Download Catalogue PDF (1,705 KB)

Survey
yes no Was this document useful for you?
   Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Document related concepts

Ohm's law wikipedia , lookup

Resistive opto-isolator wikipedia , lookup

Current source wikipedia , lookup

Mercury-arc valve wikipedia , lookup

Portable appliance testing wikipedia , lookup

Variable-frequency drive wikipedia , lookup

Rectifier wikipedia , lookup

Switch wikipedia , lookup

Voltage optimisation wikipedia , lookup

History of electric power transmission wikipedia , lookup

Light switch wikipedia , lookup

Fault tolerance wikipedia , lookup

Circuit breaker wikipedia , lookup

Surge protector wikipedia , lookup

Switched-mode power supply wikipedia , lookup

Stray voltage wikipedia , lookup

Alternating current wikipedia , lookup

Buck converter wikipedia , lookup

Mains electricity wikipedia , lookup

Opto-isolator wikipedia , lookup

Electrical substation wikipedia , lookup

Electrical wiring in the United Kingdom wikipedia , lookup

Earthing system wikipedia , lookup

Transcript
GAS INSULATED SWITCHGEAR
MODEL
HS-X (TYPE1)
12kV/24kV
Advanced environmentally
friendly switchgear
A-199-4-C6718-E HQ1209 Printed in Japan (MDOC)
Revised Publication, effective Sep. 2012.
Superseding Publication, A-199-4-C6718-D of Mar. 2009.
Specifications are subject to change without notice.
Advanced environmentally friendly switchgear
Mitsubishi Electric Corporation has designed and manufactured a substantial amount of
high quality switchgear all over the world. This vast experience was drawn on to produce
the next generation of advanced environmentally friendly switchgear, the ”HS-X”.
H
igh reliability - Years of trouble free operation
The reliability has been increased even further by the application of an
electro-magnetic vacuum circuit breaker (VCB) operating mechanism. With
fewer parts†2 the chances of failures occurring have decreased.
F
†2 35% less parts than conventional Mitsubishi Electric spring VCB operating mechanism.
lexible design - Suitable for many applications
S
Designed so that several orientations of cable terminations
(power and control) entry are available, makes it one of the
most flexible switchgear on the market.
afe Design - Ensures operator’s safety
In the event of an internal arc, any arc fault gas will be directed
away from the operator (through the top of the panel). With the
benefit of GIS design concepts, there are no live parts exposed
inside the panel which ensures utmost safety for operators.
S
imple installation - Quick and easy
No gas processing is required during site installation and
commissioning, which simplifies planning and reduces time
required for installation, and maintains the high quality of
the switchgear during transportation.
L
ow maintenance - Reduction of maintenance costs
The circuit breaker’s advanced electro-magnetic operation does
not require maintenance for over 15 years†3. The circuit breaker
and disconnecting / earthing switch are hermetically sealed in a
tank and together with the application of original anti-oxidation
grease to the moving parts of the disconnecting / earthing switch
enable smooth long-term operation for 15 years or more.
†3 Under normal operation conditions according to IEC standard.
U
ser friendly - Simple operation
CONTENTS
A simple layout of the operating mechanisms and mimic
diagram at the front of the panel leads to straightforward
operation. Additionally this reduces the chance of maloperation.
RATINGS
03
FEATURES
04
COMPONENTS
05
ompact size - Space saving
SAFE OPERATION & USER FRIENDLY
07
The weight and required space for installation has been
reduced †1 by the use of solid insulated busbars and the
HIGH RELIABILITY AND COMPACT SIZE
09
SWITCHGEAR ARRANGEMENT
11
FOUNDATION DRAWING
13
STANDARD & OPTIONAL SPECIFICATIONS
13
STANDARD ACCESSORIES
14
OPTION
14
C
application of a multi-function relay.
†1 46% less space compared to Mitsubishi Electric existing GIS of the same ratings
E
nergy saving - Reduction of running costs
The use of an electro-magnetic VCB operating mechanism reduces the required operation energy by
approximately 80% when compared to conventional
motor-spring operating mechanisms.
01
MITSUBISHI HS-X
E
nvironmentally friendly - SF6 Free
Mitsubishi Electric Co. is the world leader in establishing compressed
dry air insulation technology based on the design and development
technologies of conventional SF6 switchgear. Under dry, clean and
compression, air has good insulation properties, which makes it
ideally suitable to be used as insulation for gas insulated switchgear.
(Dry air insulation is an option)
MITSUBISHI HS-X
02
RATINGS
FEATURES
GENERAL
Standard
Rated voltage
Rated frequency
Rated normal current of main busbars
Rated insulation levels
IEC
LIWV
AC (1min)
Rated short-time withstand current
Rated duration of short-time current
Insulation medium
Rated gas pressure †1
kV
Hz
A
kV (peak)
kV (rms)
kA
sec
MPa-abs
Alarm gas pressure †1
MPa-abs
62271-200†1
12
24
50 / 60
630 / 1250
75
28
125
50
25
3
SF6 / Dry air†2
SF6
Dry air
SF6
Dry air
: 0.13
: 0.17
: 0.12
: 0.15
SF6
Dry air
SF6
Dry air
Multi-function relay
Moduled control circuit
Solid insulated busbar
Mitsubishi “MP” relays are installed as
standard. This relay combines protection, measurement and control
functions into one compact flush door
mounted unit. Current transformer
ratios are adjustable in combination
with the use of wide range current
transformers.
Control devices and equipment and
wiring are moduled. Functions are
readily interchangeable and the
enclosure of live parts provides a
high level of reliability.
The busbar is independently solidly
insulated for each phase, which eliminates any chance of phase-to-phase
faults. Also no gas processing is required
during site installation or maintenance.
: 0.13
: 0.17
: 0.12
: 0.15
BUS
†1 : The application standard is for 630A rating with dry air only. Others are IEC 60298.
†2 : Insulation medium of dry air is an option and for 630A rating only.
VACUUM CIRCUIT BREAKER (VCB)
Standard
Rated voltage
Type of circuit breaker
Rated short-circuit breaking current
Rated short-circuit making current
Break time
Rated operating sequence
Type of operating mechanism
Test terminal (Option)
IEC 622271-100
kV
kA
kA
cycles
12
24
Vacuum
25
63
3
O-1min-CO-3min-CO, O-0.3sec-CO-3min-CO, CO-15sec-CO
Electro-magnetic
ES
DS
VCB
A
kA
Gas vessel
The circuit breaker, disconnecting
and earthing switch are hermetically sealed in the maintenance free
dry air or SF6 insulated gas vessel.
The operating mechanism is simple
making it user friendly and reduces
the chances of mal-operation.
IEC 60129
630 / 1250
25
Manual †3
Manual
Three position switch
The earthing switch is unified with
the disconnecting switch.
Three position disconnecting
switch operating mechanism
DISCONNECTING/EARTHING SWITCH (DS/ES)
Standard
Rated normal current (disconnecting switch)
Rated short-time withstand current
Operating mechanism (disconnecting switch)
Operating mechanism (earthing switch)
There is no need to disturb the cable
terminations in order to carry out high
voltage testing of cables. (Maximum
applicable voltage : DC20kV / 10min)
†3 : Motor operation is an option.
WIDE RANGE CURRENT TRANSFORMER (CT)
IEC 60044-1
2000 / 5 or 600 / 5
5
10P20 / Class 1.0
Standard
CT ratio †4
Burden
Accuracy class
A
VA
†4 : Transformer ratio can be adjusted in combination with MP multi-function relay.
EARTHED VOLTAGE TRANSFORMER (EVT)
IEC 60044-2
Standard
Rated primary voltage
Rated secondary voltage
Rated tertiary voltage †5
Burden (secondary / tertiary) †5
Accuracy class
V
V
V
VA
11000
22000
110
110, 190
50 / 50
1.0 / 3P
Electro-magnetic VCB
operating mechanism
A reduced number of parts increases
the reliability of the VCB. Also, a
reduction in the required energy to
operate the VCB is achieved.
Plug-in termination (Option)
Wide range current transformer
Reduces the time required for cable
termination work. Also cable voltage withstand testing can be easily
performed by using a test terminal
without removing the cables.
The ratios of the current transformers
can be changed without physically
changing the CTs in combination with
multi-function relay (MP), providing
great flexibility.
Test terminal
†5 : Tertiary winding is an option.
LIGHTNING ARRESTOR (LA)
IEEE 386 or DIN 47 636
Standard
Type
Rated voltage
Normal discharge current
03
MITSUBISHI HS-X
IEC 60099-4
Zinc oxide
kV
kA
12
24
5, 10
Cable
MITSUBISHI HS-X
04
COMPONENTS
Vacuum circuit breaker (VCB)
Three position switch
The VCB’s operating mechanism is an electro-magnetic type. As
An earthing switch is unified with the disconnecting
switch. The earthing switch is manually operated
however the disconnecting switch is manually operated
with motor operation as an option.
the name implies, the electro-magnetic type of VCB is driven by
electro-magnets. The electrical power required is supplied by a
capacitor (see below for auxiliary power requirements).
The electro-magnetic VCB has the following features:
Main circuit close position
■ Reliability increase
Disconnecting position
Earthing position
Main busbar
The structure of the electro-magnetic operating mechanism is
more simple than that of the motor-spring operating mechanism,
and required 35% less parts which significantly reduces the
chances of failures.
q
■ Maintenance reduction
The main busbar is independently and solidly insulated
for each phase. During main busbar connection no gas
processing is required. Since the surface of the insulation
is earth screened, there is no chance of phase-to-phase
short circuits.
Earth screen
Connection piece
Bushing for bus
With the use of an electro-magnetic operating mechanism,
there is no need for major maintenance for over 15 years.†1
z
¥
†1 : The service life of the capacitor should be 15 years under normal operation conditions.
v
■ Energy required reduction
Cross section of busbar
r
u
w
s
x
t
The required energy is reduced by 80% (when compared to
y
conventional motor-spring operating mechanisms) by minimizing
DC power supply
Solidly insulated bus
Conductor
Plug in cable termination (Option)
Plug in type cable terminations make cable connection
work simple and efficient. IEEE or DIN standard plug in
type terminations are applicable.
Test
terminal
operation energy loss. Furthermore, noise during VCB operation
q “Close” push button
has been significantly reduced.
IEEE 386 or DIN 47 636
r “Open” push button
: Out of scope
s “Close” charge completion lamp(LED)
JP Pat No. 4230246
Others, five patents in Japan and twenty-three patents in eight
t “Open” charge completion lamp(LED)
different countries (CN, HK, TW, KR, SG, DE, FR, US).
u Auxiliary power / control circuit
v Electro-magnetic operating mechanism
w “Closing” capacitor
x “Opening” capacitor
y Operation / indication unit
Cable
Arc pressure relief device
BUS
Pressure relief devices are applicable for safety operation to prevent human injury in case of internal arc
accidents.
Relief flap
Arc flap
DS
z
¥ Vaccum circuit breaker (VCB)
FRONT
VCB
CABLE
Auxiliary power
Equipment
VCB
Electrical-magnet
operation
Capacitor charging current
DS
(For motor
operation)
Control power
Capacity
I(A)
T(S)
DC 110V
(Open)I=5A,T=0.02 Sec
(Close)I=0.4A,T=3.5 Sec
Motor operation current
0.2(ms)
3(s)
Multi-function relay and wide range current transformer
Flush mounted type multi-function relay “MP” covers protection, control, measurement and communication functions. In
combination with the wide range CT, the CT ratios can be readily changed without the replacement of CTs.
Other voltages are
available as an option.
DC 110V, 0.5A
I2(A)
Remarks
I1(A)
DC 110V : I1=5A
I2=1.5A
Option
■ Protection
Overcurrent (50/51),
Directional ground fault (67G),
Ground fault (51G),
Undervoltage (27),
Overvoltage (59),
Ground fault overvoltage (64)
■ Control
CB control / Lock out / Remote operation.
■ Measurement
A, V, W, Wh, Var, Varh, Hz, PF
■ Communication
Modbus®RTU†1, CC-link, CDL protocols are
available.
†1 : Modbus® is a registered trademark of Schneider Electric SA.
05
MITSUBISHI HS-X
MITSUBISHI HS-X
06
SAFE OPERATION & USER FRIENDLY
Safe operation
The surface of the solid insulation on the main busbars, voltage transformer, cable termination and gas vessel which is earthed,
A-2 The VCB mechanism provides simple operation from closed to opened condition by the use of a manual trip handle as
described below.
prevents electric shocks even when accidental contact occurs while the panel is energized.
Earth shield
(Carbon film)
Busbar (Copper)
Insulation material
(Silicon rubber)
V
Open the cover
0
Attach the adaptor
Apply the handle
Pull down the handle
d
Earth screen busbar
B. Disconnecting / earthing switch
■ A three position switch ensures the DS and ES are not operated at the
same time.
User friendly
The mimic diagram provides easy understanding of the VCB and DS / ES conditions. Mitsubishi HS-X provides easy operation and
■ By adopting a testing terminal on the ES provides the capability of
performing cable withstand testing without removing the main
power cables. ( Maximum applicable voltage: DC 20V 10min (SF6) )
prevents mal-operation by having a simple to understand and conveniently located (around eye level) operating mechanisms.
Test terminal
q DS/ES shutter operation selector
q
r
s
r ES operation mechanism with shutter
x
y
v
w
■ The DS / ES can easily operate by using the operation handle
t ES condition indicator
u VCB manual tripping mechanism with cover
v Manual closing button with cover
t
u
s DS operation mechanism with shutter
■ The shutter operation key ensures that the DS / ES are operated
separately and also provides a locking function.
z
{
w Capacitor charged lamp
x Gas densimeter
y DS condition indicator
z VCB operation counter
|
}
{ VCB condition indicator
| Manual tripping button
} Capacitor discharging button
DS / ES operation
A. Vacuum Circuit breaker
A-1 HS-X adopts an advanced electro-magnetic operation mechanism and
utilizes a capacitor to drive trip and close operation.
For maintenance purposes, the discharging method is simply two steps
as described below.
1 ) Turn off the control power (for trip / close).
2 ) Push the discharging button} on the VCB operation mechanism until
the capacitor charged lampw turns off.
C. Installation of busbar & cable termination
Capacitor
for close
■ HS-X switchgear busbar are designed in a individual phase arrangement that prevents faults between phases.
Capacitor
for trip
■ Since solid insulation busbars are used, no gas processing is required
during installation and commissioning.
■ Since the cable terminations are standard IEEE / DIN size, installation is
very easy.
Busbar arrangement
07
MITSUBISHI HS-X
MITSUBISHI HS-X
08
HIGH RELIABILITY AND COMPACT SIZE
Dry air insulation
In response to the increasing concern for the environment,
24kV
2
the conventional SF6. As demonstrated by the graph on the
400
Others, two patents in Japan.
1020
MAINTENANCE SPACE †2
Dry-air
1.5
N2
Space reduction of
MAINTENANCE SPACE †2
55%
including
maintenance space
1
FRONT
FRONT
Condition: Lightning impulse voltage 1.2 / 50μs
Unit : mm
†2 : Maintenance space required is recommendation only.
0.5
GWP
0
1
23900
H S-X
1000
1650
PREVIOUS
EXISTING MITSUBISHI
MITSUBISHI GIS
GIS
SF6
Global warming potential (GWP)
Insulation medium
Dry air
CO2
SF6
Needle
100mm
1500
JP Pat No. 4545362
Breakdown voltage V / Vo (pu)
for medium voltage gas insulated switchgear.
6000
φ200mm
right, under compression, dry air has insulating characteristics
that are more than sufficient to use as an insulated medium
36kV
50
switchgear using dry air as the insulated medium instead of
7000
700
700
Mitsubishi Electric Co. has designed the HS-X range of
0.0
0.05 0.07
0.1
0.15
0.2
Pressure (MPa)
Insulation characteristics of compressed air
(Vo : Breakdown voltage of air at 0.0Mpa)
Mitsubishi long life grease
A specially developed long life grease is applied to the moving
Oxidation stability test - Oxidation of grease is the main
parts of the operating mechanism of the Disconnecting /
deterioration factor. As the graph above demonstrates
Earthing switch. This “Mitsubishi“ grease has been thoroughly
Mitsubishi grease show very little oxidation (the pressure of
tested to guarantee smooth lubrication for over 15 years
oxygen remains unchanged throughout the test).
without the need for reapplication, as demonstrated by the
test data results graphed below. The required maintenance
IR spectrum of Mitsubishi grease - The IR spectrums of
time required is reduced dramatically.
Mitsubishi grease before and after the oxidation stability test
are nearly identical, proving the grease characteristics remain
the same even after many years after it has been put into use.
Compact size
HS-X range
sealed vessel. The graph on the right demonstrates that the
0.6
2.5
Bentonite-based grease
A
conversely the insulation clearance distance can be decreased
HS-X requires 55% less †1 installation space when compared
This allows for it to be installed in
many locations where space is limited.
†1 : Based on 10 panel arrangement and maintenance space.
a
Breakdown voltage V / Vo (pu)
to less than half) of that when no barriers are used.
B
Barrier
2
d
Needle
A : φ100mm
B : 300mm×300mm
(t=3mm)
d : 100mm
1.5
1
countries (CN, TW, KR, BR).
0.5
20.
0
Lithium soap-based grease
0.8
0.1
0
50
100
150
Barrier position (a/d)
10
20
MITSUBISHI HS-X
30
Equivalent period under room temperature (Years)
Oxidation stability test
Insulation characteristics of air with insulating barrier
09
200
1
0
(Vo : Breakdown voltage without barrier)
1000
500
Mass of grease : 72g
Heating time(hr)
0.6
1500
Wave numbers(cm-1)
IR spectrum of Mitsubishi grease
Temperature : 150℃
0.2
0.0
0.4
3000 2000
0.3
0
0.2
After oxidation stability test
40.
0.4
0.5
0
60.
Lithium soap-based grease
Condition: Lightning impulse voltage 1.2 / 50μs
JP Pat No. 4146249
Others, one patent in Japan and four patents in four different
Pressure of oxygen(MPa)
breakdown voltage can be increased to more than double (or
80.
Coefficient of friction
suitably positioned insulating barriers within the hermetically
Before oxidation stability test
Mitsubishi grease
Fluoride-based grease
0.7
Transmittance(%)
The compact size of the switchgear is achieved by the use of
to its previous model.
100.0
0.8
0.3
0.2
0.1
Mitsubishi grease
-20
0
20
80
Temperature(℃)
Coefficient of friction under low and high temperatures
Coefficient of friction - The coefficient of friction of Mitsubishi
grease remains consistently low, both under low and high temperature conditions.
MITSUBISHI HS-X
10
SWITCHGEAR ARRANGEMENT
Typical key single line & section view
Typical single line diagram
Incoming panel
Outgoing panel
DS/ES
TR
Typical key single
line
TR
Bus section panel
DS/ES
VCB
Bus EVT / LA panel
DS/ES
RL
VCB
VCB
CT
3×LA
CT
VD
3×EVT
BUS
VD
3×LA
ES
CT
BUS
BUS
BUS
BUS
VD
3×LA
CT
Section view
ES
DS
VCB
ES
DS
VCB
DS
RL
VCB
LA
VCB
VCB
DS / ES
3×EVT
EVT
DS / ES
3×EVT
ES
ES
DS / ES
VCB
12 /
24kV
DS / ES
DS / ES
DS / ES
DS / ES
DS / ES
DS / ES
VCB
VCB
VCB
VCB
VCB
VCB
Note
CT
CT
CT
CT
CT
600
1020
2000
500
85
Width (mm)
Depth (mm)
Height (mm)
Weight (kg)
Heat value (J/S)
600
1020
2000
500
85
600
1300
2000
500
25
600×2
1020
2000
800
85
■ ♦: Insulator (gas barrier)
■ Heat values indicated are for 630A.
■ For outdoor panels the depth and height are increased by 250mm and 350mm respectively.
Other section view (flexible design)
Cable entry
from top
(Indoor type only)
Incoming panel
with EVT / LA
Incoming panel
with bus EVT
(Indoor type only)
Incoming panel
from bus duct
Bus EVT / LA panel
with ES
Bus
3×EVT
DS/ES
DS/ES
Panel layout of above single line diagram
DS/ES
ES
DS/ES
Typical key single
line
VCB
VCB
3×LA
3×EVT
CT
CT
VD
VD
BUS
BUS
3×LA
VCB
VCB
3×EVT
CT
BUS
BUS
ES DS
ES
BUS
DS /
ES
DS /
ES
DS /
ES
DS /
ES
ES
DS /
ES
ES
DS /
ES
DS /
ES
DS /
ES
DS /
ES
VCB
CT
VCB
CT
VCB
CT
VCB
CT
3×EVT
VCB
3×EVT
VCB
VCB
VCB
VCB
CT
CT
CT
CT
ES DS
Section view
VCB
3×LA
3×LA
ES DS
VCB
VCB
VCB
LA
LA
EVT
VD
VD
ES DS
EVT
E.BUS
600
600
600
600
600
600
600
600
600
600
600
600
1020
Width (mm)
Depth (mm)
12 /
24kV Height (mm)
Weight (kg)
Heat value (J/S)
Note
11
MITSUBISHI HS-X
600
1300
2000
500
85
600
1300
2000
550
85
600
1020
2260
550
85
†1
†1
2000
†1
†1
600
1300
2000
550
25
■ ♦: Insulator (gas barrier)
■ Heat values indicated are for 630A.
■ For outdoor panels the depth and height are increased by 250mm and 350mm respectively.
■ Other type configration please contact MITSUBISHI ELECTRIC CO.
†1 : For these specification please contact MITSUBISHI ELECTRIC Co.
MITSUBISHI HS-X
12
FOUNDATION DRAWING
STANDARD ACCESSORIES
Front side space for maintenance
LV compartment key
290 (440)
80
100 (250)
55 (90)
1020 †1 (1300)
325
Rear space 50
350 (90)
Front door
50 (75)
100
1000
Cover
FRONT
Test plug
Foundation bolt†2
600
50 (75)
400
400
Floor
FRONT
55
Embedded channel base†2
350
Hole for control cable
700
1020
Hole for main circuit cable
and earthing cable
Cross-section view
Foundation bolt hole size 20
Shutter operation key
Side space
†1 : In case of top or rear cable entry, panel depth is requited 1300mm.
(
) means size of outdoor use.
DS / ES operation handle
†2 : Embedded channel base and foundation bolt are not supplied.
STANDARD & OPTIONAL SPECIFICATIONS
VCB manual trip handle
Gas adapter
Panel
Panel thickness
Gas vessel
Insulation medium
Degree of
protection
Painting
Panel wiring
Cable
Auxiliary
equipment
Multi-function
relay
DS
Test terminal
Item
Installation location
Enclosure (not including gas vessel)
Annual gas leakage rate
Low voltage compartment
Bus bar chamber
Gas Vessel
Operating mechanism compartment
Cable chamber
Partitions between compartments
All surfaces except operating
mechanism compartment
Operating mechanism compartment
Type
General control circuit
Size
VT, CT secondary circuits
Color General
VT and CT secondary circuits
Color
Grounding
Main circuit cable entry
Main circuit cable terminal
Main circuit cable gland
Control cable entry
Space heater
Terminal block for control circuits
Name plates
Operation
At ES terminal
Standard specification
Indoor
More than 2.0 mm
Less than 0.5% weight per year
SF6
IP2X
IP2X
IP65
IP2X
IP2X
IP2X
Munsell 5Y7/1
Optional specification
Outdoor
Dry air †1
IP51
IP51
IP51
IP51
IP4X
Specified color
Munsell 5PB3.5/5
600V PVC insulated
1.25 mm2 or more
2.0 mm2
Yellow
Yellow
Green
Front bottom
Not supplied
Not supplied
Front bottom
Not supplied
Screw type
Acrylic plate
MP + Wide range CT
Specified color
Specified type
Specified size
Specified size
Specified color
Specified color
Specified color
Rear top or bottom
Specified type, size & specification
Specified type, size & specification
Front top
Specified type & specification
Specified type
Laminated plates or stainless steel
Specified type
Manual
Not supplied
Motor
Supplied
OPTION
CBM (Condition Based Maintenance) System
CBM system is the maintenance system based on the equipment condition. It has two advanced points compared
to Time Based Maintenance system requires periodical maintenance.
1. Prevention of accidents by early detection of
malfunction
2. Reduction of life cycle cost
Example of maintenance Item
Without
CBM function
With
CBM function
Major
inspection
Major
inspection
Minor
inspection
CBM function unit
Main periodical inspection item
Switchgear
Condition
based
monitoring
(CBM)
Minor
inspection
Major
inspection
Minor
inspection
Visual
inspection
Visual
inspection
†1 : Insulation medium of dry air is for 630A rating only.
Part
Class
VCB
Items automatically
monitored by CBM
Insulation,
gas pressure †2
• Partial discharge monitoring †1
Vacuum interrupter
(contact erosion,degree of vacuum)
• Analysis of driving current
• Partial discharge monitoring †1
Electro-magnetic
operating mechanism
• Analysis of driving current
Controller
Control circuit for drive
• Charge voltage of capacitor
• Analysis of driving current
Control P.C.B.
• CPU fault self-monitoring
Driving capacitor
• Time properties of discharging
†1 : There are cases when partial discharge monitoring cannot be applied, in some cases of
noise level from outside system of panel.
†2 : Gas pressure is monitored with gas densimeter.
Regarding periodical maintenance
For conditions not monitored by the CBM function, periodical inspections equivalent to those conducted
conventionally, including field,minor and major inspections, are required.
JP Pat No. 4682046
Others, two patents in Japan and thirteen patents in seven different countries (CN, HK, TW, KR, US, TH, DE).
13