Mode-locking of a CW laser 1 Introduction
... It was stated above that the pulse width is proportional to the inverse of the gain bandwidth. In fact, the transform limit on the time-bandwidth product is ∆τ ∆νg = .44 for the case of Gaussian pulses/Gaussian gain profile.1 The quantities ∆τ and ∆νg are measured as the full width at half maximum. ...
... It was stated above that the pulse width is proportional to the inverse of the gain bandwidth. In fact, the transform limit on the time-bandwidth product is ∆τ ∆νg = .44 for the case of Gaussian pulses/Gaussian gain profile.1 The quantities ∆τ and ∆νg are measured as the full width at half maximum. ...
Experiment #68 — Phase Locked Loops, the Basics
... the cosine of the phase difference, it will be about 5 kΩ. Without connecting any input is a great time to find bargains on tackle zero when the phase difference is 90° (cos signal, apply power and use an oscilloscope boxes. They make terrific parts and tool 90° = 0). It will be a maximum when the o ...
... the cosine of the phase difference, it will be about 5 kΩ. Without connecting any input is a great time to find bargains on tackle zero when the phase difference is 90° (cos signal, apply power and use an oscilloscope boxes. They make terrific parts and tool 90° = 0). It will be a maximum when the o ...
B. Tech. - Government College of Engineering Amravati
... phase transmission lines, skin effect and proximity effect, transposition, G.M.D. & G.M.R. methods, double circuit lines, bundled conductors, effect of earth on inductance and capacitance, interference with communication lines. Electrical characteristics of transmission line : V-I characteristics of ...
... phase transmission lines, skin effect and proximity effect, transposition, G.M.D. & G.M.R. methods, double circuit lines, bundled conductors, effect of earth on inductance and capacitance, interference with communication lines. Electrical characteristics of transmission line : V-I characteristics of ...
Introduction to Basic Electronic Components. Test and Measurement
... whose band gap corresponds to a particular wavelength according to equation Eg = 1.24 / λ where Eg is the band gap in ev and λ is the wavelength in microns. (e.g. red ~ 0.7 μ hence corresponding E g = 1.24 / 0.7 = 1.77 ev). When the pn junction is forward biased, the electrons are excited to conduct ...
... whose band gap corresponds to a particular wavelength according to equation Eg = 1.24 / λ where Eg is the band gap in ev and λ is the wavelength in microns. (e.g. red ~ 0.7 μ hence corresponding E g = 1.24 / 0.7 = 1.77 ev). When the pn junction is forward biased, the electrons are excited to conduct ...
Some problems with connecting renewable energy sources to the grid
... In this section, the details of how to implement a synchronverter will be described. A simple DC/AC converter (inverter) used to convert DC power into three-phase AC (or the other way round) is shown in Figure 3. It includes three inverter legs operated using pulse width modulation (PWM) and LC filt ...
... In this section, the details of how to implement a synchronverter will be described. A simple DC/AC converter (inverter) used to convert DC power into three-phase AC (or the other way round) is shown in Figure 3. It includes three inverter legs operated using pulse width modulation (PWM) and LC filt ...
Waveguide-based single-shot temporal cross-correlator
... and the signal waves with amplitudes Ap and As, respectively. This interaction yields an idler wave with an amplitude Ai(t), ...
... and the signal waves with amplitudes Ap and As, respectively. This interaction yields an idler wave with an amplitude Ai(t), ...
Oscilloscopes
... Along with the multimeter the oscilloscope is the second most useful electrical measuring instrument found in all scientific laboratories. The use of this instrument is so ubiquitous that any one embarking on a scientific career of any discipline must master its operation. Oscilloscopes are used in ...
... Along with the multimeter the oscilloscope is the second most useful electrical measuring instrument found in all scientific laboratories. The use of this instrument is so ubiquitous that any one embarking on a scientific career of any discipline must master its operation. Oscilloscopes are used in ...
a possible water depth measuring system using ultrasonic wave
... strength is very poor i.e. amplitude of the signal generated by the piezo electrical crystal is at microvolt level. The weak from the crystal is given to the high gain amplifier 1. This amplifier is nothing but the operational amplifier which is in inverting mode. The inverting op amp is designed fo ...
... strength is very poor i.e. amplitude of the signal generated by the piezo electrical crystal is at microvolt level. The weak from the crystal is given to the high gain amplifier 1. This amplifier is nothing but the operational amplifier which is in inverting mode. The inverting op amp is designed fo ...