Download FILMTEC Membranes Water Chemistry and Pretreatment: Summary of Pretreatment Options

Survey
yes no Was this document useful for you?
   Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Document related concepts

Infection control wikipedia , lookup

Traveler's diarrhea wikipedia , lookup

Portable water purification wikipedia , lookup

Biocide wikipedia , lookup

Triclocarban wikipedia , lookup

Transcript
Lenntech
Tech Manual Excerpt
[email protected] Tel. +31-152-610-900
www.lenntech.com Fax. +31-152-616-289
FILMTEC Membranes
Water Chemistry and Pretreatment: Summary of Pretreatment Options
Summary of
Pretreatment
Options
Table 2.11 summarizes the pretreatment options when specific risks for scaling and fouling
are present. It is a quick reference for “possible” and “very effective” methods. A combination
of “possible” methods may also be “very effective”.
Table 2.11 Pretreatment options for scaling and fouling
Pretreatment
Acid addition
Scale inhibitor antifoulant
Softening with IX
Dealkalization with IX
Lime softening
Preventive cleaning
Adjustment of operation
parameter
Media filtration
Oxidation filtration
In-line coagulation
Coagulation-flocculation
Microfiltration/Ultrafiltration
Cartridge filtration
Chlorination
Dechlorination
Shock treatment
Preventive biocidal
treatment
GAC filtration
○Possible
Page 1 of 2
CaCO3
●
○
●
○
○
○
CaSO4
BaSO4
SrSO4
CaF2
SiO2
●
●
○
○
●
●
○
○
●
●
○
○
●
●
○
○
○
○
○
○
○
○
○
○
SDI
Fe
○
○
○
○
○
○
○
○
○
●
●
○
○
●
○
○
○
○
Al
○
Bacteria Oxid. agents Org. matter
○
○
○
●
○
○
●
○
○
○
○
○
○
○
●
●
○
○
●
●
○
○
○
●
●
●Very effective
* Trademark of The Dow Chemical Company
Form No. 609-02044-504
Lenntech
[email protected] Tel. +31-152-610-900
www.lenntech.com Fax. +31-152-616-289
Notice: The use of this product in and of itself does not necessarily guarantee the removal of cysts and pathogens from water.
Effective cyst and pathogen reduction is dependent on the complete system design and on the operation and maintenance of
the system.
Notice: No freedom from any patent owned by Seller or others is to be inferred. Because use conditions and applicable laws
may differ from one location to another and may change with time, Customer is responsible for determining whether products
and the information in this document are appropriate for Customer’s use and for ensuring that Customer’s workplace and
disposal practices are in compliance with applicable laws and other governmental enactments. Seller assumes no obligation or
liability for the information in this document. NO WARRANTIES ARE GIVEN; ALL IMPLIED WARRANTIES OF
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ARE EXPRESSLY EXCLUDED.
Page 2 of 2
*Trademark of The Dow Chemical Company
Form No. 609-02044-504