• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
emergency power – storage batteries
emergency power – storage batteries

... pulsating loads well. DC Inverter – This type of generator supplies DC current that is then converted to 60 Hz 120 VAC power by an electronic inverter. The motor speed can vary with load and can respond more quickly to pulsating loads since a constant RPM is not necessary. The fuel economy of this c ...
- Emicro Technologies
- Emicro Technologies

electronic control of electrical machines
electronic control of electrical machines

as a PDF
as a PDF

... A high speed LM319 comparator is used. Extra circuitry was required to protect the comparator inputs, and meet its input common mode and differential mode requirements. The emitter of the comparator output transistor is wired to primary side gate drive. This ensures that the synchronous MOSFET will ...
(AFE) Drives - Mirus International
(AFE) Drives - Mirus International

... over standard 6-Pulse VFDs equipped with diode bridge rectifiers such as, reduced line current harmonics, improved power factor and inherent regenerative capabilities. But they will hide the fact that current harmonics are much higher when measured above the 50th and that very serious problems can r ...
AC motors
AC motors

... • Single-phase induction motor: It has one stator winding and a squirrel cage rotor. It operates with a single-phase power supply and requires a device to start the motor. • Three-phase induction motor: The rotating magnetic field is produced by the balanced three-phase power supply. These motors ca ...
Evaluation of Magnetic Materials for Very High Frequency Power
Evaluation of Magnetic Materials for Very High Frequency Power

RFVC1843 数据资料DataSheet下载
RFVC1843 数据资料DataSheet下载

A New Pulse Duty Cycle Control Method with Pulse Frequency
A New Pulse Duty Cycle Control Method with Pulse Frequency

... factor correction function.[1]The energy storage capacitor is necessary in the Single-Stage PFC, which is used to buffer the variation between the instantaneous input power and the output power. Conventionally, a bulk electrolytic capacitor is used to build the single-stage PFC achieves good power f ...
DC Motors
DC Motors

... Large AC generator •Unlike our generator model with a fixed magnetic field and rotating armature, it is more practical to fix the armature windings and rotate the magnetic field on large generators. •Brushes and slip rings pass EXCITATION voltage to the field windings on the rotor to create the mag ...
electronic instrumentation & plc dkt314
electronic instrumentation & plc dkt314

... AC Signal Conditioning System… continued • AC system is to overcome the problem of DC system. • Transducer can be variable resistance or variable inductance types. • Bridge circuit for modulating the amplitude of the output from the transducer stage. • The signal is then amplified and demodulated b ...
Microwave Devices Faculty of Engineering EMF2026 MULTIMEDIA
Microwave Devices Faculty of Engineering EMF2026 MULTIMEDIA

Understanding the Physics of Electrodynamic Shaker Performance
Understanding the Physics of Electrodynamic Shaker Performance

... damping is not evidenced. These plots reflect only the structural damping terms, those that could be measured with external excitation applied to the shaker with its drive coil unterminated. These same low damping factors are at play when the shaker is driven by a transconductance or ‘current’ ampli ...
Power Quality Problems and New Solutions
Power Quality Problems and New Solutions

... rotating electric machine (motor/generator) with a rotating mass to store energy for short durations. The motor/generator draws power provided by the grid to keep the rotor of the flywheel spinning. During a power disturbance, the kinetic energy stored in the rotor is transformed to DC electric ener ...
Induced Polarization
Induced Polarization

MF4 4th Order Switched Capacitor Butterworth Lowpass Filter
MF4 4th Order Switched Capacitor Butterworth Lowpass Filter

variable frequency 101
variable frequency 101

... separated by 180 degrees. As the AC wave form rises from zero to its maximum positive voltage, the upper pole has a north (N) polarity while the lower pole has a south (S) polarity. When the wave form changes direction and begins to fall, the poles change polarity and then change yet again when the ...
AVERAGE CURRENT MODE CONTROL OF A VOLTAGE SOURCE
AVERAGE CURRENT MODE CONTROL OF A VOLTAGE SOURCE

MAX7375 3-Pin Silicon Oscillator General Description Features
MAX7375 3-Pin Silicon Oscillator General Description Features

... positive supply connected 500Ω load to within 300mV of either supply rail. The clock output remains stable over the full operating voltage range and does not generate short output cycles during either power on or power off. A typical startup characteristic is shown in the Typical Operating Character ...
NCP2890, NCV2890 1.0 Watt Audio Power
NCP2890, NCV2890 1.0 Watt Audio Power

... shutdown pin, the bypass voltage begins to rise exponentially and once the output DC level is around the common mode voltage, the gain is established slowly (50 ms). This way to turn−on the device is optimized in terms of rejection of “pop and click” noises. The device has the same behavior when it ...
Slide
Slide

... • Memik et al. modeled errors in SRAM memory due to cross-talk noise as they overclock circuits. They use high degrees of overclocking — twice the nominal frequency and more. In the less than 25% overclocking regime that we consider, such cross-talk errors are negligible. For very small feature-size ...
Load_Benchmarking_update_EPRI
Load_Benchmarking_update_EPRI

Keysight Technologies Calibration of Time Base Oscillators
Keysight Technologies Calibration of Time Base Oscillators

AD8074
AD8074

... VOE < VDGND + 0.8 V. TTL logic levels are expected. The following restrictions are placed upon the digital ground potential: 3.5 V ≤ VAVCC – VDGND ≤ 12 V VDGND ≥ VAVEE ...
Aalborg Universitet Hierarchical Controlled Grid-Connected Microgrid based on a Novel Autonomous
Aalborg Universitet Hierarchical Controlled Grid-Connected Microgrid based on a Novel Autonomous

< 1 ... 140 141 142 143 144 145 146 147 148 ... 238 >

Utility frequency



The utility frequency, (power) line frequency (American English) or mains frequency (British English) is the frequency of the oscillations of alternating current (AC) in an electric power grid transmitted from a power plant to the end-user. In large parts of the world this is 50 Hz, although in the Americas and parts of Asia it is typically 60 Hz. Current usage by country or region is given in the list of mains power around the world.During the development of commercial electric power systems in the late 19th and early 20th centuries, many different frequencies (and voltages) had been used. Large investment in equipment at one frequency made standardization a slow process. However, as of the turn of the 21st century, places that now use the 50 Hz frequency tend to use 220–240 V, and those that now use 60 Hz tend to use 100–127 V. Both frequencies coexist today (Japan uses both) with no great technical reason to prefer one over the other and no apparent desire for complete worldwide standardization.Unless specified by the manufacturer to operate on both 50 and 60 Hz, appliances may not operate efficiently or even safely if used on anything other than the intended frequency.