A New Algorithm for Digital Low-impedance Protection of Busbars
... I. INTRODUCTION Protection of power system busbars is one of the most critical relaying applications. Busbars are areas in the power systems where the level of fault currents may be very high. Despite of that some of the circuits connected to the bus may have their Current Transformers (CTs) insuffi ...
... I. INTRODUCTION Protection of power system busbars is one of the most critical relaying applications. Busbars are areas in the power systems where the level of fault currents may be very high. Despite of that some of the circuits connected to the bus may have their Current Transformers (CTs) insuffi ...
CHAPTER 1: Introduction to Computer Parts and
... Protect the Equipment Against Static Electricity or ESD • Rule 1: When passing a circuit board or other component to another person, ground yourself and touch the other person before you pass it • Rule 2: Leave components inside antistatic bags until ready to use them • Rule 3: Work on hard floors, ...
... Protect the Equipment Against Static Electricity or ESD • Rule 1: When passing a circuit board or other component to another person, ground yourself and touch the other person before you pass it • Rule 2: Leave components inside antistatic bags until ready to use them • Rule 3: Work on hard floors, ...
Wiring Schematics and Circuit Testing
... Wiring Schematics and Circuit Testing FIGURE 28.25 A cross-sectional view of a typical four terminal relay. Current flowing through the coil ...
... Wiring Schematics and Circuit Testing FIGURE 28.25 A cross-sectional view of a typical four terminal relay. Current flowing through the coil ...
BD9A101MUV-LB
... Power supply terminals for the switching regulator. These terminals supply power to the output stage of the switching regulator. Connecting a 10µF ceramic capacitor is recommended. Ground terminals for the output stage of the switching regulator. Ground terminal for the control circuit. An inverting ...
... Power supply terminals for the switching regulator. These terminals supply power to the output stage of the switching regulator. Connecting a 10µF ceramic capacitor is recommended. Ground terminals for the output stage of the switching regulator. Ground terminal for the control circuit. An inverting ...
Fault Location Of Overhead Transmission Line.pdf
... The fault location is then determined by timing analysis of the travelling wave. As the faulted signal obtained at the end of the transmission line is highly mingled with noise, some modern signal processing techniques, such as the wavelet are used for fault location. In the traveling-wave based app ...
... The fault location is then determined by timing analysis of the travelling wave. As the faulted signal obtained at the end of the transmission line is highly mingled with noise, some modern signal processing techniques, such as the wavelet are used for fault location. In the traveling-wave based app ...
BD9B300MUV
... BD9B300MUV is a synchronous buck switching regulator with built-in low on-resistance power MOSFETs. This IC, which is capable of providing current up to 3A, features fast transient response by employing constant on-time control system. It offers high oscillating frequency at low inductance. With its ...
... BD9B300MUV is a synchronous buck switching regulator with built-in low on-resistance power MOSFETs. This IC, which is capable of providing current up to 3A, features fast transient response by employing constant on-time control system. It offers high oscillating frequency at low inductance. With its ...
have been applied in industrial ... aircrafts and electric vehicle applications with more electrically
... operations to increase the reliability of power electronic systems [27]. In the technical literature, two main fault tolerant solutions for the MC under open-switch fault have been studied. The first one is modifying and refactoring the MC topology by adding additional hardware to the converter [18] ...
... operations to increase the reliability of power electronic systems [27]. In the technical literature, two main fault tolerant solutions for the MC under open-switch fault have been studied. The first one is modifying and refactoring the MC topology by adding additional hardware to the converter [18] ...
Leadership in circuit protection DC Combiner box and AC solutions
... Eaton can offer a comprehensive range of products for safe, reliable and sustainable PV systems within residential, commercial and utility sectors. Drawing on a hundred years of design and expertise the Bussmann by Eaton combiner box can be configured as a simple 2 string unit for residential systems ...
... Eaton can offer a comprehensive range of products for safe, reliable and sustainable PV systems within residential, commercial and utility sectors. Drawing on a hundred years of design and expertise the Bussmann by Eaton combiner box can be configured as a simple 2 string unit for residential systems ...
AP133
... A1μF ceramic capacitor is recommended to connect between VIN and GND pins to decouple input power supply glitch and noise. The amount of the capacitance may be increased without limit. This input capacitor must be located as close as possible to the device to assure input stability and less noise. F ...
... A1μF ceramic capacitor is recommended to connect between VIN and GND pins to decouple input power supply glitch and noise. The amount of the capacitance may be increased without limit. This input capacitor must be located as close as possible to the device to assure input stability and less noise. F ...
Power analysis
... The initial process consists of attempting to understand how the electricity is consumed, irrespective of whether or not this is the only source of energy. What are the largest functions? How is the electricity used? If it is known exactly what the energy is used for, it may be possible to act at th ...
... The initial process consists of attempting to understand how the electricity is consumed, irrespective of whether or not this is the only source of energy. What are the largest functions? How is the electricity used? If it is known exactly what the energy is used for, it may be possible to act at th ...
COH Interference 7-10
... These currents are continually varying in amplitude and/or continually, changing their electrolytic paths. • Light rail systems. • DC mining activities. • DC welding on the pipeline. ...
... These currents are continually varying in amplitude and/or continually, changing their electrolytic paths. • Light rail systems. • DC mining activities. • DC welding on the pipeline. ...
1977 - HP Archive
... When troubleshooting circuits built with discrete components (resistors, capacitors, transistors, etc.), the task is one of verifying relatively simple characteristics such as resistance, capacitance, or bias voltages of components. While the function of the total circuit may be quite complex, each ...
... When troubleshooting circuits built with discrete components (resistors, capacitors, transistors, etc.), the task is one of verifying relatively simple characteristics such as resistance, capacitance, or bias voltages of components. While the function of the total circuit may be quite complex, each ...
LTC2920-1/LTC2920-2 - Single/Dual Power Supply Margining
... these resistors are usually calculated by the design engineer using two different equations supplied by the manufacturer. There is usually one equation for trimming the voltage up, and another equation for trimming the voltage down. In most cases, the power supply module is treated like a “black box ...
... these resistors are usually calculated by the design engineer using two different equations supplied by the manufacturer. There is usually one equation for trimming the voltage up, and another equation for trimming the voltage down. In most cases, the power supply module is treated like a “black box ...
Mitsubishi Heavy Industries
... course of aluminum coating about the sample equipped with aluminum coating. Although there were some points that aluminum showed dissolution partially, there was no penetration of FRP. FRP damaged area of two kinds of FRP samples that do not carry out aluminum coating on the other hand. In FRP of 45 ...
... course of aluminum coating about the sample equipped with aluminum coating. Although there were some points that aluminum showed dissolution partially, there was no penetration of FRP. FRP damaged area of two kinds of FRP samples that do not carry out aluminum coating on the other hand. In FRP of 45 ...
Atmel AT42QT1011 Single-key QTouch Touch Sensor IC Features
... Electrode Drive For optimum noise immunity, the electrode should only be connected to SNSK. In all cases the rule Cs >> Cx must be observed for proper operation; a typical load capacitance (Cx) ranges from 5 – 20 pF while Cs is usually about 2 – 50 nF. Increasing amounts of Cx destroy gain, therefor ...
... Electrode Drive For optimum noise immunity, the electrode should only be connected to SNSK. In all cases the rule Cs >> Cx must be observed for proper operation; a typical load capacitance (Cx) ranges from 5 – 20 pF while Cs is usually about 2 – 50 nF. Increasing amounts of Cx destroy gain, therefor ...
Aalborg Universitet Methods to Minimize Zero-Missing Phenomenon W.; Knardrupgård, M. R.
... As explained before, the DC component is zero for a shunt reactor energized at voltage peak. For direct connected shunt reactors, the cable and shunt reactor are energized simultaneously, and it is not possible to use this method because of switching overvoltage. But if the shunt reactors are connec ...
... As explained before, the DC component is zero for a shunt reactor energized at voltage peak. For direct connected shunt reactors, the cable and shunt reactor are energized simultaneously, and it is not possible to use this method because of switching overvoltage. But if the shunt reactors are connec ...
Power System Analysis Prof. A. K. Sinha Department of Electrical
... are much more common than the three-phase to ground faults are basically asymmetrical faults. Because, they create asymmetry in the current and voltage in the three-phases of the system. Whereas a three phase or a three phase to ground fault is basically a symmetrical fault. Because they are in cas ...
... are much more common than the three-phase to ground faults are basically asymmetrical faults. Because, they create asymmetry in the current and voltage in the three-phases of the system. Whereas a three phase or a three phase to ground fault is basically a symmetrical fault. Because they are in cas ...
AN3089
... increase of the duration of the no-load operation, therefore decreasing the power dissipation and the stress of the power components. This sequence is repeated until the short is removed, after that normal operation of the converter is automatically resumed. A second protection, dedicated to protect ...
... increase of the duration of the no-load operation, therefore decreasing the power dissipation and the stress of the power components. This sequence is repeated until the short is removed, after that normal operation of the converter is automatically resumed. A second protection, dedicated to protect ...
excitation systems
... these functions depending on the specific application and the type of exciter control functions regulate specific quantities at the desired level limiting functions prevent certain quantities from exceeding set limits if any of the limiters fail, then protective functions remove appropriate co ...
... these functions depending on the specific application and the type of exciter control functions regulate specific quantities at the desired level limiting functions prevent certain quantities from exceeding set limits if any of the limiters fail, then protective functions remove appropriate co ...
Ground (electricity)
In electrical engineering, ground or earth is the reference point in an electrical circuit from which voltages are measured, a common return path for electric current, or a direct physical connection to the Earth.Electrical circuits may be connected to ground (earth) for several reasons. In mains powered equipment, exposed metal parts are connected to ground to prevent user contact with dangerous voltage if electrical insulation fails. Connections to ground limit the build-up of static electricity when handling flammable products or electrostatic-sensitive devices. In some telegraph and power transmission circuits, the earth itself can be used as one conductor of the circuit, saving the cost of installing a separate return conductor (see single-wire earth return).For measurement purposes, the Earth serves as a (reasonably) constant potential reference against which other potentials can be measured. An electrical ground system should have an appropriate current-carrying capability to serve as an adequate zero-voltage reference level. In electronic circuit theory, a ""ground"" is usually idealized as an infinite source or sink for charge, which can absorb an unlimited amount of current without changing its potential. Where a real ground connection has a significant resistance, the approximation of zero potential is no longer valid. Stray voltages or earth potential rise effects will occur, which may create noise in signals or if large enough will produce an electric shock hazard.The use of the term ground (or earth) is so common in electrical and electronics applications that circuits in portable electronic devices such as cell phones and media players as well as circuits in vehicles may be spoken of as having a ""ground"" connection without any actual connection to the Earth, despite ""common"" being a more appropriate term for such a connection. This is usually a large conductor attached to one side of the power supply (such as the ""ground plane"" on a printed circuit board) which serves as the common return path for current from many different components in the circuit.