Download 450U-E Wireless Ethernet Modem Install Guide

Survey
yes no Was this document useful for you?
   Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Document related concepts

Amplifier wikipedia , lookup

Oscilloscope wikipedia , lookup

Telecommunications engineering wikipedia , lookup

Telecommunication wikipedia , lookup

Multimeter wikipedia , lookup

Coupon-eligible converter box wikipedia , lookup

Oscilloscope history wikipedia , lookup

Power MOSFET wikipedia , lookup

Power electronics wikipedia , lookup

Immunity-aware programming wikipedia , lookup

Crossbar switch wikipedia , lookup

Analog-to-digital converter wikipedia , lookup

CMOS wikipedia , lookup

Operational amplifier wikipedia , lookup

Valve RF amplifier wikipedia , lookup

Schmitt trigger wikipedia , lookup

Index of electronics articles wikipedia , lookup

Transistor–transistor logic wikipedia , lookup

Switched-mode power supply wikipedia , lookup

Opto-isolator wikipedia , lookup

Rectiverter wikipedia , lookup

Transcript
450U-E WIRELESS ETHERNET MODEM AND DEVICE SERVER INSTALLATION GUIDE
POWER SUPPLY WIRING
USB Ports for Configuration
and Firmware Upgrades
RS-485 Resistor
Termination Switch
Factory
Default Switch
RJ-45 Ethernet RS-232
Connection
Connection
Power Supply
RS-485 Connection
Analog Input
Digital Input/Outputs
NOTES This equipment is suitable for use in Class I Division 2 groups A, B, C and D hazardous
locations, or nonhazardous locations only.
• ALL connections must be SELV (Safety Extra Low Voltage <50 Vac and <120 Vdc).
• M4 GND screw on rear of module must be connected to the main earth/GND as close as
practicable to the unit.
• Module power supply -Ve terminal is not isolated from earth/GND.
• The Modem enclosure contains aluminum and is considered to constitute a potential risk
of ignition by impact or friction, and this must be taken into account during installation.
• If the Modem is installed in a hazardous environment, it must be installed in an enclosure
that maintains an ingress protection rating of IP54 and meets the enclosure requirements
of EN 50014 or EN60079-0.
• If the Modem is installed in a hazardous environment, coaxial cable shall be installed in a
metallic conduit, per the US National Electrical Code (NEC) or NFPA.
• Consult the User Manual for details on connecting to the USB Ethernet port located under
the cover on the front panel.
WARNING Explosion hazard! Do not disconnect equipment while the circuit is live or unless
the area is known to be free of ignitable concentrations.
Substitution of any component may impair suitability for Class 1 Division 2.
• Connect M4 screw terminal on rear of
module to ground as close as possible
to the module.
• Beware of ground loops.
9–30 Vdc
Supply
2A Fuse or
Circuit Breaker
ANALOG/DIGITAL INPUT-OUTPUT WIRING
Voltage Free
Contact
Max 30 Vdc
0.5A
Digital Input (Switch)
NPN Transistor
Output (PLC)
Digital Output
Externally Powered
4–20 mA Sensor
Digital Input (Transistor)
©2013 Cooper Bussmann
www.cooperbussmann.com/wirelessresources
10/16Page 1 of 2Version 1.0
Analog Input
450U-E WIRELESS ETHERNET MODEM AND DEVICE SERVER INSTALLATION GUIDE
RS-485 CONNECTIONS
ANTENNA INSTALLATION
RS-485 Resistor
Termination Switch
RS-232 CONNECTIONS
PCs
PCs, Data Loggers
©2013 Cooper Bussmann
www.cooperbussmann.com/wirelessresources
10/16Page 2 of 2Version 1.0