive materials. 4. To reduce the risk of fire and overheating, make sure all connections are tight. 5. Do not install any luminaire closer than 6 inch ...
- Solution manuals
- Solution manuals

...  alternating current (AC) Current that cycles back and forth rather than traveling in only one direction. In the United States, the AC voltage from a standard wall outlet is normally between 110 and 115V. In Europe, the standard AC voltage from a wall outlet is 220V.  amp A measure of electrical c ...
Fire resistance
Fire resistance

...  a mechanical jointing unit ensuring rigid assembly of two components. The continuity of the protection conductor is ensured automatically. Proper tightening at the end of the assembly operation is ensured by a captive screw with a notched base (2). The two components are instantly assembled. Elect ...
Hot-Swapping Virtex-II, Virtex-II Pro, Virtex-4, and Virtex-5 Devices Summary
Hot-Swapping Virtex-II, Virtex-II Pro, Virtex-4, and Virtex-5 Devices Summary

Productivity
Productivity

... in place. (Figure 1) Multiple channels can also be provided for data/com, A/V and other low voltage systems which is installed at the same time by the same craftsperson with the same supporting means. Time studies and field experience demonstrate that prewired raceway installs in about one-third the ...
borri 4000
borri 4000

... 4000 can be interfaced to building management systems and network controlled via SNMP, Novell, Windows NT, Unix, DEC and IBM to name but a few. The connectivity ...
Circuit Breakers
Circuit Breakers

Bip Transistor 15V 600mA VCE(sat);300mV NPN Single SSFP
Bip Transistor 15V 600mA VCE(sat);300mV NPN Single SSFP

... system, safety equipment etc.) that shall require extremely high level of reliability and can directly threaten human lives in case of failure or malfunction of the product or may cause harm to human bodies, nor shall they grant any guarantee thereof. If you should intend to use our products for new ...
ARC FAULT CIRCUIT INTERRUPTER
ARC FAULT CIRCUIT INTERRUPTER

... insufficient energy to open the overcurrent device. This can cause arcing that can propel particles of molten metal onto nearby combustibles. ...
FJP13009 High Voltage Fast-Switching NPN Power Transistor FJP13009  High V
FJP13009 High Voltage Fast-Switching NPN Power Transistor FJP13009 High V

... SYSTEMS WITHOUT THE EXPRESS WRITTEN APPROVAL OF FAIRCHILD SEMICONDUCTOR CORPORATION. As used herein: 1. Life support devices or systems are devices or systems which, (a) are intended for surgical implant into the body or (b) support or sustain life, and (c) whose failure to perform when properly use ...
< 1 ... 344 345 346 347 348 349 350 351 352 ... 584 >

Ground (electricity)



In electrical engineering, ground or earth is the reference point in an electrical circuit from which voltages are measured, a common return path for electric current, or a direct physical connection to the Earth.Electrical circuits may be connected to ground (earth) for several reasons. In mains powered equipment, exposed metal parts are connected to ground to prevent user contact with dangerous voltage if electrical insulation fails. Connections to ground limit the build-up of static electricity when handling flammable products or electrostatic-sensitive devices. In some telegraph and power transmission circuits, the earth itself can be used as one conductor of the circuit, saving the cost of installing a separate return conductor (see single-wire earth return).For measurement purposes, the Earth serves as a (reasonably) constant potential reference against which other potentials can be measured. An electrical ground system should have an appropriate current-carrying capability to serve as an adequate zero-voltage reference level. In electronic circuit theory, a ""ground"" is usually idealized as an infinite source or sink for charge, which can absorb an unlimited amount of current without changing its potential. Where a real ground connection has a significant resistance, the approximation of zero potential is no longer valid. Stray voltages or earth potential rise effects will occur, which may create noise in signals or if large enough will produce an electric shock hazard.The use of the term ground (or earth) is so common in electrical and electronics applications that circuits in portable electronic devices such as cell phones and media players as well as circuits in vehicles may be spoken of as having a ""ground"" connection without any actual connection to the Earth, despite ""common"" being a more appropriate term for such a connection. This is usually a large conductor attached to one side of the power supply (such as the ""ground plane"" on a printed circuit board) which serves as the common return path for current from many different components in the circuit.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report