BX-45
Lynx Panel Meter
4 1/2 DIGIT 0.56” LED
in a 1/16 DIN Case
LYNX FAMILY
A versatile panel meter that utilizes many different types of plug-in signal conditioners.
General Features
•
Input Module Compatibility
✔ LYNX FAMILY: More than 33 different Plug-in
External transmitters or signal conditioners can be eliminated
I-Series Input Signal Conditioners are approved for
Texmate’s Lynx Family of meters. As shown on
pages 3 to 5.
by directly connecting the sensor to more than 33 I-Series
Plug-in Input Signal Conditioners that include:
•
See www.texmate.com for an up to date listing.
– AC Current
– Process
– AC Voltage
– Prototype
– DC Current
– Resistance
– DC Voltage
– Strain-gage
– Load Cell
–Temperature
– Pressure
– 4 to 20 mA
Specifications
Precalibrated I-Series input modules, that have span or zero
potentiometers, can be interchanged between any I-Series
compatible meter, without recalibration, because all of the analog
scaling and reference circuitry is self-contained within the module.
•
24 V DC excitation is available to power external transmitters
and 5 or 10 V DC excitation is available for strain-gages, load
cells and resistance bridge type sensors.
•
Auto-sensing AC/DC power supply. For voltages between
85-265 V AC / 95-370 V DC (PS1) or 15-36 V AC / 10-72 V DC (PS2).
•
LYNX
Standard red or optional green or super bright red 4 1/2-digit
0.56” LED with display range -19999 to 19999 (40000 counts).
•
Display brightness may be externally controlled.
•
1/16 DIN (96 x 24mm ) case easily mounts in thin or thick
panels (up to 2”).
Input Specs: ..............Depends on input signal conditioner
A/D Converter: ..........16 bit dual slope
Accuracy: ..................±(0.05% of reading + 3 counts)
Temp. Coeff.: ............100 ppm/°C (Typical)
Warm up time: ..........2 minutes
Conversion Rate: ......3 conversions per second (Typical)
Display:......................4 1/2 digit 0.56" Red LED display (std),
0.56” Green or Super Bright Red (optn).
Range –19999 to 19999 counts.
Polarity: ....................Assumed positive. Displays – negative
Decimal Selection:....Header under face plate, X•X•X•X•X
Positive Overrange:..All digits flash.
Negative Overrange: – negative sign and all digits flash
Power Supply: ..........AC/DC Auto sensing wide range supply
PS1 (std) ................85-265 VAC / 95-370 VDC @ 2.5W
PS2 ........................15-48 VAC / 10-72 VDC @ 2.5W
Operating Temp.: ......0 to 60 °C
Storage Temp: ..........–20 °C to 70 °C.
Relative Humidity: ....95% (non condensing)
Case Dimensions: ....1/16 DIN, Bezel: 96x24mm(3.78”x0.95”)
Depth behind bezel 122.2 mm (4.83")
Plus 12.7mm (0.5”) for Right-angled
connector.
Weight: ......................7 oz., 9 oz when packed
Index
Case Dimensions . . . . . . . . . . . . . . . . . . . .
Component Layout . . . . . . . . . . . . . . . . . .
Connector Pinouts . . . . . . . . . . . . . . . . . . .
Connectors . . . . . . . . . . . . . . . . . . . . . . . .
Functional Diagram . . . . . . . . . . . . . . . . . .
General Features . . . . . . . . . . . . . . . . . . . .
I-Series Input Signal Conditioning Modules
7/15/03 BX-45 Data Sheet (BX2)
. . . . . . . . . . . .7
. . . . . . . . . . . .3
. . . . . . . . . . . .2
. . . . . . . . . . . .2
. . . . . . . . . . . .2
. . . . . . . . . . . .1
. . . . . . . . . .3-5
Input Module Calibration Procedures . . . . . . . . . . . . . . .6-7
Input Module Compatibility . . . . . . . . . . . . . . . . . . . . . . . .1
Input Module Component Glossary . . . . . . . . . . . . . . . . . .6
Ordering Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
Pin Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
Texmate, Inc. Tel. (760) 598-9899 • www.texmate.com
Page 1
Functional Diagram
1 3 5 7 9
I-Series Input Signal
Socket for Input Signal
Conditioning Module
Conditioning Module
1
2
3
4
1
Input and output
pins vary for
different modules.
Please see the
specific module
data sheet for
details.
5
2 4 6 8 10
Input Hi
Input Lo
2
1.25 V
Bandgap
Reference
3
+5VDC
4
-5VDC
5
+24VDC
6
Analog Common
7
8
9
10
Ref Hi
System Ground
MUXO
47K
1
2
3
4
5
6
47K
0.22
+5V
–5V
GND
16 bit
dual slope
A to D
converter
1V
24 V Return
Display
Driver
9
10
11
12
Hold
Test
Common
Dim/Blank
AC Neutral, – DC 14
AC Line, + DC 15
0.56" Display
1XXX.X
1XX.XX
1X.XXX
1.XXXX
GND
PTC
EMI Filter
AC/DC Power Input
+5 V DC
Optional
Isolated
External
Grounding Switching
Pin
Supply
MOV
-5 V DC
Decimal Select Header
GND
+24 V DC
ISO
GND
BX-45 Functional Diagram
Connectors
Connector Pinouts
This meter comes standard with screw terminal plug connections.
This meter uses plug-in type screw terminal connectors for all input
and output connections. The power supply connections (pins 14
and 15) have a unique plug and socket outline to prevent cross connection. The main board uses standard right-angled connectors.
See Lynx Family Input
Signal Conditioning Modules
5
6
8
Top Catches
9 10 11 12
DIM / BLANK
4
TEST
3
COMMON
2
HOLD
1
14 15
AC
Neutral
– DC
AC
Line
+ DC
PS1
85 to 265 VAC
95 to 370 VDC
PS2
15 to 48 VAC
10 to 72 VDC
Pin Socket
Pin Socket
Input Power
Screw Terminal Plug
Right-angled
Screw Terminal Plug
:
Release From Bottom
!
TO REMOVE REAR COVER
WARNING AC and DC input signals and power supply voltages can be hazardous. Do Not connect live wires
to screw terminal plugs, and do not insert, remove or handle screw terminal plugs with live wires connected.
Pin Descriptions
Pins 1 to 6 - Input Module: See the individual pin out of the input signal conditioning module selected. Usually Pin 1 is the Signal Input
High pin and Pin 3 is the Signal Input Low pin. All calibration and
scaling functions are performed on the individual input signal conditioner module. See pages 6 and 7.
Pin 9 - Hold: If this pin is left unconnected the meter will operate in a
free running mode. When this pin is connected to the Common Pin
11, the meter display will be latched. A/D conversions will continue,
but the display will not be updated until Pin 9 is disconnected from
Pin 11.
Pin 10 - Display Test: When this pin is connected to the Common Pin
11, all segments of the display light up and 1888 is displayed. This is
used to detect any missing segments in the display.
Page 2
Pin 11 - Common: To Hold, Test or Dim the display, the respective
pins have to be connected to this Common Pin.
Pin 12 - Dim/Blank: When this pin is connected to the Common Pin
11 the display is blanked out. If it is connected through an external
1KΩ pot, the display may be dimmed.
Pin 14 & 15 - AC/DC Power Input: These pins are the power pins
of the meter and they only accept a special polarized screw terminal plug that can not be inserted into any other input socket. The
standard meter has a auto sensing AC/DC power supply that operates from 85-265 VAC/95-370 VDC (PS1 Std). An optional isolated
low voltage power supply that operates from 15-48 VAC/10-72 VDC
(PS2) is also available.
Texmate, Inc. Tel. (760) 598-9899 • www.texmate.com
7/15/03 BX-45 Data Sheet (BX2)
Component Layout
BX-45-XX-PS1 (High Voltage)
BX-45-XX-PS2 (Low Voltage)
Typical input signal conditioner shown
Typical input signal conditioner shown
24V Exc
OFF
ON
OFF
ON
Custom
200V
20V
2V
Custom
200V
20V
2V
24V Exc
< Increase Span Decrease >
< Increase Span Decrease >
HV
LV
High Voltage
Transformer is
Colored Grey
Low Voltage
Transformer is
Colored Black
I-Series Input Signal Conditioning Modules
Many additional input modules are available and others are constantly being developed. Check with your local distributor or www.texmate.com
for updated information.
Precalibrated I-Series input modules, that have span or zero potentiometers, can be interchanged between any I-Series compatible meter,
without recalibration, because all of the analog scaling and reference circuitry is self-contained within the module. Where appropriate, all the
standard ranges shown are designed to be header selectable by the user, and Texmate's unique SPAN ADJUST Header facilitates scaling to
almost any required engineering unit. See Input Module Component Glossary and Calibration on pages 6 and 8.
Unless otherwise specified Texmate will ship all modules precalibrated with factory preselected ranges and/or scalings as shown in BOLD
type. Other precalibrated standard ranges or custom ranges may be ordered. Factory installed custom scaling and other custom options are
also available (see Ordering Information, Special Options on last page).
Symbols Indicate Module Compatibility Within Meter Families
IA03: AC Milliamps Scaled RMS, 2/20/200mA AC
280A
TIGER Family
TIGER Family
TIGER Family
LEOPARD Family
LEOPARD Family
LEOPARD Family
HI
AC mA
TIGER
AC mA
2mA
LO
20mA
LEOPARD
LYNX Family
LYNX Family
LYNX Family
MODEL SPECIFIC
SOME MODELS
ALL MODELS
200mA
LYNX
IA04: AC Amps Scaled RMS, 1 Amp AC
IA05: AC Amps Scaled RMS, 5 Amp AC
IA01: AC Volts Scaled RMS, 200/600V AC
123A
065D
N
AC AMPS
600V
200V
LEOPARD
1A
Secondary
CT
TIGER
LEOPARD
LYNX
LYNX
IA02: AC Volts Scaled RMS, 200mV/2V/20V AC
Primary
AC Current
TIGER
< Increase Span Decrease >
LO
HI
L
Fully User Scalable
LO RANGE HI
IA06: AC Volts True RMS, 300/600V AC
140A
300C
ACV-LO
AC V RMS HI
TIGER
TIGER
600 V
300 V
20V
LEOPARD
2V
LEOPARD
0.2V
SPAN
LYNX
7/15/03 BX-45 Data Sheet (BX2)
LYNX
Texmate, Inc. Tel. (760) 598-9899 • www.texmate.com
Page 3
I-Series Input Signal Conditioning Modules Continued
ID02: DC Millivolts, 20/50/100/200mV DC w/24V DC Exc
IA07: AC Volts True RMS, 200mV/2V/20V AC
142A
369B
24V EXC
24V
Exc
PIN 2
LEOPARD
LEOPARD
LYNX
LYNX
IA08: AC Milliamps True RMS, 2/20/200mA AC
ON
TIGER
OFF
PIN 1
TIGER
200
100
50
20
DCmV
2 V / 20 V RMS
< Increase Span Decrease >
ID03: DC Milliamps, 2/20/200mA DC w/24V DC Exc
370B
141E
DCmA
24V
Exc
PIN 2
LEOPARD
LEOPARD
IP07
LYNX
LYNX
24V Exc
ON
TIGER
IP07
OFF
2 / 20 / 200 mA
RMS
2mA
20mA
200mA
TIGER
PIN 1
< Increase Span Decrease >
IA09: AC Amps True RMS, 1 Amp AC
IA11: AC Amps True RMS, 5 Amp AC
ID04: DC Amps, 5A DC
ID09: DC Amps, 1A DC
301B
065D
1A/5A
Secondary
CT
TIGER
TIGER
+
1 A Shunt
Primary
AC Current
+
LEOPARD
+
LEOPARD
LYNX
< Increase Span Decrease >
DC AMPS
AC AMPS RMS
Fully User Scalable
LYNX
IA10 AC Millivolts, Scaled RMS, 100mV AC
285A
TIGER
IP07
24V
Exc
OFF
LO
LEOPARD
090D
24V Exc
ON
ACmV
ID05: DC Volts 2/20/200/Custom V DC with Offset
and 24V Exc.
Custom
200V
20V
2V
TIGER
LO RANGE HI
ACI
< Increase Span Decrease >
ACmV
HI
Fully User Scalable
LEOPARD
IP07
LO RANGE HI
LYNX
IA12: AC Millivolt RMS Sigma Delta
371A
< Increase Span Decrease >
LYNX
ID07: DC Milliamps, 2/20/200mA DC with Offset
and 24V Exc
141E
HI
ACmV RMS
24V
Exc
LEOPARD
OFF
TIGER
IP07
LO
24V Exc
ON
2mA
20mA
200mA
TIGER
DCmA
PIN 1
PIN 2
+
Offset
0
_
Fully User Scalable
LEOPARD
IP07
Offset
< Increase Span Decrease >
LYNX
ID01: DC Volts, 2/20/200V/Custom w/24V DC Exc
IF02: Line Frequency
090D
OFF
ON
Custom
200V
20V
2V
24V
Exc
LEOPARD
IP07
269D
TIGER
IF06
60 to 500V AC
LEOPARD
Frequency to Voltage Conversion
< Increase Span Decrease >
Page 4
+
24V Exc
TIGER
IP07
LYNX
0
_
LYNX
LYNX
Texmate, Inc. Tel. (760) 598-9899 • www.texmate.com
ZERO
SPAN
7/15/03 BX-45 Data Sheet (BX2)
I-Series Input Signal Conditioning Modules Continued
IGYZ: Universal Direct Pressure (Absolute or Differential/Gage)
See below for ordering code options
IR04: Resistance 2KΩ (Lynx only)
IR05: Resistance 2KΩ (Leopard only)
128A
332D
TIGER
ABSOLUTE / DIFFERENTIAL
PRESSURE
LEOPARD (IR05)
Pt-100Ω
RTD
LEOPARD
3 wire
4 wire
LYNX (IR04)
3 wire
4 wire
LYNX
Ordering Code Options for Direct Pressure (IGYX, IGYY & IGYZ)
I
G
Sensor Range
CH1
Order Code
CH2
Order Code
A
B
B
5 psi Absolute
C
C
5 psi Differential
D
D
15 psi Absolute
E
TIGER
IS02
For Universal Direct Pressure
IGYZ, the last digit of order
code is always Z.
F
G
G
LEOPARD
IS02
30 psi Differential
H
H
100 psi Absolute
J
J
100 psi Differential
K
K
RANGE
HI
LO
F
30 psi Absolute
LYNX
IP01: Process Loop, 4-20mA
IP02: Process Loop, 4-20mA with 24VDC EXC
Other devices can be
added to the loop.
091E
0
_
TIGER
IS04
EXC
ON
LEOPARD
IS04
OFF
Range
LO
< Decrease Span Increase >
LYNX
091E
Common
0
_
1 to 5V
Offset
PIN 2
< Decrease Zero Increase >
Excitation is 1mA
Up to 50Ω resistance in each
lead can be compensated
_
24V EXC
+24 V
LEOPARD
IPO7
+
5 V or 10 V External Power
Supply Drift is Ratiometrically
Compensated by Module
IT03: RTD, 100Ω Pt. 2/ 3/4-wire (-200 to 800°C)
IT04: RTD, 100Ω Pt. 2/ 3/4-wire (-200 to 1470°F)
IT05: RTD, 100Ω Pt. 2/3/4-wire (-199.9 to 199.9°F)
IT14: RTD, 100Ω Pt. 2/3/4-wire (-199.9 to 199.9°C)
+
250Ω
PROCESS 1 to 5V DC
–
OFF
LEOPARD
LIN
3 wire
4 wire
LINEARISATION IS ANALOG
Typical accuracy is
±(0.3% + 1 digit)
3 wire
LO
4 wire
< Decrease Span Increase >
LEAD
COMP
Pt-100Ω
RTD
Range
Fully User Scalable
187C
RTD
TIGER
IT02
ON
HI
LYNX
RANGE
HI
LO
HI
IP03: Process Input, 1-5V DC with Offset, 24V Exc
TIGER
IP07
2
10V
5V
EXT
24V EXC
_
24V
Common
External
Loop Supply
+ 1 to 5V Input
mV/V
PRESSURE
20
Fully User Scalable
4/20mA
244C
For multiple pressure transducers
+
< Decrease Zero Increase >
PIN 2
LYNX
IS06: Pressure/Load Cell Ext Exc., 20/2mV/V, 4-wire
Offset
TIGER
+
2
20
E
15 psi Differential
244C
mV/V
PRESSURE
EXC
A
Pressure Transducer
or Load Cell
10V
5V
EXT
1 psi Absolute
1 psi Differential
LEOPARD
IS05: Pressure/Load Cell 20/2mV/V, 5/10V Exc 4-wire
For Single Channel IGYX with
two digital inputs, the last digit
of order code is always X.
LYNX
IR02: 3 wire Potentiometer 1KΩ min (0-F.S.)
273A
POTENTIOMETER
IT06: Thermocouple, J Type (0-1400 ˚F)
IT08: Thermocouple, J Type (0-760 ˚C)
LINEARISATION IS ANALOG
TIGER
T/C +
T/C –
TIGER
IT01
LEOPARD
1KΩ Minimum
1MΩ Maximum
Conformity error to NIST tables (at 25°C)
LEOPARD
100% Signal Span 1 K = 2000
< Increase Span Decrease >
LYNX
271D
J/K THERMOCOUPLE
J
J
K
K
±(2 ˚C + 1 digit) typical
±(4 ˚F + 1 digit) maximum
±(3 ˚C + 1 digit) typical
±(5 ˚F + 1 digit) maximum
LINEARITY
ZERO
SPAN
LYNX
IR03: Linear Potentiometer 1KΩ min
273A
Digital Scaling
TIGER
Input
POTENTIOMETER
272D
LINEARISATION IS ANALOG
Exc
Gnd
LEOPARD
IT07: Thermocouple, K Type (0-1999 °F)
IT09: Thermocouple, K Type (0-1260 °C)
T/C +
T/C –
TIGER
IT01
1KΩ Minimum
1MΩ Maximum
J/K THERMOCOUPLE
Conformity error to NIST tables (at 25°C)
LEOPARD
LYNX
J
J
K
K
±(2 °C + 1 digit) typical
±(4 °F + 1 digit) maximum
±(3°C + 1 digit) typical
±(5 °F + 1 digit) maximum
LINEARITY
ZERO
SPAN
LYNX
7/15/03 BX-45 Data Sheet (BX2)
Texmate, Inc. Tel. (760) 598-9899 • www.texmate.com
Page 5
Input Module Component Glossary
ZERO OFFSET RANGE Header
Input and Output Pins
HI
On most modules Pin 1 is the Signal High input
and Pin 3 is the Signal Low input. Typically Pin 2 is
used for Excitation Voltage output.
24V
Exc
LO
When provided, this three position header increases the ZERO pot’s capability to offset the input signal, to ±25% of the digital display span. For example a Negative offset enables a 1 to 5V input to
display 0 to full scale.The user can select negative
offset, positive offset, or no offset (ZERO pot disabled for two step non-interactive span and offset
calibration).
Offset
—
+
0
—
+
0
24V EXC
24V DC Output Header
ON
OFF
N
O
On some modules this header enables a 24V DC
25mA (max) Excitation/Auxiliary output to be connected to Pin 2.
Zero Offset Range Header
FF
O
NEGATIVE OFFSET
Decreases Digital Reading
INPUT RANGE Header
Range values are marked on the PCB.Typically two
to four positions are provided, which are selected
with either a single or multiple jumper clip. When
provided, a custom range position is only functional
when the option has been factory installed.
Custom
200V
20V
2V
ZERO Pot%
– 100% of Offset
Offset Range
≈ – 5000 Counts
–
Equivalent
Circuit
POSITIVE OFFSET
Increases Digital Reading
– 0 +
No
Offset
Zero Pot
Disabled
0
+ 100% of Offset
≈ + 5000 Counts
0
15 Turn Potentiometer
+
15 Turn Potentiometer
ZERO ADJUST Header
2 1
< Increase Span Decrease >
12
3
as
2 1
54
ZERO Pot %
Equivalent
Circuit
1
2
3
4
5
SPAN Pot %
20%
20%
20%
20%
20%
Signal Span %
20%
40%
60%
80%
100%
HI
Acts like 75 Turn 1 Megaohm Potentiometer
Input
HI
When this header is provided it works in conjunction with the SPAN ADJUST Header by splitting its
adjustment range into a Hi and a Lo range. This
has the effect of dividing the adjustment range of
the SPAN pot into ten equal 10% steps across
100% of the input Signal Span.
HI
Range
LO
Span Adjust Header
12
3
LO
< Decrease Span Increase >
12
HI
3
4 5
Span Range Header
< Decrease Span Increase >
LO RANGE
HI RANGE
SPAN Adjust
Header position
1
2
3
5
1
SPAN Pot %
10%
10%
10%
10%
10%
10%
10%
10% 10%
10%
Signal Span %
10%
20%
30%
40%
50%
60%
70%
80% 90%
100%
4
2
3
4
5
Equivalent
Circuit
Acts like a
150 Turn
Potentiometer
5
ZERO
Turn Clockwise to
Increase Reading
Input LO
Low Range
High Range
3
2
1
–20% –20% –20% –20% –20%
< Decrease Zero Increase >
1
2
3
4
5
Zero Pot
Disabled +20% +20% +20% +20% +20%
≈ –75% of display span
–
4 5
≈ +50% of display span
0
0
+
75 Turn Potentiometer
!
WARNING:
AC and DC input signals and power supply
voltages can be hazardous. Do Not insert, remove or handle
modules with live wires connected to any terminal plugs.
Basic standard range calibration of direct reading
modules that utilize either Auto Zero or a ZERO
pot, an INPUT RANGE Header and or a SPAN pot.
1 If the module has an INPUT RANGE Header, reposition the
jumper clip to select the desired input signal range.
3 Apply a known input signal that is at least 20% of the full scale
input range and adjust the SPAN pot until the display reads the
exact input value.
Input HI
If provided, the ZERO pot is always to the left of
the SPAN pot (as viewed from the rear of the
meter). Typically it enables the input signal to be
offset ±5% of full scale (-1000 to +1000 counts).
≈ – 1000 Counts
–
0
+
15 Turn Potentiometer
Page 6
4
3
4 Decimal Points.The selection or positioning of decimal points has
no effect on the calibration of the modules
ZERO Potentiometer (Pot)
To the
Left Rear
12
– 0 +
No
Offset
2. Apply a zero input or short the input pins. The display will auto
zero, or if the module has a ZERO pot, it should be adjusted until
the display reads zero.
Span Adjust Header
4 5
2 1
Zero Adjust Header
POSITIVE OFFSET
Input Module Calibration
SPAN RANGE Header
LO
3
75 Turn Potentiometer
Equivalent
Circuit
Input LO
Zero Offset Range Header
< Increase Zero Decrease >
ZERO Adjust
Header position
4 5
< Decrease Span Increase >
When this header is provided, it works in conjunction with the ZERO OFFSET RANGE Header, and
expands the ZERO pot’s offset capability into five
equal negative steps or five equal positive steps.
This enables virtually any degree of input signal
offset required to display any desired engineering
unit of measure.
Zero Adjust Header
NEGATIVE OFFSET
Offset Range
SPAN Adjust
Header position
1
cre
2
De
ro
3
Ze
e
as
re
4
3
< Increase Zero Decrease >
This unique five-position header expands the
adjustment range of the SPAN pot into five equal
20% steps, across 100% of the input Signal Span.
Any input Signal Span can then be precisely scaled
down to provide any required Digital Display span
from 19999 counts to 0001 (one count).
>
ase
ecre 2 1
nD
Spa 3
e
s
crea
< In 5 4
3
nc
5 4
SPAN ADJUST Header
5 4
5
SPAN
Turn Clockwise to
Increase Reading
<I
If provided, the 15 turn SPAN pot is always on the
right side (as viewed from the rear of the meter).
Typical adjustment is 20% of the input signal range.
e>
SPAN Potentiometer (Pot)
To the
Right Rear
≈ + 1000 Counts
Wide range scaling, in engineering units not requiring offsets, with modules that utilize auto-zero or a
ZERO pot, a SPAN RANGE Header and or a SPAN
ADJUST Header.
Texmate’s unique SPAN ADJUST and SPAN RANGE Headers provide the circuit equivalent of an ultra-precision one megohm 75 or
150 turn potentiometer that can infinitely scale down any Input
Signal SPAN to provide any full scale Digital Display Span from
19999 (counts) to 0001 (one count).
Texmate, Inc. Tel. (760) 598-9899 • www.texmate.com
7/15/03 BX-45 Data Sheet (BX2)
Input Module Calibration Procedures Continued
Example B: 1 to 5 V to read –100.0 to 1500.0 °C.
Signal Span = 4V, Digital Display Span = 16000 counts
If the module has an INPUT RANGE Header, and the required full
scale Digital Display Span (counts) is to be larger than the directly
measured value of the input Signal Span, then the next lower range on
the INPUT RANGE Header should be selected. The resulting over
range Signal Span is then scaled down, by selecting the position of the
SPAN RANGE Header and or the SPAN ADJUST Header, which will
reduce the input Signal Span to a percentage, that the required Digital
Display Span can be reached by calibration with the SPAN pot.
1 If the module has an INPUT RANGE Header the 2 V position should
be selected. This will provide a digital display of 16000 counts for an
input of 1.6 V which is (1.6 ÷ 4) = 40% of the examples 4 V signal
span. To scale down the Signal Span to 40% select the 40% Signal
Span position on the SPAN ADJUST Header (position 2).
2 If the module is a Process Input 1-5 V DC type, select the (Hi Range)
position on the SPAN RANGE Header and the 100% Signal Span
position on the SPAN ADJUST Header (position 5, max increase).
This will provide a digital display of 16000 counts for an input of 4V
which is 100% of the examples 4V Signal Span.
Example A: 0 to 10 V to read 0 to 18000 gallons.
Signal Span = 10V, Digital Display Span = 18000 counts
1 Select the 2 V INPUT RANGE Header position. This will provide
a digital display of 18000 counts with an input of only 1.8 V which
is (1.8÷10)=18% of the examples 10 V Signal Span.
3 Set the ZERO OFFSET RANGE Header to the center position
(no offset). Apply 1 V and adjust the SPAN pot until the display
reads 400 . A 4V input would then read 16000 counts.
2 To scale down the Signal Span to 18% select the 20% Signal Span position on the SPAN ADJUST Header (position 1) or if the module
has a SPAN RANGE Header, select (LO Range) and 20%
Signal Span position on the SPAN ADJUST Header (position 2).
4 Set the ZERO OFFSET RANGE Header to the negative offset
position. If the module has a ZERO ADJUST Header select the
position that will provide a negative offset of ≈ –500 counts.
Apply 1 V and adjust the ZERO pot until the display reads
–100. Apply 5 V and check that the display reads 15000. Select
decimal point 1XXX•X to display -100.0 to 1500.0.
3 Apply a zero input or short the input pins. The display will auto
zero, or if the module has a ZERO pot, it should be adjusted until
the display reads zero.
4 Apply 10 V and adjust the SPAN pot until the display reads 18000.
Example C: 4 to 20 mA to read 00.00 to +100.00%
Signal Span = 16 mA, Digital Display Span = 10000 counts.
Large offset scaling and calibration of process signal inputs with modules that utilize ZERO ADJUST
Headers and or ZERO OFFSET RANGE Headers.
1 The full scale Signal Span of the Process Input 4-20 mA modules
is 0 to 20 mA for a full scale Digital Display Span of 0 to 20000
counts. This will provide a digital display of 10000 counts with an
input of only 10 mA which is (10÷16)=62.5% of the examples 16
mA signal span.
Texmate’s unique ZERO OFFSET RANGE Header enables the
use of a simple two step scaling and calibration procedure for those
process signals that require large offsets. This eliminates the back
and forth interaction, between zero and span settings, that is often
required to calibrate less finely engineered products.
2 To scale down the Signal Span to 62.5% select the (Hi Range)
Position on the Span Range Header and the 70% Signal Span
position on the SPAN ADJUST Header (position 2).
The first step is to set the ZERO OFFSET RANGE Header to the
center position (No Offset) and scale down the Input Signal Span to
a percentage that will enable calibration with the SPAN pot to reach
the required Digital Display Span.
3 Set the ZERO OFFSET RANGE Header to the center position
(no offset). Apply 4 mA and adjust the SPAN pot until the display
reads 2500 . A 16 mA input would then read 10000 counts.
4 Set the ZERO OFFSET RANGE Header to the positive offset
position. If the module has a ZERO ADJUST Header select the
position that will provide a negative offset of ≈ –2500 counts.
Apply 4 mA and adjust the ZERO pot until the display reads 0000.
Apply 20 mA and check that the display reads 10000. Select decimal point 1XX•XX to display 00.00 to 100.00
The second step is to set the ZERO ADJUST and or ZERO OFFSET
RANGE Header to provide a positive or negative offset of sufficient
counts that calibration with the ZERO pot will offset the Digital Display
Span to produce the required digital reading.
Case Dimensions
PANEL CUTOUT
FRONT VIEW
Case will mount in
standard 1/16 DIN cutouts
1/16 DIN (96x24mm)
Snug Fit 91 mm
(3.59")
Loose Fit
21.85 mm
(0.86")
22.2 mm
(0.88")
92 mm
(3.62")
Panel adaptor plates are available
to retrofit most existing panel cutouts.
24 mm
(0.95")
3 mm
(0.12")
typical
SIDE VIEW
Right-angled
Connector
SP3
SP2
SP1
21.85mm
(0.86")
P
96 mm
(3.78")
5mm
(0.20")
Top
Catches
Bottom Catch
122.2mm
(4.83")
12.7mm
(0.5")
TOP VIEW
74.5mm (2.94")
When extra panel
mounting tightness
is required, optional
Screw Mounting Clips
are included which fit on
the Mounting Slide Clips.
Release Bottom Catch with a
small flat blade, and lever outwards.
Max. panel thickness
97.8mm
(3.86")
92.8 mm (3.6") Widest
mountable panel cutout
without using adaptors.
Removable
Key-lock
Safety
Catch
TO REMOVE REAR COVER
Cam
Opening
7/15/03 BX-45 Data Sheet (BX2)
91mm
(3.59")
Various bezel
colors are available.
Black is standard.
Clear Lockable NEMA 4X
Splash Proof Cover
can accept two 1/16 DIN
cases P/N:(OP-N4/96x48)
For additional strength, extra Mounting
Slide Clips can be ordered and doubled up
one behind the other. P/N:(75-DMT96X24)
Texmate, Inc. Tel. (760) 598-9899 • www.texmate.com
3.5mm (0.14")
Connector
Sockets
The 96x24mm case is
particularly suitable for mounting
in mosaic panels or insulative
panels up to 2" thick. They can
also stack mount, 2 up in existing
cut-outs for 1/8 DIN (96x48mm)
or 4 up in 1/4 DIN (96x96mm).
Page 7
Ordering Information
BASIC MODEL #
DISPLAY
POWER SUPPLY
INPUT MODULES
ANALOG OUTPUT OPTIONS / ACCESSORIES
BX-45
OA____
Add to the basic model number the order code suffix for each standard option required. The last suffix is to
indicate how many different special options and or accessories that you may require to be included with this product.
Ordering Example: BX-45-DR-PS1-IA01-OA2, the 2 OA’s are, CR-CHANGE and a 75-DMT96X24, $110 + N/C + N/C + 35 + 5+ 2 = $152
BASIC MODEL NUMBER
BX-45 . . . . 96x24mm, Lynx, 4.5 Digit . . . . . . . . . . . . . . . .$110
Standard Options for this Model Number
Order Code Suffix
Description
List
DISPLAY
DR . .Red LED, 0.56 inch high . . . . . . . . . . . . . . . . . . . . .N/C
DB . . . .Super–bright Red LED, 0.56 inch high . . . . . . . . . . . . . . . . . . . .$25
DG . . .Green LED, 0.56 inch high . . . . . . . . . . . . . . . . . . . . . . . . . . . .$10
POWER SUPPLY
PS1 . .85-265VAC/95-370VDC . . . . . . . . . . . . . . . . . . . . . .N/C
PS2 . . .15-48VAC/10-72VDC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .$35
INPUT MODULES (Partial List. See www.texmate.com)
Unless otherwise specified Texmate will ship all modules pre calibrated with factory
preselected ranges and/or scalings as shown in BOLD type.
IP01
IP02
IP03
IPT1
IR02
IR03
IR04
IS04
IS05
IS06
IT03
IT04
IT05
IT06
IT07
IT08
IT09
IT14
.
.
.
.
..
..
.
.
..
..
.
.
.
.
.
.
.
.
.Process Loop, 4-20mA(0-100.00) . . . . . . . . . . . . . . . . . . . .
.Process Loop, 4-20mA(0-100.00) w/24VDC Exc . . . . . . . . . .
.Process Input, 1-5V DC(0-100.00) w/Offset, 24V Exc . . . . . .
.Prototype Board for Custom Design . . . . . . . . . . . . . . . . . . . .
.3-Wire Potentiometer 1KΩ min (0-F.S.) . . . . . . . . . . . . . . . . . . . .
.Linear Potentiometer, 3-wire, 1KΩ min . . . . . . . . . . . . . . . . . . . .
.Resistance 2KΩ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
.Pressure Ext Exc., 20/2mV/V, 4/6–wire . . . . . . . . . . . . . . . . . .
.Pressure/Load Cell 20/2mV/V, 5/10V Exc 4-wire . . . . . . . . . . . . . .
.Pressure/Load Cell Ext Exc., 20/2mV/V, 4-wire . . . . . . . . . . . . . . .
.RTD, 100Ω Pt. 2/3/4-wire (-200 to 800°C) . . . . . . . . . . . . .
.RTD, 100Ω Pt. 2/3/4-wire (-200 to 1470°F) . . . . . . . . . . . . .
.RTD, 100Ω Pt. 2/3/4-wire (-190.0 to 199.0°F) . . . . . . . . . .
.Thermocouple, J Type (0-1400 °F) . . . . . . . . . . . . . . . . . . . .
.Thermocouple, K Type (0-1999°F) . . . . . . . . . . . . . . . . . . . .
.Thermocouple, J Type (0-760 °C) . . . . . . . . . . . . . . . . . . . . .
.Thermocouple, K Type (0-1260°C) . . . . . . . . . . . . . . . . . . . .
.RTD, 100Ω Pt. 2/3/4-wire (-199.0 to 199.0°C) . . . . . . . . . .
Special Options and Accessories (OA’s)
Part Number
IA01
IA02
IA03
IA04
IA05
IA06
IA07
IA08
IA09
IA10
IA11
IA12
ID01
ID02
ID03
ID04
ID05
ID07
ID09
IF02
IGYZ*
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.AC-Volts Scaled RMS, 200/600V AC . . . . . . . . . . . . . . . . . . .
.AC-Volts Scaled RMS, 200mV/2V/20V AC . . . . . . . . . . . . . . .
.AC-mA Scaled RMS, 2/20/200mA AC . . . . . . . . . . . . . . . . . . .
.AC-Amps Scaled RMS, 0-1 Amp AC (0-100.00) . . . . . . . . . .
.AC-Amps Scaled RMS, 0-5 Amp AC (0-100.00) . . . . . . . . . .
.AC-Volts True RMS, 200/600V AC . . . . . . . . . . . . . . . . . . . . .
.AC-Volts True RMS, 200mV/2V/20V AC . . . . . . . . . . . . . . . . .
.AC-mA True RMS, 2/20/200mA AC . . . . . . . . . . . . . . . . . . . .
.AC-Amps True RMS, 0-1 Amp AC (0-100.00) . . . . . . . . . . .
.AC-Millivolt, Scaled RMS, 100mV AC . . . . . . . . . . . . . . . . . .
.AC-Amps True RMS, 0-5 Amp AC (0-100.00) . . . . . . . . . . .
.AC-Millivolt, True RMS, 100mV AC . . . . . . . . . . . . . . . . . . .
.DC-Volts, 2/20/200V/Custom w/24V DC Exc . . . . . . . . . . . . . .
.DC-Millivolt, 20/50/100/200mV DC w/24V DC Exc . . . . . . . . .
.DC-Milliamp, 2/20/200mA DC w/24V DC Exc . . . . . . . . . . . . .
.DC-Amps, 5A DC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
.DC-Volts 2/20/200/Custom V DC w/Offset and 24V Exc. . . . . .
.DC-Milliamp, 2/20/200mA DC w/Offset and 24V Exc . . . . . . . .
.DC-Amps, 1A DC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
.Line Frequency, 50-500VAC, 199.9Hz, or optional 400Hz . . . . .
.Universal Direct Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
.$35
.$35
.$40
.$40
.$40
.$55
.$55
.$55
.$55
.$55
.$55
.$55
.$25
.$35
.$25
.$50
.$45
.$35
.$50
.$45
.$100
.$35
.$45
.$45
.$15
.$40
.$40
.$40
.$45
.$55
.$55
.$40
.$40
.$40
.$40
.$40
.$40
.$40
.$40
Description
SPECIAL OPTIONS (Specify Input & Req. Reading)
CR-CHANGE . . . .Calibrated Range Change to another Standard Range . .
CS-X/45 . . . . . . .Custom Scaling within any Stnd. or Custom Selectable Range
CSR-X/45 . . . . . .Custom Selectable Range Installation or Modification .
CSS-X/45 . . . . . .Custom Special Scaling beyond the Standard Range . .
List
.$5
.$10
.$30
.$40
ACCESSORIES (Specify Serial # for Custom Artwork Installation)
75-DMT96X24 . . .Side Slide Brackets (2 pc) - extra set, extra strength .$2
75-DBBZ96X24 . . .Extra Black Bezel for 96x24mm Case . . . . . . . . . . . .$2
ART-FS-S/D/C . . .NRC for artwork & set-up Faceplate/Desc/Co.Logo . .$75
ART-FS-S/D . . . . .NRC for artwork & set-up Faceplate/Desc . . . . . . . . .$35
ART-FS-001 . . . . .Install Custom Faceplate per meter - 1 color . . . . . . .$10
93-PLUG2P-DP . . .Extra Screw Terminal Conn., 2 Pin Power Plug . . . . . .$2
93-PLUG2P-DR . . .Extra Screw Terminal Conn., 2 Pin Plug . . . . . . . . . . .$2
93-PLUG3P-DR . . .Extra Screw Terminal Conn., 3 Pin Plug . . . . . . . . . . .$3
93-PLUG4P-DR . . .Extra Screw Terminal Conn., 4 Pin Plug . . . . . . . . . . .$4
DN.CAS96X24L . . .Complete 96x24mm Case with bezel . . . . . . . . . . . . .$20
Many other options and accessories are available. See full price list for more details.
*View the IG- Ordering Code on page 5 to determine the value for Y & Z (IGAZ to IGKZ)
Prices subject to change without notice.
WARRANTY
USER’S RESPONSIBILITY
Texmate warrants that its products are free from defects in material and workmanship under
normal use and service for a period of one year from date of shipment. Texmate’s obligations
under this warranty are limited to replacement or repair, at its option, at its factory, of any of the
products which shall, within the applicable period after shipment, be returned to Texmate’s facility, transportation charges pre-paid, and which are, after examination, disclosed to the satisfaction of Texmate to be thus defective. The warranty shall not apply to any equipment which
shall have been repaired or altered, except by Texmate, or which shall have been subjected to
misuse, negligence, or accident. In no case shall Texmate’s liability exceed the original purchase price. The aforementioned provisions do not extend the original warranty period of any
product which has been either repaired or replaced by Texmate.
We are pleased to offer suggestions on the use of our various products either by way of printed matter or through direct contact with our sales/application engineering staff. However, since
we have no control over the use of our products once they are shipped, NO WARRANTY
WHETHER OF MERCHANTABILITY, FITNESS FOR PURPOSE, OR OTHERWISE is made
beyond the repair, replacement, or refund of purchase price at the sole discretion of Texmate.
Users shall determine the suitability of the product for the intended application before using,
and the users assume all risk and liability whatsoever in connection therewith, regardless of any
of our suggestions or statements as to application or construction. In no event shall Texmate’s
liability, in law or otherwise, be in excess of the purchase price of the product.
Texmate cannot assume responsibility for any circuitry described. No circuit patent or software
licenses are implied. Texmate reserves the right to change circuitry, operating software, specifications, and prices without notice at any time.
For product details visit www.texmate.com
Local Distributor Address
995 Park Center Drive • Vista, CA 92081-8397
Tel: 1-760-598-9899 • USA 1-800-839-6283 • That’s 1-800-TEXMATE
Fax: 1-760-598-9828 • Email: [email protected] • Web: www.texmate.com
Texmate has facilities in Japan, New Zealand, Taiwan, and Thailand. We also have
authorized distributors throughout the USA and in 28 other countries.
Page 8
Texmate, Inc. Tel. (760) 598-9899 • www.texmate.com
Copyright © 2003 Texmate Inc. All Rights Reserved.
7/15/03 BX-45 Data Sheet (BX2)