
AD9850 Data Sheet
... phase-programmable, analog output sine wave. This sine wave can be used directly as a frequency source or converted to a square wave for agile-clock generator applications. The AD9850’s innovative high speed DDS core provides a 32-bit frequency tuning word, which results in an output tuning resoluti ...
... phase-programmable, analog output sine wave. This sine wave can be used directly as a frequency source or converted to a square wave for agile-clock generator applications. The AD9850’s innovative high speed DDS core provides a 32-bit frequency tuning word, which results in an output tuning resoluti ...
Software Design and Hardware Realisation of Single Phase
... Abstract- The electricity produced at power stations has a frequency of 50 Hz which is not always applicable for some electrical equipments. Some electrical devices need variable frequency ranging from one tenth to one third of supply frequency. Some examples are induction motors used in AC traction ...
... Abstract- The electricity produced at power stations has a frequency of 50 Hz which is not always applicable for some electrical equipments. Some electrical devices need variable frequency ranging from one tenth to one third of supply frequency. Some examples are induction motors used in AC traction ...
MAX2059 - Maxim Integrated
... EDGE, cdma2000®, WCDMA/UMTS, and TD-SCDMA base stations. The MAX2059 yields a high level of component integration, which includes two 5-bit digital attenuators, a two-stage driver amplifier, a loopback mixer, and a serial interface to control the attenuators. The MAX2059 is pin compatible with the M ...
... EDGE, cdma2000®, WCDMA/UMTS, and TD-SCDMA base stations. The MAX2059 yields a high level of component integration, which includes two 5-bit digital attenuators, a two-stage driver amplifier, a loopback mixer, and a serial interface to control the attenuators. The MAX2059 is pin compatible with the M ...
17511 Sample Question Paper
... b) A three phase 16 pole alternator has a star connected winding with 144 slots and 10 conductors per slot. The flux per pole is 0.03 wb sinusoidally distributed and the speed of prime mover is 375 rpm. Find the frequency, phase and line emfs assuming full pitched coils. f) A motor is to be operated ...
... b) A three phase 16 pole alternator has a star connected winding with 144 slots and 10 conductors per slot. The flux per pole is 0.03 wb sinusoidally distributed and the speed of prime mover is 375 rpm. Find the frequency, phase and line emfs assuming full pitched coils. f) A motor is to be operated ...
Inverter Power Stage Connected with PV-Grid
... using bidirectional devices [8]. Hierarchical control for DC and AC microgrids proposed [9]. A reconfiguration strategy proposed for PV systems to achieve maximum power generation from non-uniformly aged PV module [10]. Grid with PV inverters, owing to the growth of world’s power demand, the necessi ...
... using bidirectional devices [8]. Hierarchical control for DC and AC microgrids proposed [9]. A reconfiguration strategy proposed for PV systems to achieve maximum power generation from non-uniformly aged PV module [10]. Grid with PV inverters, owing to the growth of world’s power demand, the necessi ...
Power Electronics - Dr. Imtiaz Hussain
... • Capacitors and magnetic devices are important elements of switching converters, because ideally they do not consume power. • It is the resistive element, as well as the linear-mode semiconductor device, that is avoided. • Semiconductor in switch mode however dissipate comparatively low power in ei ...
... • Capacitors and magnetic devices are important elements of switching converters, because ideally they do not consume power. • It is the resistive element, as well as the linear-mode semiconductor device, that is avoided. • Semiconductor in switch mode however dissipate comparatively low power in ei ...
Switched-mode power supply
... A linear regulator provides the desired output voltage by dissipating excess power in ohmic losses (e.g., in a resistor or in the collector–emitter region of a pass transistor in its active mode). A linear regulator regulates either output voltage or current by dissipating the excess electric power ...
... A linear regulator provides the desired output voltage by dissipating excess power in ohmic losses (e.g., in a resistor or in the collector–emitter region of a pass transistor in its active mode). A linear regulator regulates either output voltage or current by dissipating the excess electric power ...
General class license
... Authors class Requirements when he is teaching a General license class. 1. It is required that students each have a color printed copy of this syllabus to study from and that they bring to class. The instructor will be teaching from the syllabus during the class. All the possible questions that cou ...
... Authors class Requirements when he is teaching a General license class. 1. It is required that students each have a color printed copy of this syllabus to study from and that they bring to class. The instructor will be teaching from the syllabus during the class. All the possible questions that cou ...
LM22670,LM22671,LM22672,LM22673,LM22674, LM22675,LM22676,LM22677,LM22678,LM22679, LM25005,LM3578A,LM5000,LM5001,LM5002,
... the R1 feedback resistor should stay in parallel with R1 and not be modified by the introduction of the 20Ω resistor. A sound mechanical measurement structure is shown in Figure 2. The feedback path is broken on the PCB and a 20Ω resistor is soldered on the PCB. Some of evaluation boards may already ...
... the R1 feedback resistor should stay in parallel with R1 and not be modified by the introduction of the 20Ω resistor. A sound mechanical measurement structure is shown in Figure 2. The feedback path is broken on the PCB and a 20Ω resistor is soldered on the PCB. Some of evaluation boards may already ...
Aalborg Universitet Coordinated Power Control Strategy based on Primary-Frequency-Signaling for Islanded Microgrids
... loads according to power regulation capability of units. The conventional way for the system management to achieve coordinated control is supervisory control with communication link [6-7]. This algorithm utilizes a higher level controller to manage the power flow of each unit using physical communic ...
... loads according to power regulation capability of units. The conventional way for the system management to achieve coordinated control is supervisory control with communication link [6-7]. This algorithm utilizes a higher level controller to manage the power flow of each unit using physical communic ...
0.18µm PHASE / FREQUENCY DETECTOR AND CHARGE PUMP
... DVB-H operating frequency in US is between 1.67 and 1.675GHz, while for the European operating frequency is between 470 and 867MHz. Since DVB-H originally derived from DVB-T, it has all its standards with some new additions to make it suitable for handheld devices. One of these additions is the time ...
... DVB-H operating frequency in US is between 1.67 and 1.675GHz, while for the European operating frequency is between 470 and 867MHz. Since DVB-H originally derived from DVB-T, it has all its standards with some new additions to make it suitable for handheld devices. One of these additions is the time ...
Utility frequency
The utility frequency, (power) line frequency (American English) or mains frequency (British English) is the frequency of the oscillations of alternating current (AC) in an electric power grid transmitted from a power plant to the end-user. In large parts of the world this is 50 Hz, although in the Americas and parts of Asia it is typically 60 Hz. Current usage by country or region is given in the list of mains power around the world.During the development of commercial electric power systems in the late 19th and early 20th centuries, many different frequencies (and voltages) had been used. Large investment in equipment at one frequency made standardization a slow process. However, as of the turn of the 21st century, places that now use the 50 Hz frequency tend to use 220–240 V, and those that now use 60 Hz tend to use 100–127 V. Both frequencies coexist today (Japan uses both) with no great technical reason to prefer one over the other and no apparent desire for complete worldwide standardization.Unless specified by the manufacturer to operate on both 50 and 60 Hz, appliances may not operate efficiently or even safely if used on anything other than the intended frequency.