* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download FWJ-(20-30)A14F
War of the currents wikipedia , lookup
Electrical engineering wikipedia , lookup
Pulse-width modulation wikipedia , lookup
Power inverter wikipedia , lookup
Electric power system wikipedia , lookup
Audio power wikipedia , lookup
Immunity-aware programming wikipedia , lookup
Ground (electricity) wikipedia , lookup
Stepper motor wikipedia , lookup
Resistive opto-isolator wikipedia , lookup
Power factor wikipedia , lookup
Mercury-arc valve wikipedia , lookup
Electrification wikipedia , lookup
Electrical ballast wikipedia , lookup
Current source wikipedia , lookup
Three-phase electric power wikipedia , lookup
Voltage regulator wikipedia , lookup
Electrical substation wikipedia , lookup
Opto-isolator wikipedia , lookup
Power MOSFET wikipedia , lookup
Power engineering wikipedia , lookup
Variable-frequency drive wikipedia , lookup
Power electronics wikipedia , lookup
Switched-mode power supply wikipedia , lookup
History of electric power transmission wikipedia , lookup
Surge protector wikipedia , lookup
Buck converter wikipedia , lookup
Stray voltage wikipedia , lookup
Voltage optimisation wikipedia , lookup
Bussmann ® Ferrule 20-30A FWJ 1000V Electrical Characteristics I2t (A2S) Rated Current Clearing RMS-Amps Pre-arc at 1000V Size ® Ordering Information Watts Loss Part Number Carton Qty. Carton Weight (kg) 9 11 14 FWJ-20A14F FWJ-25A14F FWJ-30A14F 10 0.300 20 25 220 14 ≈ 67mm 25 33 350 (·Ω¡§∑) 30 52 450 n Interrupting rating 25kA RMS Symmetrical. n Watts loss provided at rated current. n (800 Vdc/Interrupting rating 20kA) U.L. Recognized. Dimensions Curves Figure Number BIF # Fig. 1 35785315 1 kg = 2.2 lbs. 1 lb = 0.45 kg Dimensions Fig. 1: 20-30 Amp Range 66.7 (2.626") 14.5 (0.571") 15.9 (0.625") Dimension in mm. 1mm = 0.0394∑ 1∑ = 25.4mm Electrical Characteristics Total Clearing I2t The total clearing I2t at rated voltage and at power factor of 15% are given in the electrical characteristics. For other voltages, the clearing I2t is found by multiplying by correction factor, K , given as a function of applied working voltage, E g , (RMS). Arc Voltage This curve gives the peak arc voltage, U L , which may appear across the fuse during its operation as a function of the applied working voltage, E g , (RMS) at a power factor of 15%. 1.5 2000 K 1.0 Kp 0.8 UL 1.0 Power Losses Watts loss at rated current is given in the electrical characteristics. The curve allows the calculation of the power losses at load currents lower than the rated current . The correction factor, K p , is given as a function of the RMS load current, Ib , in % of the rated current . 1600 0.6 0.5 1200 0.4 0.5 0.3 800 0.3 0.2 0.2 400 Eg Eg 0.15 680 800 1000 200 600 1000 1400 1800 0.1 30 40 50 Ib 60 70 80 90 100% The only controlled copy of this BIF document is the electronic read-only version located on the Bussmann Network Drive. All other copies of this document are by definition uncontrolled. This bulletin is intended to clearly present comprehensive product data and provide technical information that will help the end user with design applications. Bussmann reserves the right, without notice, to change design or construction of any products and to discontinue or limit distribution of any products. Bussmann also reserves the right to change or update, without notice, any technical information contained in this bulletin. Once a product has been selected, it should be tested by the user in all possible applications. 7-18-01 SB01191 Form No. FWJ 1000 Page 1 of 1 BIF Doc #720028