
XR Series IV User Manual Programmable DC Power Supply
... aware of dealing with electrical hazards. Ensure that the AC power line ground is properly connected to the power supply chassis. Furthermore, other power grounds, including those connected to application maintenance equipment, must be grounded for both personnel and equipment safety. Always ensure ...
... aware of dealing with electrical hazards. Ensure that the AC power line ground is properly connected to the power supply chassis. Furthermore, other power grounds, including those connected to application maintenance equipment, must be grounded for both personnel and equipment safety. Always ensure ...
IF 1549 Revision 2
... accurate and up-to-date, Cooper Crouse-Hinds assumes no liability for damages resulting from any errors or omissions in this manual, or from the use of the information contained herein. Cooper Crouse-Hinds reserves the right to revise this manual without obligation to notify any person or organizati ...
... accurate and up-to-date, Cooper Crouse-Hinds assumes no liability for damages resulting from any errors or omissions in this manual, or from the use of the information contained herein. Cooper Crouse-Hinds reserves the right to revise this manual without obligation to notify any person or organizati ...
WT300 Series THE 5TH GENERATION OF THE WORLD'S BEST SELLING POWER METER
... trustworthy power measurement solutions for testing the standby and off mode power of household products and office equipment. The solution enables testing to be performed according to the IEC62301 Ed1.0 and Ed2.0 standards which specify the use of special algorithms for determining the power stabil ...
... trustworthy power measurement solutions for testing the standby and off mode power of household products and office equipment. The solution enables testing to be performed according to the IEC62301 Ed1.0 and Ed2.0 standards which specify the use of special algorithms for determining the power stabil ...
SKY77435 数据资料DataSheet下载
... © 2008, Skyworks Solutions, Inc. All Rights Reserved. Information in this document is provided in connection with Skyworks Solutions, Inc. (“Skyworks”) products or services. These materials, including the information contained herein, are provided by Skyworks as a service to its customers and may be ...
... © 2008, Skyworks Solutions, Inc. All Rights Reserved. Information in this document is provided in connection with Skyworks Solutions, Inc. (“Skyworks”) products or services. These materials, including the information contained herein, are provided by Skyworks as a service to its customers and may be ...
MAX13410E–MAX13415E RS-485 Transceiver with Integrated Low-Dropout Regulator and AutoDirection Control General Description
... θJA (Note 1)...................................................................52.0°C/W θJC (Note 1).....................................................................6.0°C/W Lead Temperature (soldering, 10s) ................................+300°C ...
... θJA (Note 1)...................................................................52.0°C/W θJC (Note 1).....................................................................6.0°C/W Lead Temperature (soldering, 10s) ................................+300°C ...
AR044280284
... should be larger to reach the input matching. However, an increasing R1 brings about the negative results as stated above. Seen from formulae (7) and (8), the input and output impedances are independent each other, as a result of which, better VSWRs representing impedance matchings can be obtained i ...
... should be larger to reach the input matching. However, an increasing R1 brings about the negative results as stated above. Seen from formulae (7) and (8), the input and output impedances are independent each other, as a result of which, better VSWRs representing impedance matchings can be obtained i ...
to this file: /ucq_series
... noted. General conditions for Specifications are +25 deg.C, Vin and Vout = nominal, full load. Adequate airflow must be supplied for extended testing under power. (2) Input Ripple Current is tested and specified over a 5 Hz to 20 MHz bandwidth. Input filtering is Cin = 33 µF, 100V tantalum, Cbus = ...
... noted. General conditions for Specifications are +25 deg.C, Vin and Vout = nominal, full load. Adequate airflow must be supplied for extended testing under power. (2) Input Ripple Current is tested and specified over a 5 Hz to 20 MHz bandwidth. Input filtering is Cin = 33 µF, 100V tantalum, Cbus = ...
Performance Verification of Low Noise, Low Dropout Regulators
... regulator noise vs various values of CBYP. 10a shows substantial noise for CBYP = 0µF, while 10d displays nearly 9× improvement with CBYP = 0.01µF; intermediate values of C BYP (10b and 10c) produce commensurate results. Interpreting Comparative Results Figure 11’s photos compare an LT1761-5’s outpu ...
... regulator noise vs various values of CBYP. 10a shows substantial noise for CBYP = 0µF, while 10d displays nearly 9× improvement with CBYP = 0.01µF; intermediate values of C BYP (10b and 10c) produce commensurate results. Interpreting Comparative Results Figure 11’s photos compare an LT1761-5’s outpu ...
UFC 3-540-01 Engine-Driven Generator Systems for
... to the Military Departments, the Defense Agencies, and the DoD Field Activities in accordance with USD (AT&L) Memorandum dated 29 May 2002. UFC will be used for all DoD projects and work for other customers where appropriate. All construction outside of the United States is also governed by Status o ...
... to the Military Departments, the Defense Agencies, and the DoD Field Activities in accordance with USD (AT&L) Memorandum dated 29 May 2002. UFC will be used for all DoD projects and work for other customers where appropriate. All construction outside of the United States is also governed by Status o ...
Crate PSU Stress Analysis
... Junction temperature = Tcase + jc * Pd Where: Tcase = 70°C jc = Thermal resistance junction-to-case Pd = Power being dissipated by the device ...
... Junction temperature = Tcase + jc * Pd Where: Tcase = 70°C jc = Thermal resistance junction-to-case Pd = Power being dissipated by the device ...
GENESYS - TDK
... These products are high-power equipment with input power > 1kW for professional use and installation, Class A as defined by EN 55022: 1998+A1:2000+A2:2003 and EN 61000-3.3:1995+A2:2005. Futther, all products covered by this declaration are manufactured in accordance with ISO9001:2001 which ensure co ...
... These products are high-power equipment with input power > 1kW for professional use and installation, Class A as defined by EN 55022: 1998+A1:2000+A2:2003 and EN 61000-3.3:1995+A2:2005. Futther, all products covered by this declaration are manufactured in accordance with ISO9001:2001 which ensure co ...
A Portable 2-Transistor Picowatt Temperature
... very little power. One example is the use of such references in voltage regulators that operate during nW or pW-level sleep modes. The area should be minimized as well, particularly for implantable biomedical applications where smaller device size translates to less invasive surgeries. These restric ...
... very little power. One example is the use of such references in voltage regulators that operate during nW or pW-level sleep modes. The area should be minimized as well, particularly for implantable biomedical applications where smaller device size translates to less invasive surgeries. These restric ...
HP ProLiant BL p-Class System Setup and Installation Guide
... This symbol indicates the presence of a hot surface or hot component. If this surface is contacted, the potential for injury exists. WARNING: To reduce the risk of injury from a hot component, allow the surface to cool before touching. These symbols, on power supplies or systems, indicate that the e ...
... This symbol indicates the presence of a hot surface or hot component. If this surface is contacted, the potential for injury exists. WARNING: To reduce the risk of injury from a hot component, allow the surface to cool before touching. These symbols, on power supplies or systems, indicate that the e ...
Features
... (drawn) channel lengths, and are capable of supporting flip–flop toggle rates of 200 MHz at 3.3V and 180 MHz at 2.5V, and input to output delays as fast as 150ps at 3.3V. The architecture of the UA1E series allows for efficient conversion of many PLD architecture and FPGA device types with higher IO ...
... (drawn) channel lengths, and are capable of supporting flip–flop toggle rates of 200 MHz at 3.3V and 180 MHz at 2.5V, and input to output delays as fast as 150ps at 3.3V. The architecture of the UA1E series allows for efficient conversion of many PLD architecture and FPGA device types with higher IO ...
product catalogue - amelec Electronic GmbH
... Another great advantage of this type of power factor correction is the simple installation with low costs. The daily trend of the loads has a fundamental importance for the choice of most suitable power factor correction. In many systems, not all the loads work in the same time and some of them work ...
... Another great advantage of this type of power factor correction is the simple installation with low costs. The daily trend of the loads has a fundamental importance for the choice of most suitable power factor correction. In many systems, not all the loads work in the same time and some of them work ...
DESIGN AND EVALUATION OF A TRANSCUTANEOUS ENERGY
... and reasonable efficiency. The design of the primary circuit consists of an H-bridge switching network driving a planar spiral Litz wire primary coil. The primary also incoporates a novel circuit for detecting the presence of the secondary. The implanted secondary components include a complimentary ...
... and reasonable efficiency. The design of the primary circuit consists of an H-bridge switching network driving a planar spiral Litz wire primary coil. The primary also incoporates a novel circuit for detecting the presence of the secondary. The implanted secondary components include a complimentary ...
Manual - Geist
... For Global units use a minimum 1.5 mm2 nominal conductor cross-sectional area detachable power supply cord with ratings of 300 V and 75 °C. The power supply cord cable designation should be H03VV-F, H03VVH2-F, or better. For North American units use a minimum 14 AWG power supply cord with ratings of ...
... For Global units use a minimum 1.5 mm2 nominal conductor cross-sectional area detachable power supply cord with ratings of 300 V and 75 °C. The power supply cord cable designation should be H03VV-F, H03VVH2-F, or better. For North American units use a minimum 14 AWG power supply cord with ratings of ...
Calculation Method of Losses and Efficiency of Wind
... generator output, and various losses in the system can be calculated. Next, a calculation method of the efficiency for variable speed WGs using permanent magnet synchronous generator (PMSG) is presented. PMSG has some advantages over constant speed IG; i.e., PMSG can operate at the speed correspondi ...
... generator output, and various losses in the system can be calculated. Next, a calculation method of the efficiency for variable speed WGs using permanent magnet synchronous generator (PMSG) is presented. PMSG has some advantages over constant speed IG; i.e., PMSG can operate at the speed correspondi ...
MAX15003 Triple-Output Buck Controller with Tracking/Sequencing General Description
... Operating Junction Temperature Range ...........-40°C to +125°C Junction Temperature ......................................................+150°C Storage Temperature Range .............................-60°C to +150°C Lead Temperature (soldering, 10s) .................................+300°C Soldering ...
... Operating Junction Temperature Range ...........-40°C to +125°C Junction Temperature ......................................................+150°C Storage Temperature Range .............................-60°C to +150°C Lead Temperature (soldering, 10s) .................................+300°C Soldering ...
PoE Powered Device for 24 VAC Building Power Applications
... Referring to Figure 1, the 24 VAC auxiliary input circuit is shown to include the following items: • Input fuse F1 for local current fault protection. • MOV VR1 and back-to-back transorbs D1/D3 for input transient protection. • Common-mode choke L1 and filter capacitor C1 for EMI filtering. • Bridge ...
... Referring to Figure 1, the 24 VAC auxiliary input circuit is shown to include the following items: • Input fuse F1 for local current fault protection. • MOV VR1 and back-to-back transorbs D1/D3 for input transient protection. • Common-mode choke L1 and filter capacitor C1 for EMI filtering. • Bridge ...
ADL5504 数据手册DataSheet 下载
... chains from 450 MHz to 6000 MHz. Requiring only a single supply between 2.5 V and 3.3 V, the detector draws less than 1.8 mA. The input is internally ac-coupled and has a nominal input impedance of 500 Ω. The rms output is a linear-responding dc voltage with a conversion gain of 1.87 V/V rms at 900 ...
... chains from 450 MHz to 6000 MHz. Requiring only a single supply between 2.5 V and 3.3 V, the detector draws less than 1.8 mA. The input is internally ac-coupled and has a nominal input impedance of 500 Ω. The rms output is a linear-responding dc voltage with a conversion gain of 1.87 V/V rms at 900 ...
Audio power

Audio power is the electrical power transferred from an audio amplifier to a loudspeaker, measured in watts. The electrical power delivered to the loudspeaker, together with its sensitivity, determines the sound power level generated (with the rest being converted to heat).Amplifiers are limited in the electrical energy they can amplify, while loudspeakers are limited in the electrical energy they can convert to sound energy without distorting the audio signal or being damaged. These power ratings are important to consumers finding compatible products and comparing competitors.