AUXCARD
AUXILIARY CONTACTS OPTION BOARD
INTRODUCTION
The Auxiliary Contacts Option Board has both normally-open and
normally-closed contacts that actuate when the door is opening, closing
and when the operator is powered down.
When the operator is powered up, the following contact outputs are
available:
DEFAULT OPERATION
While opening:
open 2 - 1 closed
(OPEN or A' relay contacts)
open 2 - 3 opened
While closing:
close 2 - 1 opened
(CLOSE or B' relay contacts)
close 2 - 3 closed
Operator powered down:
open 2 - 1 opened
open 2 - 3 closed
close 2 - 1 closed
close 2 - 3 opened
open 2 - 1 opened
open 2 - 3 closed
close 2 - 1 closed
close 2 - 3 opened
N4 and N4X operators
While opening or closing:
Open Terminals not available
for Auxiliary use
close 2 - 1 opened
close 2 - 3 closed
NOTE: Power for devices controlled by the auxiliary contacts to be
supplied from an external source.
Green Lights
K2
C5
D2
TB2
TB1
R7
R1
C7 R2
+
C2
R10
1
D1
CLOSE
(B' relay)
Close Terminals
Terminals
C1
J1
10
C6
R8
1
CLOSE
R3
2
3
R9
Q1
OPEN
relay)
Open (A'
Terminals
Terminals
OPEN
R5
K1
R4
1
2
C3
Q2
INSTALLATION
Connect wires to terminals as needed. Use copper wire only #14 AWG
maximum. Plug option board into either slot at the end of the logic board.
Reconnect power to operator. The green light(s) on the option board will
turn on if the board is seated properly and the power is on.
Insert PCB Board into
either slot
CAUTION
To avoid damage to relays:
• DO NOT exceed maximum contact rating of 10A at 240 Vac.
• NOT applicable for incandescent loads.
• Conduit, wiring and connectors should be sized and installed
per the national electrical code.
PROGRAM REMOTE CONTROL TO TURN ON/OFF AND
AUXILIARY CONTACT
Either of the auxiliary contacts on the card can be programmed to be
turned on or off by use of a remote control. Either one or both contacts
may be programmed independently. This can be used for controlling
accessories such as a fan or light that is within the voltage and operating
specifications of the relay contact. The user must release and reactivate
the remote control to switch state again. The RADIO LED will remain on
while a valid command is being received. This programmed feature will
override the default operation.
NOTE: Remote control of relays not available for N4 or N4X logic
operators.
3
AUX CONTACTS
D3 R6 C4
D4
To avoid SERIOUS personal INJURY or DEATH from electrocution:
• Disconnect electrical power to operator BEFORE proceeding.
PROGRAM
Operator powered on and
door not in motion:
+5V +24V
WARNING
Auxiliary Contacts
Option Board
AUXILIARY RELAY A OR B PROGRAMMING PROCEDURE
INPUT
RESULT
DISPLAY
Press and release
the radio button.
Enter the RADIO
function learning mode.
The radio LED
will turn on solid.
Press and release the
MRT button on the
logic board to program
relay A or press and
release the MID SET
button on the logic
board to program
relay B.
Enter AUX. relay (A) or (B)
function learning mode.
This depends on weather
MRT or MID SET was
pressed.
The radio LED
flashes rapidly
then remains on
solid.
Press and release the
remote control button
to be programmed.
The remote control
button will be
programmed to
the function.
The radio LED
flashes rapidly and
then turns off.
Press and release the
radio button.
The learning mode
will be exited.
The radio LED
flashes rapidly
then turns off.
Commercial door operator accessory for use only with LiftMaster® solid
state commercial door operators.
Logic Board
01-31099E
© 2010, The Chamberlain Group, Inc.
All Rights Reserved
For more information:
www.devancocanada.com
or call toll free at 855-931-3334
HOW TO ORDER
REPAIR PARTS
DEVANCO CANADA
19192 HAY ROAD, UNIT Q
SUMMERSTOWN, ON K0C 2E0
TOLL FREE: 855-931-3334
www.devancocanada.com
WHEN ORDERING REPAIR PARTS
PLEASE SUPPLY THE
FOLLOWING INFORMATION:
3 PART NUMBER
3 DESCRIPTION
3 MODEL NUMBER