Download Koostada juurdepääsuvõrk, tagamaks kuni 30 terminaali

Survey
yes no Was this document useful for you?
   Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Document related concepts

Registered jack wikipedia , lookup

Network tap wikipedia , lookup

Parallel port wikipedia , lookup

IEEE 1355 wikipedia , lookup

Nonblocking minimal spanning switch wikipedia , lookup

IEEE 1394 wikipedia , lookup

IEEE 802.11 wikipedia , lookup

Extensible Authentication Protocol wikipedia , lookup

IEEE 802.1aq wikipedia , lookup

Spanning Tree Protocol wikipedia , lookup

Zero-configuration networking wikipedia , lookup

Point-to-Point Protocol over Ethernet wikipedia , lookup

Power over Ethernet wikipedia , lookup

Virtual LAN wikipedia , lookup

Transcript
Eesti Infotehnoloogia Kolledž
Grupitöö aines
“Sidevõrgud”
Koostajad:
Rainer Margus
ID 11024678
Andres Vares
ID 11012870
Kaspar Väärtnõu
ID 10013113
Juhendaja:
Avo Ots
Tallinn
2004
Eesti Infotehnoloogia Kolledž
Sisukord
1.
2.
3.
4.
5.
6.
7.
Ülesande püstitus ............................................................................................................. 3
Ülesande lahendus ........................................................................................................... 3
2.1
Piirangud .................................................................................................................. 3
2.1.1
Seadmete paigutus ruumis: ............................................................................. 3
2.1.2
Andmevoog switchide ja andmeserveri vahel. ................................................ 4
Vajalikud seadmed ............................................................................................................ 4
Hinnaarvutus ..................................................................................................................... 4
Hallatavus ......................................................................................................................... 5
Realiseeritavus ja töökindlus ............................................................................................ 5
Lisa A: spetsifikatsioonid ................................................................................................... 6
7.1
Andmeserver ............................................................................................................ 6
7.2
AT-8012M, 12 port 10/100TX managed switch ....................................................... 6
7.3
AT-8024M, 24 port 10/100TX managed switch ....................................................... 7
7.4
AT-8350GB - 48 port 10/100TX managed stackable Fast Ethernet switch ............. 8
7.5
RAPIER G6 6 port 1000T managed Gigabit Ethernet Layer 3 switch ................... 10
lk 2/12
Eesti Infotehnoloogia Kolledž
1. Ülesande püstitus
Koostada juurdepääsuvõrk, tagamaks kuni 30 terminaali (infovoog
a’ 8 Mbit/s) ühendamine võrku kasutades keerdpaar võrguühendust ja valida
sobib ühendusviis andmeserveriga eeldades terminaalide üheaegset
infokasutust.
Terminaalid paiknevad ruudukujulises ruumis, mille külje pikkus on 200 m.
2. Ülesande lahendus
2.1 Piirangud
2.1.1 Seadmete paigutus ruumis:
Joonis 1: seadmete paigutus ruumis
- Switch
- Server
- Ühe switchi maksimaalne ühenduskaugus
- Ruumi seinad
- UTP - kaabel
lk 3/12
Eesti Infotehnoloogia Kolledž
Et katta kogu ruum võrguga, tuleb kasutada mitut võrguseadet. Meie
lahenduses asub üks switch ruumi keskel ning neli switchi on ruumis laiali
jaotatud. Need neli switchi on ühendatud ühe “peaswitchiga”, mis on
omakorda ühenduses serveriga. Meie lahenduses pakutud seadmetega on
võrguühendus garanteeritud terminalide igasuguse paigutuse puhul.
2.1.2 Andmevoog switchide ja andmeserveri vahel.
Lähteandmetes antud 30 terminali puhul on võrgu, millele peab olema
garanteeritud 8 Mbit/s ühendus, maksimaalkoormuseks 240 Mbit/s. Seetõttu
ei piisa peakanalitele Fast Ethernet (100 Mbit/s) ühendusest, vaid tuleb
kasutada Gigabit Ethernetti. Antud nõuete juures võimaldab see veel hiljem
võrku lisada kuni 45 terminali. Switchid ja terminalid on ühendatud tänapäeval
kõige levinuma Fast Ethernet ühendusega (100 Mbit/s).
3. Vajalikud seadmed
Seadmete valikul lähtusime seadmete tehnilistest omadustest ja kvaliteedist.
Switchid toetavad mõlemas suunas ühenduskiirusi 10/100 Mbps, lisamooduli
abil saab kiiruse tõsta 1000Mbps-ini. Valisime kaks 12 pordiga, ühe 24
pordiga ja ühe 50 pordiga switchi, kuna sellisel moel on võimalik tagada
ühendused kogu ruumis, sõltumata terminalide paiknemisest. Kõik switchid on
firma Allied Telesyn tooted, kuna nimetatud firma võrgutooted on ala
spetsialistide poolt soovitatud. 12 pordiga switchide mudeliks on AT-8012M,
24 pordiga switchi tähiseks on AT-8024M ja 50 pordiga switch on AT8350GB. Lisaks on olemas veel „peaswitch“, mis toob neli alamswitchi kokku
ning milleks on Allied Telesyni Rapier G6 kuue pordiga Gigabit Ethernetswitch.
Andmeserver sisaldab ühte võrgukaarti, mis on valmistatud firma Allied
Telesyn poolt, mudeliks on AT-2930T Gigabit Ethernet PCI Adapter. See on
ühenduses peaswitchiga.
4. Hinnaarvutus
Seadmete andmed pärinevad tootja kodulehelt (www.alliedtelesyn.com)
Seadme nimetus
AT-8012M, 12 port 10/100TX managed switch
AT-G8T Gigabit Expansion Module
AT-A47 Switch/Mod Open GBIC Slot
AT-8024M, 24 port 10/100TX managed switch
AT-8350GB - 48 port 10/100TX managed stackable Fast
Ethernet switch
Rapier G6 - 6 port 1000T managed Gigabit Ethernet Layer 3
switch
Cat5 kategooria UTP võrgukaabel (pikkus ligikaudne)
Võrgukaabli seinapesad (RJ-45)
Kokku:
Tüki
hind
EEK
4500.2500.1050.6500.15000.-
Kogus
Summa
tk
2
3
3
1
1
EEK
9000.7500.3150.6500.15000.-
30000.-
1
30000.-
15.-/m
70.-
350m
30
5250.2100.78500.-
lk 4/12
Eesti Infotehnoloogia Kolledž
5. Hallatavus
Haldamine on kulukas, seega oleks mõttekas kategoriseerida erinevad
tegevused, et kuluplaane paremini koostada. Samas tuleb märkida, et nii
kontroll, parandused ja muudatused on võrdväärselt olulised aspektid võrgu
haldamisel. Kui ühes neist komponentidest tekib tõrge ei ole hallatavus enam
korrektne ning tihtipeale isegi võimalik.
 Kontroll –meie süsteem võimaldab lisada RMON-seadmeid, mis
teostavad võrgu monitooringut ja teatavad koheselt võimalikest
vigadest. Ning loomulikult tuleb kogu süsteemi aeg-ajalt kontrollida, et
välja selgitada süsteemi hetkeolukord ja võimalikud vead. Eriti hoolikalt
tuleb kontrollida süsteemi nõrku kohti, ehk siis peaswitchi ja selle
ühendust andmeserveriga. Samuti tuleb teostada turvakontroll,
tagamaks turvalisust võimalike kahjulike programmide eest, näiteks
viiruste ja „usside“ eest.
 Parandused – juhul kui vaja midagi korrastada või välja vahetada peab
olema valmis igaks olukorraks, ka kõige hullemaks. Samas tuleb
ehitada kaitsemehhanismid, mis takistaksid loodusjõudude poolt
tulenevat võimalikku kahju.
 Muudatused – on kas tarkvarapõhised (patchid, uuemad Linuxi
distributsioonid jne) või riistvarapõhised (meie süsteemi on võimalik
vastavalt vajadusele ümber paigutada, samuti saab terminale lisada.
Kuni 38 terminali korral on paigutus täiesti vaba, sealt edasi tekivad
juba piirangud)
6. Realiseeritavus ja töökindlus
Töökindlus on hea, kuna näiteks ühe switchi äralangemine ei halva veel kogu
võrgu tegevust. Et veelgi töökindlust suurendada, on hangitud kvaliteetsed
tooted tuntud ja hea mainega firmalt. Projekt tuleb selle tõttu küll kallim, aga
pikemas perspektiivis tasub see kindlasti ära.
Ka on süsteemi hea realiseerida, kuna skeem ja ülesehitus on küllaltki lihtsad.
Probleeme võib tekkida seadmete paigaldamisega. Nimelt oleks switchid
soovitav paigaldada vahelae peale või siis lakke (vahelae puudumisel).
Andmeserver tuleb paigutada keset tuba asuvasse lukustatavasse racki.
Andmeserverist jooksevad UTP-kaablid mööda kaabliredelit üles lae kohale
ning sealt plasttorudesse või –karbikutesse paigutatuna laiali switchide juurde.
lk 5/12
Eesti Infotehnoloogia Kolledž
7. Lisa A: spetsifikatsioonid
7.1 Andmeserver
Protsessor
Mälu
Opsüsteem
Võrgukaart
Kõvakettad
AMD Athlon 2,0 GHz
1 GB PC-2700 DDR
Linux 2.6.4 (Debian GNU)
AT-2930T Gigabit Ethernet PCI Adapter
2 x Seagate 120 Gbyte Serial ATA primaarseks andmesalvestuseks
1 x Seagate 120 Gbyte ATA disk backupiks
7.2 AT-8012M, 12 port 10/100TX managed switch plus 1 expansion bay
PERFORMANCE
Wirespeed switching on all Ethernet ports
Up to 6.5Mpps throughput
14,880pps for 10Mbps Ethernet
148,800pps for 100Mbps Fast Ethernet
1,488,000pps for 1000Mbps Gigabit Ethernet
Store and forward mode
9.6Gbps switch fabric
Head of Line blocking prevention
Broadcast Storm control
RAM
MAC Addresses
VLANs
Half/Full Duplex
Auto Negotiation
Auto MDI/MDI-X on all ports
24MB divided into
6MB Buffer Memory
18MB System Memory
Up to 4K
32
RELIABILITY
MTBF 200,000+ hrs
MTTR <1/2 hr DoA <1%
INTERFACE CONNECTIONS
10/100TX
100FX
RS232
Power supply
Internal power supply
RJ-45
SC or MT
DB9 pin, female port
5-15 NEMA plug
POWER CHARACTERISTICS
Voltage
Current
Power Consumption
Frequency
100-240vAC
4.0/2.0A
63W Maximum
50-60Hz
ENVIRONMENTAL SPECIFICATIONS
Operating Temp.
Storage Temp.
Relative Humidity
Storage Humidity
Operating Altitude
0°C to 40°C (32°F to 104°F)
-25°C to 70°C (-13°F to 158°F)
5% to 95% non-condensing
5% to 95% non-condensing
maximum 3,000m (9,843ft)
PHYSICAL CHARACTERISTICS
4.4cm (1.8") x 29.2cm (11.5") x 21.0cm (8.3"), 2.2kgs (4.9lbs)
Mounting
19" rack mountable hardware included
STANDARDS & COMPLIANCE
802.1d
Bridging
lk 6/12
Eesti Infotehnoloogia Kolledž
802.1D
802.1p
802.1P
802.1Q
802.1w
802.1x
802.3
802.3ab
802.3ac
802.3ad
802.3u
802.3x
802.3z
RFC 1112
RFC 2236
RFC 2865
RFC 783
RFC 951
TACACS+
SNMP STANDARDS
RFC 1157
RFC 1213
RFC 1215
RFC 1493
RFC 1643
RFC 1757
RFC 2674
RFC 2863
Allied Telesyn Private MIB
ELECTRICAL/MECHANICAL APPROVALS
Safety
EMI
Immunity
COUNTRY OF ORIGIN
China
Spanning Tree Protocol
Class of service
Traffic filtering, dynamic multicast filtering
VLAN bridge
Rapid Spanning Tree
Port-based network access control
10T Ethernet
1000T
VLAN tag frame extension
Link aggregation (static)
100TX Ethernet
Back pressure/flow control
1000SX
IGMP Snooping v1.0
IGMP Snooping v2.0
RADIUS
TFTP
BOOTP
SNMPv1/v2
MIB-II
TRAP MIB
Bridge MIB
Ethernet-like MIB
RMON 4 Groups: stats, history, alarms & events
802.1Q MIB
Interfaces Group MIB
UL 1950 (UL/cUL), EN60950 (TUV)
FCC Class A, EN55022 Class A, VCCI Class A,
C-TICK, EN61000-3-2, EN61000-3-3
EN55024
7.3 AT-8024M, 24 port 10/100TX managed switch plus 2 expansion bays
PERFORMANCE
Wirespeed switching on all Ethernet ports
Up to 6.5Mpps throughput
14,880pps for 10Mbps Ethernet
148,800pps for 100Mbps Fast Ethernet
1,488,000pps for 1000Mbps Gigabit Ethernet
Store and forward mode
9.6Gbps switch fabric
Head of Line blocking prevention
Broadcast Storm control
RAM
MAC Addresses
VLANs
Half/Full Duplex
Auto Negotiation
Auto MDI/MDI-X on all ports
RELIABILITY
MTBF
MTTR
INTERFACE CONNECTIONS
10/100TX
100FX
RS232
Power supply
Internal power supply
24MB divided into
6MB Buffer Memory
18MB System Memory
Up to 4K
32
200,000+ hrs
<1/2 hr DoA <1%
RJ-45
SC or MT
DB9 pin, female port
5-15 NEMA plug
lk 7/12
Eesti Infotehnoloogia Kolledž
POWER CHARACTERISTICS
Voltage
Current
Power Consumption
Frequency
100-240vAC
4.0/2.0A
63W Maximum
50-60Hz
ENVIRONMENTAL SPECIFICATIONS
Operating Temp.
Storage Temp.
Relative Humidity
Storage Humidity
Operating Altitude
0°C to 40°C (32°F to 104°F)
-25°C to 70°C (-13°F to 158°
5% to 95% non-condensing
5% to 95% non-condensing
maximum 3,000m (9,843ft)
PHYSICAL CHARACTERISTICS
4.4cm (1.8") x 29.2cm (11.5") x 21.0cm (8.3"), 2.2kgs (4.9lbs)
Mounting
19" rack mountable hardware included
STANDARDS & COMPLIANCE
802.1d
Bridging
802.1D
Spanning Tree Protocol
802.1p
Class of service
802.1P
Traffic filtering, dynamic multicast filtering
802.1Q
VLAN bridge
802.1w
Rapid Spanning Tree
802.1x
Port-based network access control
802.3
10T Ethernet
802.3ab
1000T
802.3ac
VLAN tag frame extension
802.3ad
Link aggregation (static)
802.3u
100TX Ethernet
802.3x
Back pressure/flow control
802.3z
1000SX
RFC 1112
IGMP Snooping v1.0
RFC 2236
IGMP Snooping v2.0
RFC 2865
RADIUS
RFC 783
TFTP
RFC 951
BOOTP
TACACS+
SNMP STANDARDS
RFC 1157
RFC 1213
RFC 1215
RFC 1493
RFC 1643
RFC 1757
RFC 2674
RFC 2863
Allied Telesyn Private MIB
SNMPv1/v2
MIB-II
TRAP MIB
Bridge MIB
Ethernet-like MIB
RMON 4 Groups: stats, history, alarms & events
802.1Q MIB
Interfaces Group MIB
ELECTRICAL/MECHANICAL APPROVALS
Safety
UL 1950 (UL/cUL), EN60950 (TUV)
EMI
FCC Class A, EN55022 Class A, VCCI Class A,
C-TICK, EN61000-3-2, EN61000-3-3
Immunity
EN55024
COUNTRY OF ORIGIN
China
7.4 AT-8350GB - 48 port 10/100TX managed stackable Fast Ethernet
switch plus 2 copper Gigabit ports, 2 GBIC bays, and 1 expansion
bay
PERFORMANCE
17.2Gbps switch fabric
13.0Mpps forwarding rate
14,880pps for 10Mbps Ethernet
148,800pps for 100Mbps Ethernet
1,488,000pps for 1000Mbps Ethernet
lk 8/12
Eesti Infotehnoloogia Kolledž
MAC addresses
Buffer Memory
VLANs
Broadcast Storm Control
Head of Line Blocking Prevention
Half/Full Duplex
Auto-negotiation
Auto MDI/MDIX
8K
16MB
256
RELIABILITY
MTBF
120,000 hours
INTERFACE CONNECTIONS
100FX
10/100
RS232
SC or MT connectors
TX/1000T Shielded RJ-45
9 pin female
NETWORK MANAGEMENT
SNMP
Web Based Management
RS232 Console Access
Command Menu Interface (ATI Omega)
Telnet
POWER CHARACTERISTICS
Voltage
Current
Frequency
100-240vAC
4.0/2.0A
50-60Hz
ENVIRONMENTAL SPECIFICATIONS
Operating Temp.
0°C to 40°C (32°F to 104°F)
Non-Operating Temp.
-20°C to 70°C (-4F to 158°F)
Relative Humidity
95% noncondensing
PHYSICAL CHARACTERISTICS
Height
Width
Depth
Weight
Mounting
4.4cm (1.7”)
44cm (17.3”)
18.5cm (7.3”)
3.7kg (10lbs)
19" rackmountable, hardware included
STANDARDS AND COMPLIANCE
IEEE 802.3
IEEE 802.3u
IEEE 802.3ab
IEEE 802.3z
IEEE 802.3ad
IEEE 802.1d
IEEE 802.1p
IEEE 802.1Q
IEEE 802.3x
RFC 1112
RFC 2236
RFC 951
RFC 2131
RFC 1350
RFC 1757
10T Ethernet
100TX Ethernet
1000T Ethernet
1000X Ethernet
Link Aggregation
Spanning Tree
Class of Service, priority protocols
VLAN Tagging
Flow Control
IGMP Snooping v1
IGMP Snooping v2
BootP
DHCP
TFTP
RMON Groups 1,2,3 and 9
SNMP STANDARDS
RFC 1213
RFC 1493
RFC 1757
Private MIB
MIB II
Bridge MIB
Remote Network MIB
ELECTRICAL/MECHANICAL APPROVALS
UL 1950
FCC Class A
CSA 22.2 No. 950
EN55022 Class A
EN 60950 (TUV)
EN50082-1
lk 9/12
Eesti Infotehnoloogia Kolledž
COUNTRY OF ORIGIN
China
7.5 RAPIER G6 6 port 1000T managed Gigabit Ethernet Layer 3 switch
Hardware (Standard)
100/1000T (RJ-45)
1000BaseSX or LX (SC)
Gigabit uplink slots
6
–
2
Hardware (Options)
1000BaseSX (SC) uplink module
1000BaseLX (SC) uplink module
100/1000BaseT (RJ-45) uplink module
-48VDC power supply (option)
External Redundant Power Supply (RPS)
Y
Y
Y
Y
Y
Layer 2 Switching
L2 Wire-speed switching
Switch fabric bandwidth
Forwarding/filtering/route rate
IEEE 802.1D Spanning Tree
IEEE 802.1Q VLAN Tagging
IEEE 802.1p
QoS Priority Queues (egress)
IGMP Snooping
Port Trunking
Y
35Gbps
11.9Mpps
Y
Y
Y
4
Y
Y
Management
Port mirroring
Port security
Telnet CLI
Web-browser
SNMP
RMON (1-3, 9)
Y
Y
Y
Y
Y
Y
Basic Layer 3
L3 IP Wire-speed routing
IP TOS QoS
IP Static Routes
IP RIP, RIPv2
OSPFv2, VRRP
Y
Y
Y
Y
Y
Full Layer
IPX RIP routing (software)
AppleTalk routing (software)
PIM-DM Multicast
PIM-SM Multicast
RSVP QoS
DVMRP Multicast
3
Y
Y
Y
Y
Y
Y
STATUS INDICATORS
System LEDs:
Power
Fault
RPS
Green On Power
Red On Fault
Green On RPS
Per Port LEDs:
Link/Activity
Green Flashing
Amber On
Amber Flashing
Duplex/Collision
Amber On
Amber Flashing
Green On 1000Mbps Link
1000Mbps Activity
100Mbps Link
100Mbps Activity
Green On Full-duplex
Half-duplex
Collision
NETWORK MANAGEMENT
RS232 Console CLI
Telnet CLI
Web-browser support (HTTP)
lk 10/12
Eesti Infotehnoloogia Kolledž
SNMP
RMON (1-3, 9 groups)
MIB II (RFC 1213)
802.3 MAU MIB (RFC 2239)
Ethernet MIB (RFC 1643)
Bridge MIB (RFC 1493)
Extended Interface MIB (RFC 1573)
RIP v2 MIB (RFC 1724)
Proprietary MIB Extensions
OPERATIONAL CHARACTERISTICS
Rapier G6
Layer 2 addresses (MAC)
VLANs (802.1Q)
Switching mode
Buffer memory
Layer 3 IP addresses
Next router hops
Priority Queues
35Gbps non-blocking bandwidth
11.9Mpps route/filter/forward
148,880pps for Fast Ethernet/port
1,488,000pps for Gigabit Ethernet/port
8k
63
Store-and-Forward
4MB global
2k
16
4
INTERFACE CONNECTIONS
1000SX
1000LX
100/1000T
Multi-mode fiber (SC or MT-RJ) connector
Single-mode fiber SC connector
Shielded RJ-45 connector
POWER CHARACTERISTICS
AC: (-10, -20, -30, -40, -50 models)
Voltage
Frequency
Power consumption
100-120/200-240vAC
50/60Hz
95W max.
Forwarding/filtering rates
DC: (-80 models)
Input voltage
Power consumption
Output voltage
5vDC, 8A
12vDC, 1A
ENVIRONMENTAL SPECIFICATIONS
Operating Temp.
Non-operating Temp.
Relative Humidity
PHYSICAL CHARACTERISTICS
Dimensions (W/D/H)
(17.3” x 14” x 2.6”), 1.5RU
Weight
Mounting
-48vDC
95W max.
3.3vDC, 13A
0°C to 40°C (32°F to 104°F)
-25°C to 70°C (-13°F to 158°F)
95% max. Noncondensing
440mm x 356mm x 66mm
5.5kg (12lbs)
19” rackmount, hardware included
STANDARDS & PROTOCOLS
IEEE 802.3u
100TX
IEEE 802.3z
1000X
IEEE 802.3ab
1000T
IEEE 802.1D-1998
Spanning Tree Protocol
IEEE 802.1p
Traffic Priority
IEEE 802.1Q
VLAN Tagging
IEEE 802.3x
Flow Control, Full-duplex
RFC 1757
RMON
RFC 1112
IGMP Snooping
RFC 951/1542
BootP
RFC 1350
TFTP
RFC 1058
RIP
RFC 1723
RIP v2
RFC 2236
RFC 2178
OSPF
RFC 1812
IP router requirement
RFC 783
TFTP
RFC 854
Telnet
RFC 768
UDP
RFC 791
IP
lk 11/12
Eesti Infotehnoloogia Kolledž
DVMRP v3
PIM-Dense Mode v2
PIM-Sparse Mode
RSVP
RFC 792
RFC 793
RFC 826
RFC 2068
RFC 2131
RFC 2138
ICMP
TCP
ARP
HTTP
BootP/DHCP relay
RADIUS
ELECTRICAL/MECHANICAL APPROVALS
UL 1950 3rd edition, CSA 22.2 No. 950, EN60950 (TUV), VCCI Class 1,FCC Part 15 Class A, EN55022 Class
A, EN50082-1
lk 12/12