• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
High Performance VLSI Design Using Body Biasing in Domino
High Performance VLSI Design Using Body Biasing in Domino

... VLSI circuits. These dynamic circuits are often favoured in high performance designs because of the speed advantage offered over static CMOS logic. The main drawbacks of dynamic logic are a lack of design automation, a decreased tolerance to noise and increased power dissipation. This work discusses ...
AC Interference on Pipeline from Power Line Fault
AC Interference on Pipeline from Power Line Fault

... • With good engineering, there is no technical basis to seek alternate pipe or power line routes because of AC interference. AC mitigation systems can be reliably monitored and maintenance friendly. • Practical mitigation designs with pipeline operator input is essential. In the presence of AC, exce ...
How to Define the LF Driver`s Key Parameters in
How to Define the LF Driver`s Key Parameters in

... ATA5791single-chip key fob controller featuring a typical sensitivity of 1mVpeak-peak integrating the RF transmitter. There are several critical aspects for the LF antenna driver system design which need to be considered: •  Ability to generate sufficient magnetic field to detect the key fob inside ...
MIC79110 - Microchip
MIC79110 - Microchip

... The MIC79110 features constant voltage and constant current output to correctly charge lithium-ion batteries. The constant voltage is either 4.2V or adjustable. The constant current is set by the RSET pin and is constant down to around 300mV. Since RSET can be set below 500mA, the minimum output cur ...
Transformer - KFUPM Faculty List
Transformer - KFUPM Faculty List

... Three phase transformers are used throughout industry to change values of threephase voltage and current. Since three-phase power is the most common way in which power is produced, transmitted, and used, an understanding of how three phase transformer connections are made is essential. In this secti ...
THE NEW SOURCE OF POWER
THE NEW SOURCE OF POWER

... family is ideally suited to a life on the road powering mobile ...
The Intersil ICL7107 is high performance Included are seven
The Intersil ICL7107 is high performance Included are seven

... The ICL7107 is a high accuracy, versatility, and true economy. It features auto zero to less than 10µV, zero drift of less than 1µV/oC, input bias current of 10pA (Max), and rollover error of less than one count. True differential inputs and reference are useful in all systems, but give the designer ...
the garabi 2000 mw interconnection back-to-back hvdc
the garabi 2000 mw interconnection back-to-back hvdc

... presented little problem. The long 60 Hz line was a considerable challenge to avoid compensation at an intermediate point. For the chosen transmission line parameters, the short circuit capacity at the Garabi phase two 60 Hz side is about 2000 MVA, dropping to about 1600 MVA under contingency condit ...
Economic Power P $ = E x F units [8]
Economic Power P $ = E x F units [8]

MAX® 5500 ACRegenerator™ Owner`s Manual
MAX® 5500 ACRegenerator™ Owner`s Manual

... circuits are designed to eliminate the noise contamination of the AC power that is most detrimental to the performance of analog or video components like stereo receivers, VCRs or televisions. The two dedicated filters are carefully engineered to provide power filtration and inter-component noise is ...
ad515a data sheet
ad515a data sheet

Direct Drive Lead Acid Battery Desulfator (Type−3 "Jackhammer")
Direct Drive Lead Acid Battery Desulfator (Type−3 "Jackhammer")

... Brief Description. Most lead acid battery desulfators out there use a flyback design with inductors. While this does work, the inductor can only hold so much energy each pulse. If the battery has a high resistance, that energy won’t be absorbed very well and will show up as a very high voltage spike ...
AN11 - Designing Linear Circuits for 5V Single Supply Operation
AN11 - Designing Linear Circuits for 5V Single Supply Operation

... power supplies have been used to run the linear components (see Box, “Linear Power Supplies—Past, Present, and Future”). Recently, there has been increasing interest in powering linear circuits directly from the 5V logic rail. The logic rail is a difficult place for analog components to function. The ...
G:\Power Management\7937\HT7937v150-20160625.vp
G:\Power Management\7937\HT7937v150-20160625.vp

... The information appearing in this Data Sheet is believed to be accurate at the time of publication. However, Holtek assumes no responsibility arising from the use of the specifications described. The applications mentioned herein are used solely for the purpose of illustration and Holtek makes no wa ...
laboratory works semiconductor electronics
laboratory works semiconductor electronics

pub2949ogeneratorsmay2011
pub2949ogeneratorsmay2011

... • Let the engine cool off before refueling. • The generator should be kept a safe distance from structures because of engine heat. • Place the generator on a level surface to keep oil at the proper level throughout the engine. • Water will damage generators as well as produce an electrical h ...
FULLY PROTECTED LOW SIDE SWITCH
FULLY PROTECTED LOW SIDE SWITCH

CHAPTER 12:  PRINTED CIRCUIT BOARD (PCB) DESIGN ISSUES  SECTION 12.1: PARTITIONING
CHAPTER 12: PRINTED CIRCUIT BOARD (PCB) DESIGN ISSUES SECTION 12.1: PARTITIONING

... Figure 12.4: Use of a Sense Connection Moves Accuracy to the Load Point The use of separate force (F) and sense (S) connections (often referred to as a Kelvin connection) at the load removes any errors resulting from voltage drops in the force lead, but, of course, may only be used in systems where ...
Technical diagnostics for power apparatus
Technical diagnostics for power apparatus

... and it is an importent component of the safety regarding the endangering freedom and of the reliability regarding the freedom of defects and faults. The aim of diagnostics is to get relevant information about the condition of equipment and to derive from these informations criterious or limits to ch ...
installer manual
installer manual

... Electric fences shall be installed and operated so that they cause no electrical hazard to persons, animals or their surroundings. Electric fence constructions which are likely to lead to the entanglement of animals or persons shall be avoided. An electric fence shall not be supplied from two differ ...
Micrologic control units
Micrologic control units

... Micrologic P control units include all the functions offered by Micrologic A. In addition, they measure voltages and calculate power and energy values. They also offer new protection functions based on currents, voltages, frequency and power reinforce load protection in real time. ...
LGK-ID
LGK-ID

... relevant phenomenon is normal. Indicator lamp for fault will be off and cutter is normal while cut off power and then turn it on for over current condition. Excessive operation may damage cutter as well (e.g. voltage is higher), therefore you must be in accordance with following: 1) Good ventilation ...
A 25 kV, 75 kHz, KICKER FOR MEASUREMENT OF MUON
A 25 kV, 75 kHz, KICKER FOR MEASUREMENT OF MUON

... device with a drain-source (D-S) rating of 1 kV and power rating of 220 W at a case temperature of 100°C. As a result of the relatively long maximum pulse length of previous designs (DC is possible for [7] & [8]) the HV output of the modulator for the TRIUMF designs is coupled directly to the deflec ...
Wiring Cables and Conductors
Wiring Cables and Conductors

... (Note: All the mentioned tables in this course refer to, unless otherwise specified, Low Voltage Electrical Installation Handbook, by Johnny C.F. Wong, Edition 2004) ...
CN0202: 灵活、高精度、低漂移的PLC/DCS模拟输出模块SigmaDSP音频处理器的接口
CN0202: 灵活、高精度、低漂移的PLC/DCS模拟输出模块SigmaDSP音频处理器的接口

... Continued from first page) Circuits from the Lab circuits are intended only for use with Analog Devices products and are the intellectual property of Analog Devices or its licensors. While you may use the Circuits from the Lab circuits in the design of your product, no other license is granted by im ...
< 1 ... 261 262 263 264 265 266 267 268 269 ... 584 >

Ground (electricity)



In electrical engineering, ground or earth is the reference point in an electrical circuit from which voltages are measured, a common return path for electric current, or a direct physical connection to the Earth.Electrical circuits may be connected to ground (earth) for several reasons. In mains powered equipment, exposed metal parts are connected to ground to prevent user contact with dangerous voltage if electrical insulation fails. Connections to ground limit the build-up of static electricity when handling flammable products or electrostatic-sensitive devices. In some telegraph and power transmission circuits, the earth itself can be used as one conductor of the circuit, saving the cost of installing a separate return conductor (see single-wire earth return).For measurement purposes, the Earth serves as a (reasonably) constant potential reference against which other potentials can be measured. An electrical ground system should have an appropriate current-carrying capability to serve as an adequate zero-voltage reference level. In electronic circuit theory, a ""ground"" is usually idealized as an infinite source or sink for charge, which can absorb an unlimited amount of current without changing its potential. Where a real ground connection has a significant resistance, the approximation of zero potential is no longer valid. Stray voltages or earth potential rise effects will occur, which may create noise in signals or if large enough will produce an electric shock hazard.The use of the term ground (or earth) is so common in electrical and electronics applications that circuits in portable electronic devices such as cell phones and media players as well as circuits in vehicles may be spoken of as having a ""ground"" connection without any actual connection to the Earth, despite ""common"" being a more appropriate term for such a connection. This is usually a large conductor attached to one side of the power supply (such as the ""ground plane"" on a printed circuit board) which serves as the common return path for current from many different components in the circuit.