SurePower QL10513 13.0kW and 3.5kW, 13.56
... The SurePower® platform of RF plasma generators is the most advanced class of 13.56 MHz generators commercially available. The SurePower® architecture incorporates state-of-the-art RF topologies, patented intrinsic power amplifier protection, improved design margins, and embedded V-I probe sensors ...
... The SurePower® platform of RF plasma generators is the most advanced class of 13.56 MHz generators commercially available. The SurePower® architecture incorporates state-of-the-art RF topologies, patented intrinsic power amplifier protection, improved design margins, and embedded V-I probe sensors ...
UMJ-910-D14-G VOLTAGE CONTROLLED OSCILLATOR FOR IF CONVERSION Features
... Exceeding any one or a combination of the Absolute Maximum Rating conditions may cause permanent damage to the device. Extended application of Absolute Maximum Rating conditions to the device may reduce device reliability. Specified typical performance or functional operation of the device under Abs ...
... Exceeding any one or a combination of the Absolute Maximum Rating conditions may cause permanent damage to the device. Extended application of Absolute Maximum Rating conditions to the device may reduce device reliability. Specified typical performance or functional operation of the device under Abs ...
James McGinley - EE3311 B05
... a frequency of 100 kHz and amplitude of 1 V peak-to-peak. The free running frequency of the PLL was also adjusted by changing the variable resistor to attain a free running frequency of 100 kHz. We used the two channels of the oscilloscope to view both the input signal and the output of the VCO. Usi ...
... a frequency of 100 kHz and amplitude of 1 V peak-to-peak. The free running frequency of the PLL was also adjusted by changing the variable resistor to attain a free running frequency of 100 kHz. We used the two channels of the oscilloscope to view both the input signal and the output of the VCO. Usi ...
Meijer'I,
... pulse is known for a certain measuring circuit. For 380 kV power cables it was shown that an artificial pulse of 1 V represents 10 pC of PD magnitude [4]. Now, injection of these voltages can be used to test the sensitivity of the on-site measuring circuit by the step 3. 3) Sensitivity check of the ...
... pulse is known for a certain measuring circuit. For 380 kV power cables it was shown that an artificial pulse of 1 V represents 10 pC of PD magnitude [4]. Now, injection of these voltages can be used to test the sensitivity of the on-site measuring circuit by the step 3. 3) Sensitivity check of the ...
PowerPoint 演示文稿
... • so for two machines to operate together their voltages must be changing at the same rate or frequency must be reaching their maximum (or any other value) together. ...
... • so for two machines to operate together their voltages must be changing at the same rate or frequency must be reaching their maximum (or any other value) together. ...
Main characteristics of microprocessors (modern) - G
... • 8086 and 8088. In etih processors to perform a single command takes about 12 cycles. • 286 and 386. These processors have reduced the time to execute commands about 4.5 clock cycles. • Processor 486 and bolshaya of the Intel-compatible processors fourth generation, such as the AMD 5x86, reduce thi ...
... • 8086 and 8088. In etih processors to perform a single command takes about 12 cycles. • 286 and 386. These processors have reduced the time to execute commands about 4.5 clock cycles. • Processor 486 and bolshaya of the Intel-compatible processors fourth generation, such as the AMD 5x86, reduce thi ...
Document
... Proposal to minimize transient oscillations proposed droop control is obtained by changing the frequency setting of incoming generator from the PC frequency to the droop frequency with a time constant of governor characteristic ...
... Proposal to minimize transient oscillations proposed droop control is obtained by changing the frequency setting of incoming generator from the PC frequency to the droop frequency with a time constant of governor characteristic ...
Software de análisis de potencia
... entire cycle at the switching device Min, Max and average values computed for trend data on switching loss over time in a dynamic load situation HiPower Finder feature analyzes pinpoints areas of instantaneous power dissipation ...
... entire cycle at the switching device Min, Max and average values computed for trend data on switching loss over time in a dynamic load situation HiPower Finder feature analyzes pinpoints areas of instantaneous power dissipation ...
Aalborg Universitet Single-Phase Shunt Active Power Filters Under Adverse Grid Conditions
... classified into time-domain and frequency domain techniques. The digital Fourier transform (DFT), fast Fourier transform (FFT), and sliding DFT (SDFT) (also known as recursive DFT (RDFT)) are the most renowned approaches in the frequency-domain [8]-[10]. These approaches provide a good precision in ...
... classified into time-domain and frequency domain techniques. The digital Fourier transform (DFT), fast Fourier transform (FFT), and sliding DFT (SDFT) (also known as recursive DFT (RDFT)) are the most renowned approaches in the frequency-domain [8]-[10]. These approaches provide a good precision in ...
GEK-15021 Volts Per Hertz Regulator Panel
... generator speed (frequency). At this point, it would be helpful to describe how this average DC voltage across LlP is obtained. The saturable transformers used in this circuit are designed so that they will saturate in about 2/3 of each half-cycle during 60 Hz operation. The output from the saturabl ...
... generator speed (frequency). At this point, it would be helpful to describe how this average DC voltage across LlP is obtained. The saturable transformers used in this circuit are designed so that they will saturate in about 2/3 of each half-cycle during 60 Hz operation. The output from the saturabl ...
Current Probes Datasheet
... available in a variety of models for a range of Teledyne LeCroy current probes includes models with bandwidths up to 100 MHz, peak currents up to 700 A and sensitivities to 1 mA/div. Teledyne LeCroy current probes are often used in applications such as the design and test of switching power supplies ...
... available in a variety of models for a range of Teledyne LeCroy current probes includes models with bandwidths up to 100 MHz, peak currents up to 700 A and sensitivities to 1 mA/div. Teledyne LeCroy current probes are often used in applications such as the design and test of switching power supplies ...
frequency A - Department of Physics | Oregon State
... Y is determined by the circuit parameters L, R, C, and is also dependent on the frequency of the driving force. We have learned that Y can be written as a complex number whose amplitude tells how large the current is for a given V and whose phase tells how much I(t) is shifted wrt V(t). (see previou ...
... Y is determined by the circuit parameters L, R, C, and is also dependent on the frequency of the driving force. We have learned that Y can be written as a complex number whose amplitude tells how large the current is for a given V and whose phase tells how much I(t) is shifted wrt V(t). (see previou ...
Model: HPCW-640 D5-6
... Prime power is the maximum power available during a variable power sequence, which may be run for an unlimited number of hours per year, between stated maintenance intervals. The permissible average power output during a 24 hours period shall not exceed 80% of the prime power. 10% overload available ...
... Prime power is the maximum power available during a variable power sequence, which may be run for an unlimited number of hours per year, between stated maintenance intervals. The permissible average power output during a 24 hours period shall not exceed 80% of the prime power. 10% overload available ...
Utility frequency
The utility frequency, (power) line frequency (American English) or mains frequency (British English) is the frequency of the oscillations of alternating current (AC) in an electric power grid transmitted from a power plant to the end-user. In large parts of the world this is 50 Hz, although in the Americas and parts of Asia it is typically 60 Hz. Current usage by country or region is given in the list of mains power around the world.During the development of commercial electric power systems in the late 19th and early 20th centuries, many different frequencies (and voltages) had been used. Large investment in equipment at one frequency made standardization a slow process. However, as of the turn of the 21st century, places that now use the 50 Hz frequency tend to use 220–240 V, and those that now use 60 Hz tend to use 100–127 V. Both frequencies coexist today (Japan uses both) with no great technical reason to prefer one over the other and no apparent desire for complete worldwide standardization.Unless specified by the manufacturer to operate on both 50 and 60 Hz, appliances may not operate efficiently or even safely if used on anything other than the intended frequency.