
MAX7060 280MHz to 450MHz Programmable ASK/FSK Transmitter EVALUATION KIT AVAILABLE
... coded for FSK can be maintained while still satisfying regulatory emission-bandwidth standards. The full set of configuration functions are handled by an on-chip serial peripheral interface (SPI). There is also a manual mode where a limited number of settings can be made directly through selected pi ...
... coded for FSK can be maintained while still satisfying regulatory emission-bandwidth standards. The full set of configuration functions are handled by an on-chip serial peripheral interface (SPI). There is also a manual mode where a limited number of settings can be made directly through selected pi ...
TI2332233228
... But satisfying these rules for the three buses makes the modulation very complicated and it can be shown that under some circumstances for higher number of levels it is not possible to comply with the rules. However, another configuration is possible which does not have the aforementioned problems. I ...
... But satisfying these rules for the three buses makes the modulation very complicated and it can be shown that under some circumstances for higher number of levels it is not possible to comply with the rules. However, another configuration is possible which does not have the aforementioned problems. I ...
i) Synchronous Machines
... electrical power, called synchronous generators or alternators. They are usually large machines generating electrical power at hydro, nuclear, or thermal power stations. Synchronous motors are built in large units compare to induction motors (Induction motors are cheaper for smaller ratings) and ...
... electrical power, called synchronous generators or alternators. They are usually large machines generating electrical power at hydro, nuclear, or thermal power stations. Synchronous motors are built in large units compare to induction motors (Induction motors are cheaper for smaller ratings) and ...
MAX9989/MAX9990 +14dBm to +20dBm LO Buffers with ±1dB Variation General Description
... Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Expo ...
... Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Expo ...
UPS Sentinel XR PLUS 5-10kVA
... reliable current (double conversion on-line technology, VFI compliant with EN62040-3 specifications) with filters to suppress atmospheric interference • Advanced diagnostics: status, measurements and alarms available on the custom LCD display • Very low noise level (<40dBA): for installation in any ...
... reliable current (double conversion on-line technology, VFI compliant with EN62040-3 specifications) with filters to suppress atmospheric interference • Advanced diagnostics: status, measurements and alarms available on the custom LCD display • Very low noise level (<40dBA): for installation in any ...
ADA4850-1
... of the amplifier can swing within 80 mV of either supply rail. With its combination of low price, excellent differential gain (0.12%), differential phase (0.09°), and 0.1 dB flatness out to 14 MHz, these amplifiers are ideal for video applications. ...
... of the amplifier can swing within 80 mV of either supply rail. With its combination of low price, excellent differential gain (0.12%), differential phase (0.09°), and 0.1 dB flatness out to 14 MHz, these amplifiers are ideal for video applications. ...
Category 3 Parallel Operating
... (Project side) of the power transformer, but may instead be connected on the secondary (Utility side). VT’s are required on the secondary of the power transformer if a 59N is required for an ungrounded secondary connection. IEEE std 1547 requirements for voltage and frequency must be met at the PCC. ...
... (Project side) of the power transformer, but may instead be connected on the secondary (Utility side). VT’s are required on the secondary of the power transformer if a 59N is required for an ungrounded secondary connection. IEEE std 1547 requirements for voltage and frequency must be met at the PCC. ...
The most common errors with the digital units are indicated with
... Heater problems? If your digital system is not heating or is only heating to 95-99 degrees, then there is probably a heater or snap disc problem. Open the front panel and disconnect the long black interconnect. Then measure the red wires for a reading of 15-16 ohms. If the measurement is open, then ...
... Heater problems? If your digital system is not heating or is only heating to 95-99 degrees, then there is probably a heater or snap disc problem. Open the front panel and disconnect the long black interconnect. Then measure the red wires for a reading of 15-16 ohms. If the measurement is open, then ...
Differential PECL Series
... 'B package' with pads long enough to accept the smaller 5 x 7mm device. This permits the best option for alternate sources of device. Pletronics also recommends connecting Pin 1 and Pin 2 together on the models with Q & QN OUT on pins 4 & 5. This allows having E/D on either pin 1 or pin 2. ...
... 'B package' with pads long enough to accept the smaller 5 x 7mm device. This permits the best option for alternate sources of device. Pletronics also recommends connecting Pin 1 and Pin 2 together on the models with Q & QN OUT on pins 4 & 5. This allows having E/D on either pin 1 or pin 2. ...
1 - University of Toronto
... (ii) the driven current amplitude is maximum, Imax= V0Q X C0 . The two observations can be considered to be the consequence of the fact that at resonance the loop impedance is pure resistance. It should be mentioned that although in the circuit considered the response current amplitude is maximum at ...
... (ii) the driven current amplitude is maximum, Imax= V0Q X C0 . The two observations can be considered to be the consequence of the fact that at resonance the loop impedance is pure resistance. It should be mentioned that although in the circuit considered the response current amplitude is maximum at ...
1 - Electrical and Computer Engineering
... frequency, DC to DC resonant converter. The goal of the design is to produce an extremely efficient, small, light weight, and cost effective DC to DC converter. These are some of the properties that are made possible by using a ZVT resonant type converter. The converter built in this project has 4 m ...
... frequency, DC to DC resonant converter. The goal of the design is to produce an extremely efficient, small, light weight, and cost effective DC to DC converter. These are some of the properties that are made possible by using a ZVT resonant type converter. The converter built in this project has 4 m ...
Utility frequency
The utility frequency, (power) line frequency (American English) or mains frequency (British English) is the frequency of the oscillations of alternating current (AC) in an electric power grid transmitted from a power plant to the end-user. In large parts of the world this is 50 Hz, although in the Americas and parts of Asia it is typically 60 Hz. Current usage by country or region is given in the list of mains power around the world.During the development of commercial electric power systems in the late 19th and early 20th centuries, many different frequencies (and voltages) had been used. Large investment in equipment at one frequency made standardization a slow process. However, as of the turn of the 21st century, places that now use the 50 Hz frequency tend to use 220–240 V, and those that now use 60 Hz tend to use 100–127 V. Both frequencies coexist today (Japan uses both) with no great technical reason to prefer one over the other and no apparent desire for complete worldwide standardization.Unless specified by the manufacturer to operate on both 50 and 60 Hz, appliances may not operate efficiently or even safely if used on anything other than the intended frequency.