• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
NCV7680-NCV3136EVB NCV7680-NCV3163 Evaluation Board User's Manual
NCV7680-NCV3136EVB NCV7680-NCV3163 Evaluation Board User's Manual

... limitation special, consequential or incidental damages. “Typical” parameters which may be provided in SCILLC data sheets and/or specifications can and do vary in different applications and actual performance may vary over time. All operating parameters, including “Typicals” must be validated for ea ...
Si3402-C - Silicon Labs
Si3402-C - Silicon Labs

... the RJ-45 connector, simplifies system design, and provides significant advantages for reliability and protection. The Si3402 requires only four standard external components (detection resistor, optional classification resistor, load capacitor, and input capacitor) to create a fully IEEE 802.3-compl ...
Feasibility Study of Inductor Coupling in Three- Level Neutral
Feasibility Study of Inductor Coupling in Three- Level Neutral

... point clamped quasi-Z-source inverter (3L NPC qZSI) based DC/AC converter performance is effective and reliable [1]–[4]. Fig. 1 illustrates a general circuit diagram of the 3L NPC qZSI based single-phase DC/AC converter. The main advantages of the converter are continuous input current, input voltag ...
DYNAMO AND REGULATOR Most /2 BMW`s are equiped with a 6
DYNAMO AND REGULATOR Most /2 BMW`s are equiped with a 6

... voltage drops gradually. Thus the setting of the regulator is a compromise. The voltage is too high when there are not much consumers, thus boiling the battery, and it is too low when everyting is switched on, thus starving the battery. The regulator is also sensitive for temperature. The higher the ...
A very high performance self-biased cascode current mirror for
A very high performance self-biased cascode current mirror for

... 0.18 lm CMOS technology, using a single supply voltage of -1 V. For all the proposed circuits, aspect ratios of the transistors (if used) are M6 = 0.18/0.18, M7 and M10 = 10/ 0.18 and for rest of the MOSFETs aspect ratio is equal to 1/0.18. For all the DC analysis, iIN is varied from 0 to 500 lA. Fi ...
N:2-3 / Series and Parallel Circuits
N:2-3 / Series and Parallel Circuits

... •What happens if a light burns out in a parallel circuit? •If there is a break in one branch, current can still move through the other branches. •So if one bulb goes out, the others remain lit. •Switches can be placed along each branch so that individual bulbs can be turned on and off without affect ...
DTD123TK
DTD123TK

... The content specified herein is subject to change for improvement without notice. The content specified herein is for the purpose of introducing ROHM's products (hereinafter "Products"). If you wish to use any such Product, please be sure to refer to the specifications, which can be obtained from RO ...
A 52 Amplifier2.qxp
A 52 Amplifier2.qxp

... Power amplifiers are usually heavier and generate more heat than other components. To avoid damage to the A 51 or other equipment and to reduce risk of fire, you must follow these guidelines: ...
new Am1000E install Manual
new Am1000E install Manual

... turning the transmitter audio gain down a bit, you may need to turn it down to almost off if you are getting to much drive from the 222. Adjust 222 output level and Transmitter level for good sound from a test radio. Be careful about having a radio to close to the transmitter, it can be overloaded. ...
AE04603181184
AE04603181184

... non-critical path until positive slack disappears. This to build the CVS structure. Finally, the simulator calculates the final result. Power of the CVS structure and compares it with the power of the replacement proceeds in reverse order from the end of each path 0) initial single-VDD design. The i ...
PNIMNiPE_nr56
PNIMNiPE_nr56

... torques in asynchronous motors), overload and excessive overheating of the neutral conductor, degradation of network voltage. These negative effects always have economic impacts resulting from the additional costs linked to energy losses, over sizing of equipment or to loss of productivity. There ar ...
FT100-LV Auto Detuned Filter Cap Bank Technical Spec
FT100-LV Auto Detuned Filter Cap Bank Technical Spec

... The Control permit selection of a target power factor, adjustable to any value between 0.90 lagging to leading P.F. Controls continuously sense the P.F. on circuits being and, when the power factor differs from the target setting with programmable switched time operation (close and open contactor). ...
Measuring Micro-amp Inductor Currents in Switched
Measuring Micro-amp Inductor Currents in Switched

... inaccessible places like the human body and large infrastructures like factories, hospitals, and farms. For this, they require an onboard source and a power-conditioning circuit that supply microwatts about a prescribed dc voltage. And since tiny dc batteries store little energy, switched-inductor d ...
TPS54872 数据资料 dataSheet 下载
TPS54872 数据资料 dataSheet 下载

... signals. Noise injected between the two grounds can degrade the performance of the TPS54872, particularly at higher output currents. Ground noise on an analog ground plane can also cause problems with some of the control and bias signals. For these reasons, separate analog and power ground traces ar ...
PSR-SxF/URM/4X1/2X2
PSR-SxF/URM/4X1/2X2

... In the event of an error, replace the device immediately. Repairs, especially if the housing must be opened, may only be carried out by the manufacturer or authorized persons. Otherwise the warranty is invalidated. According to EN 50205, only one N/O contact and one N/C contact may be used as positi ...
Fig. 7-7 - We can`t sign you in
Fig. 7-7 - We can`t sign you in

... the requirements of the US National Electrical Code. The connection between the system and the utility must also meet or exceed the requirements of the US National Electrical Code. 2. Second; the grounding system The grounding system consists of a low-impedance connection between the enclosure and a ...
EE362L, Fall 2006 Isolated Firing Circuit for H
EE362L, Fall 2006 Isolated Firing Circuit for H

... A– and B – can share a power supply and ground . A + and B + must each use separate power supplies and grounds. Do not connect any of these grounds to the ground of the control circuit. ...
D N IAGNOSTIC EWS
D N IAGNOSTIC EWS

... motor stators rated as low as 440 V. In this article I will concentration the effect of the voltage source type of pulse width modulated (PWM) IFDs on stators rated about 2400 V and above. These stators are usually if the “form wound” type. Unlike the situation in low voltage motors, PD is not the o ...
lightning safety guideline: results of an 8 year
lightning safety guideline: results of an 8 year

... 3.2 Downconductors. Downconductor pathways should be installed outside of the structure. Rigid strap is preferred to flexible cable due to inductance advantages. Conductors should not be painted, since this will increase impedance. Gradual bends always should be employed to avoid flashover problems. ...
Code Panel Questions and Answers
Code Panel Questions and Answers

... 10. In Section 310.15.B(4)(a) of the NEC, it indicates "A neutral conductor that carries only the unbalanced current from other conductors of the same circuit shall not be required to be counted when applying the provisions of 310.15(B)(2)(a)". The application in question is a 2 wire singlephase ci ...
2 - Electrical Contractor Network
2 - Electrical Contractor Network

... When performing manual arc welding there is a significant potential for the welder to receive a shock by simultaneously touching the electrode and workpiece. This is due to the fact the electrode is changed while the electrode holder is electrically live. Fuses or earth leakage contact breakers do n ...
Transformers
Transformers

... Transformers have the following major ratings: 1. Apparent power; ...
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE) e-ISSN: 2278-1676,p-ISSN: 2320-3331,
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE) e-ISSN: 2278-1676,p-ISSN: 2320-3331,

... transformers suitable for transmitting high current and high frequency pulses are may be used for magnetic isolation. In medium voltage applications pulses are usually transmitted to the gate by a ferrite core placed around a single wire carrying the low voltage side current. There is isolation mate ...
ORIGINATION FORM  …
ORIGINATION FORM …

Application Notes Ohm’s Law
Application Notes Ohm’s Law

... Clearance: The shortest distance through space between two live parts, between live parts and supports or other objects, or between any live part and grounded part. Conduction: The transmission of heat or electricity through, or by means of, a conductor. Conductor: A body so constructed from conduct ...
< 1 ... 232 233 234 235 236 237 238 239 240 ... 584 >

Ground (electricity)



In electrical engineering, ground or earth is the reference point in an electrical circuit from which voltages are measured, a common return path for electric current, or a direct physical connection to the Earth.Electrical circuits may be connected to ground (earth) for several reasons. In mains powered equipment, exposed metal parts are connected to ground to prevent user contact with dangerous voltage if electrical insulation fails. Connections to ground limit the build-up of static electricity when handling flammable products or electrostatic-sensitive devices. In some telegraph and power transmission circuits, the earth itself can be used as one conductor of the circuit, saving the cost of installing a separate return conductor (see single-wire earth return).For measurement purposes, the Earth serves as a (reasonably) constant potential reference against which other potentials can be measured. An electrical ground system should have an appropriate current-carrying capability to serve as an adequate zero-voltage reference level. In electronic circuit theory, a ""ground"" is usually idealized as an infinite source or sink for charge, which can absorb an unlimited amount of current without changing its potential. Where a real ground connection has a significant resistance, the approximation of zero potential is no longer valid. Stray voltages or earth potential rise effects will occur, which may create noise in signals or if large enough will produce an electric shock hazard.The use of the term ground (or earth) is so common in electrical and electronics applications that circuits in portable electronic devices such as cell phones and media players as well as circuits in vehicles may be spoken of as having a ""ground"" connection without any actual connection to the Earth, despite ""common"" being a more appropriate term for such a connection. This is usually a large conductor attached to one side of the power supply (such as the ""ground plane"" on a printed circuit board) which serves as the common return path for current from many different components in the circuit.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report