• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Protection of Busbars and Lines
Protection of Busbars and Lines

UCC2961 数据资料 dataSheet 下载
UCC2961 数据资料 dataSheet 下载

... The UCC3961 provides all the circuitry required on the primary side of a secondary-side controlled power supply. It features a free running 60-kHz to 360-kHz oscillator which is synchronizable to the secondary-side PWM signal and also has the ability to accept start/stop PWM commands from the isolat ...
Lecture-07
Lecture-07

... The armature winding can broadly be classified as concentrated and distributed winding. In case of a concentrated winding, all the conductors / pole is housed in one slot. Since the conductors / slot is more, quantity of insulation in the slot is more, heat dissipation is less, temperature rise is m ...
Wall Presentation
Wall Presentation

... power density and reliability for their customer, a global Tier 1 provider. With ISO standards driving their organization, quality and reliability were paramount. We had to make sure that their monitored hot standby equipment for failover was compliant with their service level guarantees. SOLUTION W ...
Powercut 900
Powercut 900

... Set the switch (wall socket or similar) to on. Check that the compressor is connected to the power source. Set the mains voltage switch to I (On). Flip the toggle switch upwards to gas test mode (GAS TEST). Set the pressure regulator to 5.5 bar (80 psi). 5. Set the toggle switch to normal mode (CENT ...
INSTALLATION INSTRUCTIONS FOR SYMCOM`S MOTORSAVER
INSTALLATION INSTRUCTIONS FOR SYMCOM`S MOTORSAVER

... Measure the three line-to-line voltages. Calculate the average of the three voltages. If the average is outside of ±7% of the nominal voltage as set by LINE VOLTAGE ADJUST, then the Model 460 is functioning properly. If the voltage is within the reset window, try pressing the manual reset button. If ...
IR3314761483
IR3314761483

... switching power supplies with bridge rectifiers. ...
Familiarisation of Electronic Components and
Familiarisation of Electronic Components and

... An electrolytic capacitor consists of an aluminium-foil electrode which has an aluminiumoxide film covering on one side. The aluminium plate serves as the positive plate and the oxide as the dielectric. The oxide is in contact with a paper or gauze saturated with an electrolyte. The electrolyte form ...
Chapter 11
Chapter 11

... – however, it is often useful to know the average magnitude of the waveform independent of its polarity  we can think of this as the average value over half a cycle…  … or as the average value of the rectified signal ...
FSL156MRIN Green-Mode Fairchild Power Switch (FPS™) FSL156MRIN — Green-Mode Fair
FSL156MRIN Green-Mode Fairchild Power Switch (FPS™) FSL156MRIN — Green-Mode Fair

Fault Identification and Islanding in DC Grid Connected PV System
Fault Identification and Islanding in DC Grid Connected PV System

... create large backed current and very high Earth-fault current. Without any sensor, these faults are identified, when the sign of the monitored primary grid current is changed [21]. 2) Bridging fault When low-resistance connection recognized between two points of different potential in string of modu ...
technical information
technical information

... VNN. 7. D1 is the flywheel diode for the VN10 buck converter and prevents VN10SW (pin 5) from going more than one diode drop below VNN. In general, to enable placement as close to the TA2022, and minimize PCB parasitics, the capacitors listed above are surface mount and located on the “solder” side ...
A lamp rated at 12 V 60 W is connected to the secondary coil
A lamp rated at 12 V 60 W is connected to the secondary coil

... or I2R loss or voltage drop (across cable) B1 lower current lowers loss of heat/energy/power or reduces voltage drop B1 ac can be transformed (to lower transmission current) B1 ...
parallel
parallel

... • Provides potential difference for circuit • Electrons will flow from high voltage to low voltage in circuit ...
Power Quality - Schneider Electric
Power Quality - Schneider Electric

... Corrective maintenance Even where best practice is observed (singleline diagram, choice of protective devices and neutral point connection, application of appropriate solutions) right from the design phase, malfunctions may occur during operation: c Disturbances may have been ignored or under-estima ...
Panamax PM Component Family
Panamax PM Component Family

... Circuit Breaker: Automatically opens when the current load is greater than 15 Amps. Ground Lug: Provides a common grounding point for equipment with separate ground leads. ...
Solutionto QuestionBank
Solutionto QuestionBank

Surge Protective Devices
Surge Protective Devices

... US and Canadian UL® Recognized as a Type 2 (or 1 with optional suffix in catalog number) SPD Component Assembly to UL 1449 3rd Edition and UL 1283 5th Edition. Complies with requirements of NEC® Article 285 and CSA C22.2 No. 8-M1986 as appropriate. Complies with UL 96A 12th Edition Master Label requ ...
Coupled Inductor Based H6 Transformer less Full Bridge Inverter
Coupled Inductor Based H6 Transformer less Full Bridge Inverter

... comparing with other renewable energy sources. Therefore, the grid-tied inverters need to be watchfully planned for achieving the purposes of high competence, low rate, small dimension, and small weight, especially in the low-power single-phase systems (less than 5 kW). From the safety point of view ...
Spark Gap Surge Protectors For Lv Mains
Spark Gap Surge Protectors For Lv Mains

... Spark gap surge diverters must be chosen with an AC fault current rating equal to or greater than the potential fault current of the installation. If not there is no guarantee that the arc will be extinguished at the next zero crossing. For example many of the German domestic types have fault curre ...
Refractory Neuron Circuits
Refractory Neuron Circuits

... potential. Sodium and potassium conductances are usually present at axon-hillock locations in biological neurons, and one can generate action potentials by injecting current at these locations. The circuit, therefore, bears some similarity to biological axon-hillock circuits. The second of our neuro ...
Advances in Natural and Applied Sciences
Advances in Natural and Applied Sciences

... of the system is limited & if there is any further increase in power transfer, there occurs a very rapid decrease in voltage magnitude. Hence, before reaching critical point, system can be saved from voltage collapse by implementation of reactive power support. This support can be provided by FACTS ...
Section 3 Chapter 1
Section 3 Chapter 1

... We wish to be able to talk about, solve for, and indicate clearly the directions for both current and voltage. For current, we wish to be clear about which direction positive charges are moving. For voltage, we wish to be clear about which direction would result in a positive charge losing energy. T ...
A Draft Standard Glossary of Power Quality - Working Group
A Draft Standard Glossary of Power Quality - Working Group

... A voltage that appears between current-carrying conductors and ground. Source: [2] The noise voltage that appears equally and in phase from each current-carrying conductor to ground. Source: [4] Consider the case of a power circuit consisting of one or more phases, a neutral and a ground wire. It is ...
V1.0 CDI PSU Module - Rae
V1.0 CDI PSU Module - Rae

< 1 ... 203 204 205 206 207 208 209 210 211 ... 584 >

Ground (electricity)



In electrical engineering, ground or earth is the reference point in an electrical circuit from which voltages are measured, a common return path for electric current, or a direct physical connection to the Earth.Electrical circuits may be connected to ground (earth) for several reasons. In mains powered equipment, exposed metal parts are connected to ground to prevent user contact with dangerous voltage if electrical insulation fails. Connections to ground limit the build-up of static electricity when handling flammable products or electrostatic-sensitive devices. In some telegraph and power transmission circuits, the earth itself can be used as one conductor of the circuit, saving the cost of installing a separate return conductor (see single-wire earth return).For measurement purposes, the Earth serves as a (reasonably) constant potential reference against which other potentials can be measured. An electrical ground system should have an appropriate current-carrying capability to serve as an adequate zero-voltage reference level. In electronic circuit theory, a ""ground"" is usually idealized as an infinite source or sink for charge, which can absorb an unlimited amount of current without changing its potential. Where a real ground connection has a significant resistance, the approximation of zero potential is no longer valid. Stray voltages or earth potential rise effects will occur, which may create noise in signals or if large enough will produce an electric shock hazard.The use of the term ground (or earth) is so common in electrical and electronics applications that circuits in portable electronic devices such as cell phones and media players as well as circuits in vehicles may be spoken of as having a ""ground"" connection without any actual connection to the Earth, despite ""common"" being a more appropriate term for such a connection. This is usually a large conductor attached to one side of the power supply (such as the ""ground plane"" on a printed circuit board) which serves as the common return path for current from many different components in the circuit.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report